The following products have been found matching your search "digitaler": 74
The digital burette TITREX is ideal for a fast and sensitive titration “drop by drop”. One instrument simulates all volumes up to 99.99 ml. Moreover, titration is possible without any loss of reagent! From air-purging, necessary for a precise titration, to disassembly of the burette in the end of the titration – the reagent, that is not needed for the titration flows back into the bottle! TITREX‘s accuracy and precision are of highest quality. Our error ranges are better than those required by ISO 8655-3. The memory function allows saving of up to 1000 values, which can be transferred to a PC and read using the included software.
Your advantage at a glance:
- high quality precision instrument, made in Germany
- highest accuracy and precision, our error ranges are better than the DIN EN ISO 8655-3 requirements
- resistant against most acids and alkalis
- exclusive instrument with 0% loss of reagent - air-purging and draining within a closed circuit
- 360° rotatable valve block for your added safety
- two-in- one instrument: dosing & titration
- covers the complete volume range up to 50 ml when used as a dispenser and up to 99.99 ml when used as a burette
- easy and precise volume setting
- vertical valves: no sedimentation, no contamination
- 100 % drip-free by turning the cannula at 180°
- no transcriptions errors due to automatic value storage and the possibility of
- transferring values to a PC via RS232 interface (USB adapter optional available)
- calibration: standard with water of 20°C
- software enables saving the next calibration date
- recalibration for liquids of different viscosities possible e.g. determination of acid content in milk
- easy to dismantle and to clean, valve block autoclavable at 121°C
- automatic power-cut-off after three minutes
- including NiMH 1,2V 2100mAh battery
- individual certificate, CE label and serial number
- DE-M marked according to the German calibration law
Artikelliste
Order number | Model | Version | Autoclavable | Thread | Systematic errors ISO | Systematic errors witeg | Random errors ISO | Random errors witeg | Volume | Volume adjustment | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|
5 497 050 | TITREX premium | premium | Valve block at 121°C | GL45 | ±0.1 ml | ±0.03 ml | ≤0.05 ml | ≤0.01 ml | 0 - 50 ml | Handwheels (left and right) | incl. TITREXSOFT and RS232 interface cord |
5 497 050 E | TITREX eco | eco | Valve block at 121°C | GL45 | ±0.1 ml | ±0.1 ml | ≤0.05 ml | ≤0.05 ml | 0 - 50 ml | Handwheels (left and right) | TITREXSOFT and RS232 interface cord not included in the scope of supply |
5 497 150 | TITREX fine adjustment | finely adjustable | Valve block at 121°C | GL45 | ±0.1 ml | ±0.03 ml | ≤0.05 ml | ≤0.01 ml | 0 - 50 ml | Handwheels (left and right) | incl. TITREXSOFT and RS232 interface cord |
Ideal for:
- cleaning to remove dirt, grease, waxes and oil from all laboratory instruments by ultrasonic frequency
Features:
- convenient preset function of heating and timer
- HF frequency 40 kHz
- temperature range from ambient to 80°C
- bottom-mounted drain valve (WUC-D10H and WUC-D22H)
- maximum 60 minutes cleaning time
- microprocessor control: timer, temperature and output control
- FND display
- CE certified and unique serial number for tracing
- WUC-D03H model includes degassing function for very strong cleansing
Controller:
- digital controller for timer, temperature and output control
Artikelliste
Order number | Model | Ideal for | Drain valve | Vessel diameter | Heating power | Capacity | Power consumption | Temperature range | Ultrasound | Packing size |
---|---|---|---|---|---|---|---|---|---|---|
DH.WUC.D03H | WUC-D03H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 240 x 140 x 100 mm | 172 W | 3.3 l | 290 W | Ambient to 80°C | HF-peak-out: 100 W | 320 x 200 x 290 mm | |
DH.WUC.D06H | WUC-D06H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 290 x 150 x 150 mm | 172 W | 6 l | 425 W | Ambient to 80°C | HF-peak-out: 253 W | 360 x 220 x 350 mm | |
DH.WUC.D10H | WUC-D10H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 1/2“ NPT | 290 x 240 x 150 mm | 258 W | 10 l | 665 W | Ambient to 80°C | HF-peak-out: 407 W | 440 x 320 x 360 mm |
