Erlenmeyer flask, narrow neck, made of Quartz-Silica,
with rim, DIN 12380, 1000 ml, 136 x 200 mm
Erlenmeyer flask, narrow neck, made of Quartz-Silica,
with rim, DIN 12380, 2000 ml, 160 x 280 mm
Erlenmeyer flask, narrow neck, made of Quartz-Silica,
with rim, DIN 12380, 25 ml, 35 x 70 mm
Erlenmeyer flask, narrow neck, made of Quartz-Silica,
with rim, DIN 12380, 50 ml, 54 x 80 mm
Erlenmeyer flask, narrow neck, made of Quartz-Silica,
with rim, DIN 12380, 100 ml, 65 x 100 mm
Erlenmeyer flask, narrow neck, made of Quartz-Silica,
with rim, DIN 12380, 200 ml, 73 x 125 mm
Erlenmeyer flask, narrow neck, made of Quartz-Silica,
with rim, DIN 12380, 250 ml, 84 x 140 mm
Erlenmeyer flask, narrow neck, made of Quartz-Silica,
with rim, DIN 12380, 300 ml, 88 x 155 mm
Erlenmeyer flask, narrow neck, made of Quartz-Silica,
with rim, DIN 12380, 500 ml, 96 x 180 mm
Erlenmeyer flask, narrow neck, made of Quartz-Silica,
with rim, DIN 12380, 750 ml, 118 x 200 mm
Ideal for:
- for beaker 100 - 10.000 ml
Features:
- 100°C - 450°C
- nickel chrome heating element
- coil type: acid-resistant, long life time
- all kinds of beaker can be used (DURAN ®/Kimax/Pyrex/Iwaki)
- CE certified and unique serial number for tracing
Versions:
- built-in temperature controller
- built-in stirring & temperature controller
- without controller (separate controller needed)
Artikelliste
Order number | Model | Version | Height (inner) | Height (outer) | Diameter (outer) | Controller | Vessel diameter | Vessel capacity | Speed | Power consumption | Temperature range |
---|---|---|---|---|---|---|---|---|---|---|---|
DH.WHM12141 | WHM | with built-in temperature controller | 40 mm | 150 mm | Ø150 mm | integrated | Ø50 - 52 mm | 100 ml | 50 - 750 rpm | 80 W | 100°C - 450°C |
DH.WHM12142 | WHM | with built-in temperature controller | 65 mm | 150 mm | Ø150 mm | integrated | Ø68 - 70 mm | 250 ml | 50 - 750 rpm | 140 W | 100°C - 450°C |
DH.WHM12143 | WHM | with built-in temperature controller | 70 mm | 150 mm | Ø150 mm | integrated | Ø79 - 81 mm | 400 ml | 50 - 750 rpm | 240 W | 100°C - 450°C |
DH.WHM121431 | WHM | with built-in temperature controller | 75 mm | 150 mm | Ø150 mm | integrated | Ø76 - 78 mm | 400 ml | 50 - 750 rpm | 240 W | 100°C - 450°C |
DH.WHM12144 | WHM | with built-in temperature controller | 75 mm | 150 mm | Ø150 mm | integrated | Ø88 - 90 mm | 600 ml | 50 - 750 rpm | 240 W | 100°C - 450°C |
DH.WHM12145 | WHM | with built-in temperature controller | 90 mm | 175 mm | Ø200 mm | integrated | Ø98 - 100 mm | 800 ml | 50 - 750 rpm | 300 W | 100°C - 450°C |
DH.WHM12146 | WHM | with built-in temperature controller | 90 mm | 175 mm | Ø200 mm | integrated | Ø105 - 108 mm | 1000 ml | 50 - 750 rpm | 350 W | 100°C - 450°C |
DH.WHM12147 | WHM | with built-in temperature controller | 125 mm | 195 mm | Ø200 mm | integrated | Ø130 - 132 mm | 2000 ml | 50 - 750 rpm | 450 W | 100°C - 450°C |
DH.WHM12148 | WHM | with built-in temperature controller | 160 mm | 235 mm | Ø270 mm | integrated | Ø151 - 153 mm | 3000 ml | 50 - 750 rpm | 550 W | 100°C - 450°C |
DH.WHM121481 | WHM | with built-in temperature controller | 160 mm | 235 mm | Ø270 mm | integrated | Ø160 - 162 mm | 4000 ml | 50 - 750 rpm | 700 W | 100°C - 450°C |
DH.WHM12149 | WHM | with built-in temperature controller | 160 mm | 235 mm | Ø270 mm | integrated | Ø169 - 171 mm | 5000 ml | 50 - 750 rpm | 800 W | 100°C - 450°C |
DH.WHM121601 | WHM | with built-in stirring & temperature controller | 45 mm | 150 mm | Ø150 mm | integrated | Ø50 - 52 mm | 100 ml | 50 - 750 rpm | 80 W | 100°C - 450°C |
DH.WHM121602 | WHM | with built-in stirring & temperature controller | 70 mm | 150 mm | Ø150 mm | integrated | Ø68 - 70 mm | 250 ml | 50 - 750 rpm | 140 W | 100°C - 450°C |
