Laboratory Glassware

All from one Hand – from the manufacturer

Laboratory glassware from the basic element to the finished equipment – from burettes to pycnometers – all our laboratory glass are produced according to the existing norms DIN/ISO/ASTM etc. On his sector, our product range includes more than 20,000 articles. We produce according to drawings individual items and assist you in problems with useful suggestions.

Generally, at witeg you can find all glassware used in the laboratory sector. As a manufacturer, we provide competitive solutions.

You can find anything suitable:

  • joint sizes ST 5 to ST71
  • thread sizes N8, GL14 to GL112
  • pipe diameters 3 mm to 320 mm
  • filter sizes 00 to 5
Close filters
293 From 311
No results were found for the filter!
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 007
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR. 300, RANGE cST 50-200 MM2/S, K: 0,25, NON-CAILBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 007 C
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR. 300, RANGE cST 50-200 MM2/S, K: 0,25, CAILBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 008
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR. 350, RANGE cST 100-500 MM2/S, K: 0,5, NON-CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 008 C
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR. 350, RANGE cST 100-500 MM2/S, K: 0,5, CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 009
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR. 400, RANGE cST 240 -1200 MM2/S, K: 1,2, NON-CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 009 C
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR. 400, RANGE cST 240 -1200 MM2/S, K: 1,2, CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 010
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR. 450, RANGE cST 500-2500 MM2/S, K: 2,5 NON-CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 010 C
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR. 450, RANGE cST 500-2500 MM2/S, K: 2,5 CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 011
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR.500, RANGE cST 1600-8000 MM2/S, K: 8,0; NON-CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 011 C
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR.500, RANGE cST 1600-8000 MM2/S, K: 8,0; CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 012
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR.600, RANGE cST 4000-20000 MM2/S, K: 20,0, NON-CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 012 C
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR.600, RANGE cST 4000-20000 MM2/S, K: 20,0, CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 013
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR.650, RANGE cST 9000-45000 MM2/S, K: 45,0, NON-CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 013 C
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR.650, RANGE cST 9000-45000 MM2/S, K: 45,0, CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 014
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR.700, RANGE cST 20 000-100000 MM2/S, K: 100,0, NON-CALIBRATED
VISCOMETERS CANNON UBBELOHDE A + DIL.B - 8 588 014 C
VISCOMETERS CANNON UBBELOHDE A + DIL.B
VISCOMETERS, CANNON UBBELOHDE A + DIL.B CAPILLARY NR.700, RANGE cST 20 000-100000 MM2/S, K: 100,0, CALIBRATED
VISCOMETERS L. 283 MM - 8 589 001
VISCOMETERS L. 283 MM
VISCOMETERS,L. 283 MM, F. TRANSP. LIQUIDS, CAPILLARY: 0, RANGE cST 0,3-1 MMS/S K: 0,001, NON-CALIBRATED; THREE TUBES
VISCOMETERS L. 283 MM - 8 589 002
VISCOMETERS L. 283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY:0C, RANGE cST 0,6-3 MMS/S K: 0,003 NON-CALIBRATED, THREE TUBES
VISCOMETERS L. 283 MM - 8 589 003
VISCOMETERS L. 283 MM
VISCOMETERS,L.283 MM F.TRANSP.LIQUIDS CAPILLARY:0B, RANGE cST 1 - 5 MMS/S K: 0,005 NON-CALIBRATED, THREE TUBES
VISCOMETERS CALIBRATED - 8 589 004
VISCOMETERS CALIBRATED
VISCOMETERS,CALIBR.,L.283 MM F.TRANSP.LIQU- IDS,CAP.1, 2-10 MM2/S,CONSTANT K 0,01 NON-CALIBRSTED, THREE TUBES
VISCOMETERS NON-CALIBRATED - 8 589 005
VISCOMETERS NON-CALIBRATED
VISCOMETERS, NON-CALIBR., L.283 MM,F.TRANSP.LIQUIDS, CAP.1C, 6-30 MM 2/S,CONSTANT K 0,03, THREE TUBES
VISCOMETERS L.283 MM - 8 589 006
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY:1B, RANGE cST 10 - 50 MMS/S K: 0,05 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 007
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY: 2, RANGE cST 20 - 100 MMS/S K: 0,1 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 008
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY: 2C, RANGE cST 60 - 300 MMS/S K: 0,3 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 009
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY:2B, RANGE cST 100-500 MMS/S K: 0,5 NON-CALIBRATED, THREE TUBES
293 From 311