DH.WUC.D22H | WUC-D22H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 1/2“ NPT | 500 x 300 x 150 mm | 344 W | 22 l | 872 W | Ambient to 80°C | HF-peak-out: 528 W | 640 x 380 x 370 mm |
Ideal for:
- cleaning to remove dirt, grease, waxes and oil from al laboratory instruments by ultrasonic frequency
Features:
- remote generator: power control and timer function with LCD display
- BTL sonicator installed: robust and stable running
- sweep function can realize complete cleaning by the dispersion of ultrasound
- auto optimization of frequency as various water level and temperature
- foot switch control
- temperature range from ambient to 105°C
- full set with lid, foot switch and generator
- drain mounted in the bottom
- HF frequency 40 kHz
- maximum 99 minutes cleaning time
- CE certified and unique serial number for tracing
Controller:
- digital remote controller for timer, temperature and output control
Artikelliste
Order number | Model | Ideal for | Vessel diameter | Heating power | Capacity | Power consumption | Temperature range | Ultrasound | Packing size |
---|---|---|---|---|---|---|---|---|---|
DH.WUC.N30H | WUC-N30H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | Outer: 480 x 380 x 400 mm, Inner: 400 x 300 x 250 mm | 990 W | 30 l | 4694 W, generator 600 W | Ambient to 105°C | HF-peak-out: 704 W | 620 x 520 x 640 mm |
DH.WUC.N47H | WUC-N47H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | Outer: 530 x 430 x 450 mm, Inner: 450 x 350 x 300 mm | 990 W | 47 l | 1980 W, generator 900 W | Ambient to 105°C | HF-peak-out: 990 W | 670 x 570 x 710 mm |
DH.WUC.N60H | WUC-N60H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | Outer: 530 x 430 x 450 mm, Inner: 500 x 400 x 300 mm | 990 W | 60 l | 2200 W, generator 1200 W | Ambient to 105°C | HF-peak-out: 1210 W | 720 x 620 x 710 mm |
DH.WUC.N74H | WUC-N74H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | Outer: 580 x 480 x 450 mm, Inner: 550 x 450 x 300 mm | 990 W | 74 l | 2420 W, generator 1500 W | Ambient to 105°C | HF-peak-out: 1430 W | 770 x 670 x 710 mm |
- controlled burning duration 1sec up to 120 min.
- firing time display
- multi-lingual, joystick navigation, duration display, manual mode / floor switch
- automatic stop when not in use
- overheat protection
- exact economic flame adjustment
- stable flame even at intense airflow
- flame and ignition monitoring
- angle adjustment
Artikelliste
Order number | Model | Version | Width (Outer) | Length (outer) | Height (outer) | Material | Ideal for | Connections |
---|---|---|---|---|---|---|---|---|
7 401 200 | Digital gas burner | 160 mm | 128 mm | 85 mm | ||||
7 401 215 | Safety gas tubing | 0.75 m | Schuett Phoenix II standard, allgas | |||||
7 401 216 | Safety gas tubing | 0.5 m | Schuett Phoenix II standard, Propane / Butane | Thread connections | ||||
7 401 217 | Safety gas tubing | 2.0 m | Schuett Phoenix II standard, Propane / Butane | Thread connections | ||||
7 401 218 | Safety gas tubing | 1.0 m | Schuett Phoenix II standard, allgas | Standard connection 1/2“ for gas outlet (TAE) | ||||
7 401 219 | Safety gas tubing | 2.0 m | Schuett Phoenix II standard, allgas | Standard connection 1/2“ for gas outlet (TAE) | ||||
7 401 211 | Adapter | with pressure reducing valve | Schuett Phoenix II standard, CV 360 Butane cartridges | |||||
7 401 212 | Adapter | with pressure reducing valve | Schuett Phoenix II standard, C 206 Butane cartridges and safety gas tubing 0.5 m | |||||
7 401 213 | Glasss splatter guard | Glass | Schuett Phoenix II standard, C 206 Butane cartridges and safety gas tubing 0.5 m | |||||
7 401 214 | Flame shield | Stainless steel | Schuett Phoenix II standard |
- Digital stopwatch:
- 59 min. 59 sec. 1/100
- start/stop, addition, split, reset, ABS housing, lanyard
- Counter/timer with alarm:
- timer up to 99 min. 99 sec.
- count-down 99 min. 99 sec.
- with magnet and clip
- Counter / timer with alarm and clock:
- timer up to 99 min. 59 sec. 1/100
- count-down 99 min. 59 sec. 1/100
- with magnet and clip
- Counter / timer with alarm and clock:
- timer up to 23 h 59 min. 59 sec.