DH.WHM121603 | WHM | with built-in stirring & temperature controller | 70 mm | 180 mm | Ø150 mm | integrated | Ø79 - 81 mm | 400 ml | 50 - 750 rpm | 240 W | 100°C - 450°C |
DH.WHM121604 | WHM | with built-in stirring & temperature controller | 70 mm | 180 mm | Ø150 mm | integrated | Ø76 - 78 mm | 400 ml | 50 - 750 rpm | 240 W | 100°C - 450°C |
DH.WHM121605 | WHM | with built-in stirring & temperature controller | 72 mm | 180 mm | Ø150 mm | integrated | Ø88 - 90 mm | 600 ml | 50 - 750 rpm | 240 W | 100°C - 450°C |
DH.WHM121606 | WHM | with built-in stirring & temperature controller | 105 mm | 195 mm | Ø200 mm | integrated | Ø105 - 108 mm | 1000 ml | 50 - 750 rpm | 350 W | 100°C - 450°C |
DH.WHM121607 | WHM | with built-in stirring & temperature controller | 140 mm | 195 mm | Ø200 mm | integrated | Ø130 - 132 mm | 2000 ml | 50 - 750 rpm | 450 W | 100°C - 450°C |
DH.WHM121608 | WHM | with built-in stirring & temperature controller | 140 mm | 235 mm | Ø270 mm | integrated | Ø151 - 153 mm | 3000 ml | 50 - 750 rpm | 550 W | 100°C - 450°C |
DH.WHM121609 | WHM | with built-in stirring & temperature controller | 170 mm | 270 mm | Ø325 mm | integrated | Ø160 - 162 mm | 4000 ml | 50 - 750 rpm | 700 W | 100°C - 450°C |
DH.WHM121610 | WHM | with built-in stirring & temperature controller | 170 mm | 270 mm | Ø325 mm | integrated | Ø169 - 171 mm | 5000 ml | 50 - 750 rpm | 800 W | 100°C - 450°C |
DH.WHM12170 | WHM | separate controller needed | 50 mm | 80 mm | Ø150 mm | WHM-C10A or WHM-C10D | Ø50 - 52 mm | 100 ml | 80 W | 100°C - 450°C | |
DH.WHM12171 | WHM | separate controller needed | 50 mm | 115 mm | Ø150 mm | WHM-C10A or WHM-C10D | Ø68 - 70 mm | 250 ml | 140 W | 100°C - 450°C | |
DH.WHM12172 | WHM | separate controller needed | 85 mm | 115 mm | Ø150 mm | WHM-C10A or WHM-C10D | Ø79 - 81 mm | 400 ml | 240 W | 100°C - 450°C | |
DH.WHM121721 | WHM | separate controller needed | 85 mm | 115 mm | Ø150 mm | WHM-C10A or WHM-C10D | Ø76 - 78 mm | 400 ml | 240 W | 100°C - 450°C | |
DH.WHM12173 | WHM | separate controller needed | 85 mm | 115 mm | Ø150 mm | WHM-C10A or WHM-C10D | Ø88 - 90 mm | 600 ml | 240 W | 100°C - 450°C | |
DH.WHM12174 | WHM | separate controller needed | 90 mm | 140 mm | Ø200 mm | WHM-C10A or WHM-C10D | Ø98 - 100 mm | 800 ml | 300 W | 100°C - 450°C | |
DH.WHM12175 | WHM | separate controller needed | 115 mm | 140 mm | Ø200 mm | WHM-C10A or WHM-C10D | Ø105 - 108 mm | 1000 ml | 350 W | 100°C - 450°C | |
DH.WHM12176 | WHM | separate controller needed | 140 mm | 155 mm | Ø200 mm | WHM-C10A or WHM-C10D | Ø130 - 132 mm | 2000 ml | 450 W | 100°C - 450°C | |
DH.WHM12177 | WHM | separate controller needed | 175 mm | 200 mm | Ø270 mm | WHM-C10A or WHM-C10D | Ø151 - 153 mm | 3000 ml | 550 W | 100°C - 450°C | |
DH.WHM12178 | WHM | separate controller needed | 175 mm | 200 mm | Ø270 mm | WHM-C10A or WHM-C10D | Ø160 - 162 mm | 4000 ml | 700 W | 100°C - 450°C | |
DH.WHM12179 | WHM | separate controller needed | 175 mm | 200 mm | Ø270 mm | WHM-C10A or WHM-C10D | Ø169 - 171 mm | 5000 ml | 800 W | 100°C - 450°C | |
DH.WHM121791 | WHM | separate controller needed; Mantle steel case - magnetic stirring is not available! | 245 mm | 270 mm | Ø325 mm | WHM-C10A or WHM-C10D | Ø216 - 219 mm | 10000 ml | 1400 W | 100°C - 450°C |
Ideal for:
- biotechnology, clinical, environmental, medical and food industry
Features:
- stainless steel wire basket (2 pcs. included) and pressure vessel
- powder-coated steel body
- top loading sterilizer for loading of large working volume
- thermal printer (record paper roll w58/ Ø 40 mm) (WAC-R)
- solid and liquid mode
- with casters for excellent mobility
- digital backlight LCD display
- digital timer function – delay time and operation time can be controlled
