No results were found for the filter!
Filter for half mask protection class A1 - 7 302 071
Filter for half mask, protection class A1, acc. to EN 141 and EN 143, Case = 2 pcs.
Ultrasonic cleaner WUC-A 1,2 - 22 Liter 40kHz analog with lid
Ideal for:
- cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency
Features:
- made of stainless steel, finished surface
- convenient preset function of heating and timer
- HF frequency 40 kHz
- bottom-mounted drain valve (WUC-A10H and WUC-A22H)
- maximum 30 minutes cleaning time
- CE certified and unique serial number for tracing
Controller:
- analog controller for timer, temperature and output control
Artikelliste
Order number | Model | Version | Ideal for | Drain valve | Vessel diameter | Heating power | Capacity | Power consumption | Temperature range | Ultrasound | Packing size |
---|---|---|---|---|---|---|---|---|---|---|---|
DH.WUC.A01H | WUC-A01H 230 V | with flip switch | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 150 x 135 x 60 mm | 86 W | 1.2 l | 158 W | ambient or 65°C fix | HF-peak-out: 72 W | 200 x 200 x 190 mm | |
DH.WUC.A02H | WUC-A02H 230 V | with flip switch | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 150 x 135 x 100 mm | 86 W | 1.8 l | 161 W | ambient or 65°C fix | HF-peak-out: 75 W | 200 x 200 x 240 mm | |
DH.WUC.A03H | WUC-A03H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 240 x 140 x 100 mm | 172 W | 3.3 l | 296 W | Ambient to 85°C | HF-peak-out: 124 W | 320 x 200 x 290 mm | ||
DH.WUC.A06H | WUC-A06H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 290 x 150 x 150 mm | 172 W | 6 l | 340 W | Ambient to 85°C | HF-peak-out: 168 W | 370 x 220 x 350 mm | ||
DH.WUC.A10H | WUC-A10H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 1/2“ NPT | 290 x 240 x 150 mm | 258 W | 10 l | 523 W | Ambient to 85°C | HF-peak-out: 265 W | 434 x 320 x 360 mm | |
DH.WUC.A22H | WUC-A22H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 1/2“ NPT | 500 x 300 x 150 mm | 275 W | 22 l | 654 W | Ambient to 85°C | HF-peak-out: 379 W | 640 x 380 x 370 mm |
Moisture analyzer WBA-110M 0,01-110g - DH.WBA110M
Ideal for:
- measuring the percentage of moisture content
Features:
- Ø 90 mm weighing plate, stainless steel chamber and load cell sensor
- external calibration
- built-in RS232C & USB port for printer
- up to 15 values storable
- halogen light heating and PT 100 temperature sensor
- temperature and time selectable
- 100 g calibration weight and 10 sample plates included
- 3 displays after drying:
- humidity (%) - reduce weight of liquid
- dry mass (%) - weight of solid
- ATRO (%) - 100 - 999%
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- default and auto lock present working mode
Freeze dryer Accessories
Artikelliste
Order number | Model | Version | Length (outer) | Height (outer) | Diameter (outer) | Material | Ideal for | Capacity | Accessories |
---|---|---|---|---|---|---|---|---|---|
DH.GL12041 | Flasks | 80 mm | Ø40 | made of DURAN® tubing | FD-8 | 40 ml | |||
DH.GL12042 | Flasks | 120 mm | Ø40 | made of DURAN® tubing | FD-8 | 80 ml | |||
DH.GL12043 | Flasks | 100 mm | Ø65 | made of DURAN® tubing | FD-8 | 200 ml | |||
DH.GL12044 | Flasks | 140 mm | Ø65 | made of DURAN® tubing | FD-8 | 300 ml | |||
DH.GL12045 | Flasks | 125 mm | Ø90 | made of DURAN® tubing | FD-8 | 500 ml | |||
DH.GL12046 | Flasks | 165 mm | Ø90 | made of DURAN® tubing | FD-8 | 700 ml | |||
DH.GL12047 | Flasks | 225 mm | Ø90 | made of DURAN® tubing | FD-8 | 1000 ml | |||
DH.CA1002 | Table car | 2 stages | FD-8 and pump | ||||||
DH.FRD01041 | T-type manifold | for 3 Liter, with 12 connections | FD-8 | 3/4“ Vacuum handle valve, incl. 12 silicone stoppers | |||||
DH.FRD01051 | Dry chamber | with 8 connections | Acryl | FD-8 | 3/4“ Vacuum handle valve, incl. 8 silicone stoppers | ||||
DH.FRD01061 | Rack | 3 stages | Stainless steel | ||||||
DH.FRD03010 | Vacuum handle valve | 3/4“ | Neoprene rubber and PP | FD-8 | |||||
DH.GL28091 | Tube adapter | 3/4“ | 80 mm | Ø19 | Glass | FD-8 | |||
DH.GL28092 | Tube adapter | 3/4“, bent-type | 80 mm | Ø19 | Glass | FD-8 | |||
DH.FRD04010 | Tube adapter | holes 1/2" and 3/4“, bent | 80 mm | PP | FD-8 | ||||
DH.FRD05010 | Microtube platform head | 1/2" | Silicone | 40/80 ml flasks | |||||
DH.FRD05020 | Microtube platform head | 3/4“ | Silicone | 200/300 ml flasks | |||||
DH.FRD05030 | Microtube platform head | 3/4“ | Silicone | 500/700/1000 ml flasks |
Balance Printer, spare parter rolls and sample plates
Artikelliste
Order number | Model | Version | Diameter (outer) | Ideal for | Packaging unit | Connections | Accessories | Sensor |
---|---|---|---|---|---|---|---|---|
DH.WBA100P | WBA-100 printer | for paper rolls | WBA balance | RS232 connection | 1 paper roll included | Temperature sensor PT100 | ||
DH.WBA0084 | Spare paper roll | WBA-100 | 5 pcs. | |||||
DH.WBA420P | WBA-420 printer | for label paper rolls | WBA balance | RS232 connection | 1 label paper roll included | |||
DH.WBA0771 | Spare label paper roll | WBA-420 | 5 pcs. | |||||
DH.WBA0005 | Sample plates | Ø90 mm | WBA balance | 10 pcs. |
Recovery head 1 FA 12 - 1 965 003
Recovery head, 1 FA 12, 1 FA 10, 1 GL 18/6