- count-down 23 h 59 min. 59 sec.
- with magnet and clip
- Timer (mechanical):
- 0 - 60 min.
Artikelliste
Order number | Model | Version | Housing material |
---|---|---|---|
8 484 150 | Digital stopwatch | Timer 59 min. 59 sec. 1/100: start/stop, adition, split, reset, lanyard | ABS |
8 484 160 | Timer with alarm | Timer 99 min. 59 sec., count-down, with magnet and clip | |
8 484 200 | Timer with alarm and clock | Timer 99 min. 59 sec. 1/100, count-down, clock, with magnet and clip | |
7 425 100 | Timer with alarm and clock | Timer 23 hrs. 59 min. 59 sec. 1/100, count-down, clock, with magnet and clip | |
8 480 112 | Timer (mechanical) | 0-60 min. |
Ideal for:
- laboratory vacuum control
- rotary evaporation
- vacuum concentration and distillation
Features:
-
automatic evaporation mode: avoid shocks and maintain the optimal vacuum level. You can start and release it at any tim.
-
removable remote control panel with magnetic holder
-
magnetic valve control, compatible with most vacuum systems
-
made of chemical-resistant materials for high durability
-
intuitive and modular settings
-
up to 10 steps per program can be set
-
can be operated with thick laboratory gloves
Safety mechanism:
- overpressure protection
- error message
Artikelliste
Order number | Model | Bore | Width (Outer) | Height (outer) | Color | Form | Thread | Synthetic coating | Material | Ideal for | Screw cap | Volume |
---|---|---|---|---|---|---|---|---|---|---|---|---|
5 372 128 | Minispensor bottle | Ø51 mm | 100 mm | Amber stained | round | GL28 | Yes | Amber soda-lime glass | Minispensor | 100 ml | ||
5 372 101 | Witospensor bottle | 50 mm | 125 mm | Amber stained | GL32 | Yes | Amber soda-lime glass | Labmax, Titrex | 100 ml | |||
5 372 025 | Witospensor bottle | 65 mm | 160 mm | Amber stained | GL32 | Yes | Amber soda-lime glass | Labmax, Titrex | 250 ml | |||
5 372 050 | Witospensor bottle | 80 mm | 195 mm | Amber stained | GL32 | Yes | Amber soda-lime glass | Labmax, Titrex | 500 ml | |||
5 372 100 | Witospensor bottle | 95 mm | 230 mm | Amber stained | GL45 | Yes | Amber soda-lime glass | Labmax, Titrex | 1000 ml | |||
5 372 250 | Witospensor bottle | Ø140 mm | 230 mm | Amber stained | round | GL45 | Yes | Amber soda-lime glass | Labmax, Titrex | 2500 ml | ||
5 372 300 | Witospensor bottle | 11 mm | Ø136 mm | 265 mm | Amber stained | round | GL45 + GL18 with bore | Yes | Borosilicate glass 3.3 | Labmax, Titrex | Yes (2) | 2000 ml |
Artikelliste
Order number | Model | Version | Diameter (inner) | Length (outer) | Diameter (outer) | Material | Ideal for |
---|---|---|---|---|---|---|---|
5 375 002 | Flexible discharge tube | Coiled, with protective sleeve | Ø2 mm | Ø3 mm | FEP/PP | Labmax 2.5 - 10 ml | |
5 375 012 | Flexible discharge tube | Coiled, with protective sleeve | Ø4 mm | Ø6 mm | FEP/PP | Labmax 25 - 100 ml, Titrex | |
5 375 003 | Discharge tube | Bent, with protective sleeve | 80 mm | FEP/PP | Labmax 2.5 - 10 ml | ||
5 375 004 | Discharge tube | Bent, with protective sleeve | 120 mm | FEP/PP | Labmax 25 - 100 ml | ||
5 497 400 | Discharge tube | Bent with fine tip and protective sleeve | 120 mm | FEP/PP | Titrex | ||
5 372 755 | Discharge tube | Bent with fine tip and protective sleeve | FEP/PP | Minispensor 100 - 2000 µl |
Artikelliste
Order number | Model | Version | Diameter (inner) | Length (outer) | Material | Ideal for |
---|---|---|---|---|---|---|
5 375 000 TK | Filling tube | Telescope-tube | Ø4 mm | 170 - 330 mm | FEP | Labmax 2.5 - 10 ml |
5 375 001 TK | Filling tube | Telescope-tube | Ø6 mm | 170 - 330 mm | FEP | Labmax 25 - 100 ml, Titrex |