- built-in recorder: print sterilization data (only WAC-R)
- high-quality backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- overheat and over-current protection
- automatic over pressure release valve & heat-protective lid
- error alarm, power failure and temperature error
- water low level detection
- electronic door lock sensing system (locks the door over 80°C)
Controller:
- digital fuzzy controller (fully automatic)
Artikelliste
Order number | Model | Version | Height (inner) | Diameter (inner) | Width (Outer) | Length (outer) | Height (outer) | Ideal for | Pressure | Heating power | Capacity | Basket | Temperature range | Temperature accuracy | Packing size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WAC05047P | WAC-47 230 V | Lever type sliding door/ safety electronic door closing system, PED (pressure equipment directive) certification | 670 mm | Ø300 mm | 700 mm | 470 mm | 1080 mm | Biotechnology, clinical, environmental, medical and food industry | 1.2 kgf/ cm2 at 121°C / 2.0 kgf/ cm2 at 132°C, gauge: 0 - 3 kgf/ cm2 | 2000 W | 47 l | Ø270 x 240 mm | Room temperature + 5°C - 132°C | ±0.5°C to 121°C | 700 x 470 x 1,080 mm |
DH.WAC05060P | WAC-60 230 V | Lever type sliding door/ safety electronic door closing system, PED (pressure equipment directive) certification | 650 mm | Ø350 mm | 700 mm | 470 mm | 1080 mm | Biotechnology, clinical, environmental, medical and food industry | 1.2 kgf/ cm2 at 121°C / 2.0 kgf/ cm2 at 132°C, gauge: 0 - 3 kgf/ cm2 | 3000 W | 60 l | Ø320 x 240 mm | Room temperature + 5°C - 132°C | ±0.5°C to 121°C | 840 x 610 x 1252 mm |
DH.WAC07080P | WAC-80 3 Phase | Lever type sliding door/ safety electronic door closing system, PED (pressure equipment directive) certification | 650 mm | Ø400 mm | 810 mm | 580 mm | 1140 mm | Biotechnology, clinical, environmental, medical and food industry | 1.2 kgf/ cm2 at 121°C / 2.0 kgf/ cm2 at 132°C, gauge: 0 - 3 kgf/ cm2 | 2 x 2000 W | 80 l | Ø370 x 240 mm | Room temperature + 5°C - 132°C | ±0.5°C to 121°C | 950 x 730 x 1352 mm |
DH.WACR2047P | WAC-R47 230 V | Lever type sliding door/ safety electronic door closing system, recorder-type: built-in recorder printer, sterilization cycle data (date, temperature, pressure, time, error status, etc.), PED (pressure equipment directive) certification | 670 mm | Ø300 mm | 700 mm | 470 mm | 1080 mm | Biotechnology, clinical, environmental, medical and food industry | 1.2 kgf/ cm2 at 121°C / 2.0 kgf/ cm2 at 132°C, gauge: 0 - 3 kgf/ cm2 | 2000 W | 47 l | Ø270 x 240 mm | Room temperature + 5°C - 132°C | ±0.5°C to 121°C | 840 x 610 x 1252 mm |
DH.WACR2060P | WAC-R60 230 V | Lever type sliding door/ safety electronic door closing system, recorder-type: built-in recorder printer, sterilization cycle data (date, temperature, pressure, time, error status, etc.), PED (pressure equipment directive) certification | 650 mm | Ø350 mm | 700 mm | 470 mm | 1080 mm | Biotechnology, clinical, environmental, medical and food industry | 1.2 kgf/ cm2 at 121°C / 2.0 kgf/ cm2 at 132°C, gauge: 0 - 3 kgf/ cm2 | 3000 W | 60 l | Ø320 x 240 mm | Room temperature + 5°C - 132°C | ±0.5°C to 121°C | 840 x 610 x 1252 mm |
DH.WACR3080P | WAC-R80 3 Phase | Lever type sliding door/ safety electronic door closing system, recorder-type: built-in recorder printer, sterilization cycle data (date, temperature, pressure, time, error status, etc.), PED (pressure equipment directive) certification | 650 mm | Ø400 mm | 810 mm | 580 mm | 1140 mm | Biotechnology, clinical, environmental, medical and food industry | 1.2 kgf/ cm2 at 121°C / 2.0 kgf/ cm2 at 132°C, gauge: 0 - 3 kgf/ cm2 | 2 x 2000 W | 80 l | Ø370 x 240 mm | Room temperature + 5°C - 132°C | ±0.5°C to 121°C | 950 x 730 x 1352 mm |