The following products have been found matching your search "96d": 7

Or did you mean: 968 | 967 | 965 | 969 | 966 | 1 965 017 | 960 | 3 967 004
Close filters
  •  
    •  
    •  
from to
No results were found for the filter!
Dry bath (Incubator) HB-96D 2 blocks up to 150°C
Dry bath (Incubator) HB-96D 2 blocks up to 150°C

Ideal for:

  • enzyme reactions, inactivation of sera, incubation and other laboratory procedures
  • multifunctional dry block heater

 

Features:

  • user‘s self-compensation function to offset between real temperature and indicated temperature (±10.0°C)
  • unit made of stainless steel and powder-coated steel, block made of anodized aluminium
  • digital timer function
  • internal PPS bath ensures best insulation, block made of anodized aluminium
  • precise temperature control
  • block extraction tongs “BLE101” & block cover are included
  • storage function for the set values of temperature and timer
  • alarm function: error status and timer end
  • various kinds of blocks are offered (optional)
  • dual block and 2 molded heater (300W)
  • backlight LCD display
  • CE certified and unique serial number for tracing

 

Safety mechanism:

  • locking mode
  • overheat and over-current protection
  • sensor error detection

 

Controller:

  • dual digital fuzzy controller with Jog-Shuttle-switch

 

Artikelliste

Order number Model Version Width (inner) Length (inner) Height (inner) Width (Outer) Length (outer) Height (outer) Heating time Power consumption Temperature range Temperature accuracy Packing size Sensor
DH.WHB00198 HB-96D unit 230 V 90 mm 120 mm 60 mm 250 mm 285 mm 155 mm approx. 5°C/min 600 W Room temperature +5°C to 150°C ±0.1°C at 37°C, ±0.2°C to 90°C, ±0.4°C at 135°C 400 x 270 x 200 mm Temperature sensor PT100
DH.WHB00199 HB-96D set 230 V incl. 2 standard blocks with 48 holes for 1.5/2 ml centrifuge tubes 90 mm 120 mm 60 mm 250 mm 285 mm 155 mm approx. 5°C/min 600 W Room temperature +5°C to 150°C ±0.1°C at 37°C, ±0.2°C to 90°C, ±0.4°C at 135°C 400 x 270 x 200 mm Temperature sensor PT100
Density areometer 1,900-1,960:0,001 without thermometer - 8 561 023
Density areometer 1,900-1,960:0,001 without thermometer

Density areometer, 1,900-1,960:0,001, without thermometer, Length 160 mm

Density areometer 1,960-2,020:0,001 without thermometer - 8 561 024
Density areometer 1,960-2,020:0,001 without thermometer

Density areometer, 1,960-2,020:0,001, without thermometer, Length 160 mm

Precision Areometer 0,940-0,960:0,0002 - 8 585 018
Precision Areometer 0,940-0,960:0,0002

Precision Areometer, Type L20, Range 0,940-0,960:0,0002, DIN 12791, without Thermometer, 20°C

Precision Areometer 0,960-0,980:0,0002 - 8 585 019
Precision Areometer 0,960-0,980:0,0002

Precision Areometer, Type L20, Range 0,960-0,980:0,0002, DIN 12791, without Thermometer, 20°C

Precision Areometer 0,940-0,960:0,0002 - 8 586 018
Precision Areometer 0,940-0,960:0,0002

Precision Areometer, Type L20, Range 0,940-0,960:0,0002, DIN 12785, with Thermometer, 20°C

Precision Areometer 0,960-0,980:0,0002 - 8 586 019
Precision Areometer 0,960-0,980:0,0002

Precision Areometer, Type L20, Range 0,960-0,980:0,0002, DIN 12785, with Thermometer, 20°C