5 375 000 TK 140 | Filling tube | Telescope-tube | 70 - 140 mm | FEP | Labmax 2.5 - 10 ml | |
5 375 000 TK 240 | Filling tube | Telescope-tube | 125 - 140 mm | FEP | Labmax 2.5 - 10 ml | |
5 375 000 TK 350 | Filling tube | Telescope-tube | 195 - 350 mm | FEP | Labmax 2.5 - 10 ml | |
5 375 000 TK 480 | Filling tube | Telescope-tube | 250-480 mm | FEP | Labmax 2.5 - 10 ml | |
5 375 001 TK 480 | Filling tube | Telescope-tube | 250-480 mm | FEP | Labmax 25 - 100 ml, Titrex | |
5 375 000 N 310 | Filling tube | Ø5 mm | 310 mm | FEP | Labmax 2.5 - 10 ml | |
5 375 000 N 390 | Filling tube | Ø5 mm | 390 mm | FEP | Labmax 2.5 - 10 ml | |
5 375 001 310 | Filling tube | Ø7 mm | 310 mm | FEP | Labmax 25 - 100 ml, Titrex | |
5 375 001 390 | Filling tube | Ø7 mm | 390 mm | FEP | Labmax 25 - 100 ml, Titrex | |
5 375 004 M | Filling tube | FEP | Minispensor 50 - 100 µl | |||
5 375 014 | Filling tube | FEP | Minispensor 100 - 2000 µl |
Artikelliste
Order number | Model | Thread | Material | Ideal for |
---|---|---|---|---|
5 377 022 | Thread adapter | A22 | PP | Labmax, Titrex, Minispensor |
5 377 025 | Thread adapter | A25 | PP | Labmax, Titrex, Minispensor |
5 377 028 | Thread adapter | A28 | PP | Labmax, Titrex, Minispensor |
5 377 030 | Thread adapter | A30 | PP | Labmax, Titrex, Minispensor |
5 377 032 | Thread adapter | A32/A28 | PP | Minispensor |
5 377 038 | Thread adapter | A38 | PP | Labmax, Titrex, Minispensor |
5 377 040 | Thread adapter | A40 | PP | Labmax, Titrex, Minispensor |
5 497 600 | Thread adapter | A45/A32 | PP | Labmax, Titrex |
5 377 045 | Thread adapter | A45 | PP | Labmax, Titrex, Minispensor |
Artikelliste
Order number | Model | Thread | Cone (ST) | Material | Ideal for |
---|---|---|---|---|---|
0 550 029 | Joint adapters | GL32 | ST 19/26 | Borosilicate glass 3.3 | Labmax, Titrex, Minispensor |
0 550 030 | Joint adapters | GL32 | ST 24/29 | Borosilicate glass 3.3 | Labmax, Titrex, Minispensor |
0 550 031 | Joint adapters | GL32 | ST 29/32 | Borosilicate glass 3.3 | Labmax, Titrex, Minispensor |
0 550 040 | Joint adapters | GL45 | ST 29/32 | Borosilicate glass 3.3 | Labmax, Titrex, Minispensor |
0 550 041 | Joint adapters | GL45 | ST 45/40 | Borosilicate glass 3.3 | Labmax, Titrex, Minispensor |
Artikelliste
Order number | Model | Version | Filter | Synthetic coating | Material | Ideal for | Pore size | sterile | Packaging unit |
---|---|---|---|---|---|---|---|---|---|
5 377 300 | Check valve | Yes | Labmax, Titrex | ||||||
5 377 310 | Calcium chloride tube | Without calcium chloride | Yes | Labmax, Titrex | |||||
8 212 001 | One-way filter | Ø13 mm | PP (membrane made of regenerated cellulose) | Labmax, Titrex | 0.2 µm | 100 | |||
8 212 002 | One-way filter | Ø30 mm | PP (membrane made of regenerated cellulose) | Labmax, Titrex | 0.2 µm | 100 | |||
8 212 003 | One-way filter | Ø13 mm | PP (membrane made of regenerated cellulose) | Labmax, Titrex | 0.45 µm | 100 | |||
8 212 004 | One-way filter | Ø30 mm | PP (membrane made of regenerated cellulose) | Labmax, Titrex | 0.45 µm | 100 | |||
8 214 001 | One-way filter | Ø30 mm | PP (membrane made of regenerated cellulose) | Labmax, Titrex | 0.45 µm | Yes | 50 (individual sterile packed) | ||
8 214 002 | One-way filter | Ø30 mm | PP (membrane made of regenerated cellulose) | Labmax, Titrex | 0.2 µm | Yes | 50 (individual sterile packed) |
WITOPED eco is an economically priced electric pipette aid, suitable for all pipettes up to 100 ml. The new model has an advanced digital display and faster suction performance: 25 ml in less than 5 seconds.
Your advantage at a glance:
- suitable for all pipettes up to 100 ml and Pasteur pipettes
- most affordable price in its class
- digital display indicating battery status and selected speed
- fine adjustment of pipetting speed
- tight fit of any pipette into the pipette socket
- handy and light weighted for fatigue-free pipetting, only approximately 200 g
- simple but powerful motor for fast and reliable pipetting
- gravity drain mode (G) for draining out without using any motor
- nosepiece with replaceable filter and silicone adapter
- silicone adapter autoclavable at 121°C
- efficient battery for a long runtime, Li-Ion 3,7V 700 mAh
- battery life over 8 hours
- low battery alert, acoustic signal when the charge level is low
- rechargeable during use
- CE label
Artikelliste
Order number | Model | Version | Ideal for | Power supply | Packaging unit |
---|---|---|---|---|---|
5 381 000 | Witoped eco | Witoped eco | All pipettes up to 100 ml | 230 V | |
5 380 006 E | Replacement one-way filter Witoped eco | 0.45 µm hydrophobic | Witoped eco | 5 pieces | |
5 382 010 | Replacement silicone adapter Witoped eco | Replacement silicone adapter Witoped eco | Witoped eco |
Ideal for:
- multiple mixing and heating applications at the same time
- mixing of chemical, laboratory and pharmaceutical materials
- heat-sensitive procedures in microbiology and biochemistry
- sample drying and general lab heating applications
Features:
- each place individually adjustable
- digital Jog-Dial controller for each place
- up to 350°C
- up to 1.500 rpm
- ceramic-coated aluminium plate with 3 or 6 places 140x140 mm
- heat-, chemical- and restricted acid-resistant
- no liquid can get into the body
- powder-coated steel body
- easy to clean
- 30 mm stirrer bar included (3x / 6x)
- up to 3 temperature probes possible (3 & 6 place-type)
- CE certified and unique serial number for tracing
Safety mechanism:
- timer 99h 59min with timer-end signal
- error status
- locking mode
- operation LEDs
Controller:
- Jog-Dial controller with touch-button
Artikelliste
Order number | Model | Version | Width (Outer) | Length (outer) | Height (outer) | Connections | Controller | Housing material | Speed | Heating power | Capacity | Plate size | Plate material | Temperature control resolution | Temperature range with filter | Temperature accuracy | Packing size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WMH03503 | SMHS-3 230 V | 3 stirring points | 240 mm | 510 mm | 100 mm | 3 temperature sensor ports, 3 stand rod sockets | Digital | Powder-coated steel | 80 - 1500 rpm | 3 x 400 W | 20 l | 140 x 140 mm (each place) | Ceramic-coated aluminium | Display 0.1°C, control 0.5°C | 350°C | ±0.3°C | 540 x 330 x h170 mm |
DH.WMH03506 | SMHS-6 230 V | 6 (2x3) stirring points | 410 mm | 510 mm | 180 mm | 3 temperature sensor ports, 6 stand rod sockets | Digital | Powder-coated steel | 80 - 1500 rpm | 6 x 400 W | 20 l | 140 x 140 mm (each place) | Ceramic-coated aluminium | Display 0.1°C, control 0.5°C | 350°C | ±0.3°C | 570 x 540 x h230 mm |
Ideal for:
- enzyme reactions, inactivation of sera, incubation and other laboratory procedures
- multifunctional dry block heater
Features:
- new design: lighter and more compact then the previous model
- user‘s self-compensation function to offset between real temperature and indicated temperature (±10.0°C)
- ergonomic, compact design and modular block
- internal PPS bath ensures best insulation, block made of anodized aluminium
- precise temperature control
- digital timer function – delay time and operation control
- convenient integrated timer for time-sensitive incubations
- block removal tool with screw thread included
- storage function for the set values of temperature and timer
- various block types (optional)
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- locking mode
- overheat and over-current protection
- sensor error detection
Controller:
- digital fuzzy controller with Jog-Dial and main touch button
Artikelliste
Order number | Model | Version | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Heating time | Power consumption | Temperature range | Temperature accuracy | Packing size | Sensor |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WHB02000 | H-20 Einheit 230 V | 90 mm | 120 mm | 60 mm | 226 mm | 178 mm | 138 mm | approx. 5°C/min | 300 W | Room temperature +5°C to 150°C | ±0.1°C at 37°C, ±0.2°C to 90°C, ±0.4°C at 135°C | 230 x 290 x 245 mm | Temperature sensor PT100 | |
DH.WHB02100 | H-20 Set 230 V | incl. standard block with 48 holes for 1.5/2 ml centrifuge tubes | 90 mm | 120 mm | 60 mm | 226 mm | 178 mm | 138 mm | approx. 5°C/min | 300 W | Room temperature +5°C to 150°C | ±0.1°C at 37°C, ±0.2°C to 90°C, ±0.4°C at 135°C | 230 x 355 x 245 mm | Temperature sensor PT100 |
Ideal for:
- enzyme reactions, inactivation of sera, incubation and other laboratory procedures
- multifunctional dry block heater
Features:
- user‘s self-compensation function to offset between real temperature and indicated temperature (±10.0°C)
- unit made of stainless steel and powder-coated steel, block made of anodized aluminium
- digital timer function
- internal PPS bath ensures best insulation, block made of anodized aluminium
- precise temperature control
- block extraction tongs “BLE101” & block cover are included
- storage function for the set values of temperature and timer
- alarm function: error status and timer end
- various kinds of blocks are offered (optional)
- dual block and 2 molded heater (300W)
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- locking mode
- overheat and over-current protection
- sensor error detection
Controller:
- dual digital fuzzy controller with Jog-Shuttle-switch
Artikelliste
Order number | Model | Version | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Heating time | Power consumption | Temperature range | Temperature accuracy | Packing size | Sensor |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WHB00198 | HB-96D unit 230 V | 90 mm | 120 mm | 60 mm | 250 mm | 285 mm | 155 mm | approx. 5°C/min | 600 W | Room temperature +5°C to 150°C | ±0.1°C at 37°C, ±0.2°C to 90°C, ±0.4°C at 135°C | 400 x 270 x 200 mm | Temperature sensor PT100 | |
DH.WHB00199 | HB-96D set 230 V | incl. 2 standard blocks with 48 holes for 1.5/2 ml centrifuge tubes | 90 mm | 120 mm | 60 mm | 250 mm | 285 mm | 155 mm | approx. 5°C/min | 600 W | Room temperature +5°C to 150°C | ±0.1°C at 37°C, ±0.2°C to 90°C, ±0.4°C at 135°C | 400 x 270 x 200 mm | Temperature sensor PT100 |
Ideal for:
- enzyme reactions, inactivation of sera, incubation and other laboratory procedures
Features:
- user‘s self-compensation function to offset between real temperature and indicated temperature (±10.0°C)
- unit made of stainless steel and powder-coated steel, block made of anodized aluminium
- 2 peltier cooling modules
- unit made of stainless steel and powder-coated steel, block made of anodized aluminium
- block extraction tongs “BLE101” and block cover are included
- molded heater (300W), PT100 sensor
- storage function for the set values of temperature and timer
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- locking mode
- overheat and over-current protection
- sensor error detection
Controller:
- digital PID and fuzzy controller with Jog-Shuttle-switch
Artikelliste
Order number | Model | Version | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Cooling time | Heating time | Power consumption | Temperature range | Temperature accuracy | Packing size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WHB00248 | HB-R48 unit 230 V | 90 mm | 120 mm | 60 mm | 185 mm | 230 mm | 220 mm | 2.3°C/min. between 95°C to 25°C, 0.5°C/min. between 25°C to -5°C | approx. 5°C/min | 450 W | Room temperature -5°C to 95°C | ±0.1°C at 37°C, ±0.2°C to 90°C | 350 x 220 x 310 mm | |
DH.WHB00249 | HB-R48 set 230 V | incl. standard block with 48 holes for 1.5/2 ml centrifuge tubes | 90 mm | 120 mm | 60 mm | 185 mm | 230 mm | 220 mm | 2.3°C/min. between 95°C to 25°C, 0.5°C/min. between 25°C to -5°C | approx. 5°C/min | 450 W | Room temperature -5°C to 95°C | ±0.1°C at 37°C, ±0.2°C to 90°C | 350 x 220 x 310 mm |