The following products have been found matching your search "einheitlichen": 16
Ideal for:
- precise measurement with capillary viscometers
Features:
- powerful circulation pump ensures highest temperature uniformity
- stainless steel interior and lid with 5 holes for viscometer holder, powder-coated steel body, vacuum sealed and tempered safety glasses window
- storage function for the set values of temperature and timer
- digital timer function (99hr 59min): delay time and operation time can be controlled
- user‘s self-compensation function to control difference between real temperature and indicated temperature (±10.0°C)
- drain valve mounted
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- overheat and over-current protection sensor error detectionlocking mode
Controller:
- digital fuzzy controller with Jog-Shuttle-switch (turn + push)
Ideal for:
- biotechnology, clinical, environmental, medical, petroleum & food industry, pharmaceutical and industrial applications
- connection with evaporators and viscometers is applicable
Features:
- user‘s self-compensation function to control difference between real temperature and indicated temperature (±10.0°C)
- stainless steel bath & lid for superior durability & high thermal efficiency / consistency
- storage function for the set values of temperature and timer
- powerful circulation pump assures temperature uniformity: internal and external circulation
- storage function for the set values of temperature and timer
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- locking mode
- over- temperature and over-current protection
- sensor error detection
- low water level warning and automatic stop function
Controller:
- digital fuzzy controller with Jog-Shuttle-switch (turn + push)
Artikelliste
Order number | Model | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Drain valve | Connections | Capacity | Effective space | Pump performance | Power consumption | Temperature control resolution | Temperature range | Temperature fluctuation | Temperature accuracy | Packing size | Sensor | Flow rate |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WCB00106 | WCB-6 230 V | 300 mm | 155 mm | 150 mm | 330 mm | 185 mm | 385 mm | Circulation nozzle inner Ø7 x outer Ø11mm ( IØ 9 / OØ 12mm silicon tube connection for inner circulation) | 6 l | 120 x 155 x 150 mm | 5 l/min | 800 W | Display 0.1°C, control 0.1°C | Room temperature +5°C - 100°C | ±0.2°C | ±0.1°C | 350 x 210 x 340 mm | Temperature sensor PT100 | 5 l/Min (innen/außen) | |
DH.WCB00111 | WCB-11 230 V | 302 mm | 240 mm | 150 mm | 335 mm | 275 mm | 385 mm | Circulation nozzle inner Ø7 x outer Ø11mm ( IØ 9 / OØ 12mm silicon tube connection for inner circulation) | 11 l | 170 x 240 x 150 mm | 5 l/min | 1000 W | Display 0.1°C, control 0.1°C | Room temperature +5°C - 100°C | ±0.2°C | ±0.1°C | 360 x 300 x 420 mm | Temperature sensor PT100 | 5 l/Min (innen/außen) | |
DH.WCB00122 | WCB-22 230 V | 500 mm | 295 mm | 150 mm | 540 mm | 335 mm | 410 mm | mounted (Ø9.5 - 11mm) | Circulation nozzle inner Ø7 x outer Ø11mm ( IØ 9 / OØ 12mm silicon tube connection for inner circulation) | 22 l | 372 x 295 x 150 mm | 5 l/min | 2000 W | Display 0.1°C, control 0.1°C | Room temperature +5°C - 100°C | ±0.2°C | ±0.1°C | 580 x 380 x 470 mm | Temperature sensor PT100 | 5 l/Min (innen/außen) |
Ideal for:
- multi-use digital precise immersion circulator head
Features:
- user‘s self-compensation function to control difference between real temperature and indicated temperature (±10.0°C)
- digital timer function (99hr 59min): delay time and operation time can be controlled
- powerful circulation pump assures temperature uniformity
- storage function for the set values of temperature and timer
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- locking mode
- over- temperature and over-current protection
- sensor error detection
- low water level warning and automatic stop function
Controller:
- digital fuzzy controller with Jog-Shuttle-switch (turn + push)
Artikelliste
Order number | Model | Width (Outer) | Length (outer) | Height (outer) | Capacity | Pump performance | Power consumption | Temperature range | Temperature accuracy | Packing size | Sensor |
---|---|---|---|---|---|---|---|---|---|---|---|
DH.WCB10011 | WCB-11H 230 V | 130 mm | 165 mm | 320 mm | 11 l | 5 l/min | 1000 W | Room temperature +5°C - 100°C | ±0.1°C | 400 x 280 x 200 mm | Temperature sensor PT100 |
DH.WCB10022 | WCB-22H 230 V | 130 mm | 165 mm | 320 mm | 22 l | 5 l/Min | 2000 W | Raumtemperatur +5°C - 100°C | ±0,1°C | 400 x 280 x 200 mm | Temperatursensor PT100 |
Ideal for:
- connection with evaporator
Features:
- stainless steel bath, polyurethane insulation of 40 mm thickness and body made of powder-coated steel
- innovated refrigeration system ensures temperature performance, includes intelligent control for preventing compressor overload, CFC-free (R-404A)
- innovated powerful circulation pump ensures temperature uniformity: internal and external circulation and 5 steps circulation speed
- stainless steel flat lid & valve ball included, dome lid optional
- RS232C interface: remote monitoring and controlling with PC
- proper liquid level tag in bath
- user‘s self-compensation function to control difference between real temperature and indicated temperature (±10.0°C)
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- overheat and over-current protection
- sensor error detection and leakage breaker
- low liquid level warning and automatic stop function
- locking mode
Controller:
- digital fuzzy controller with Jog-Dial-switch (turn + push) & capacitive touch button
Artikelliste
Order number | Model | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Ideal for | Connections | Pressure | Heating power | Capacity | Effective space | Pump performance | Temperature variation | Temperature control resolution | Temperature range | Temperature accuracy | Packing size | Refrigerator | Cooling capacity | Sensor | Flow rate |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WCR00408 | WCR-8 230 V | 175 mm | 320 mm | 150 mm | 330 mm | 474 mm | 752 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 1000 W | 8 l | 175 x 153 x 150 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -10°C | Display 0.1°C, control 0.1°C | -25°C - +150°C | ±0.1°C | 560 x 420 x 922 mm | 250 W | 300 W at +20°C, 200 W at 0°C, 110 W at -20°C | Temperature sensor PT100 | 25l/Min. |
DH.WCR00412 | WCR-12 230 V | 230 mm | 350 mm | 150 mm | 400 mm | 523 mm | 807 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 1500 W | 12 l | 230 x 181 x 150 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -10°C | Display 0.1°C, control 0.1°C | -25°C - +150°C | ±0.1°C | 630 x 530 x 972 mm | 250 W | 380 W at +20°C, 250 W at 0°C, 130 W at -20°C | Temperature sensor PT100 | 25l/Min. |
DH.WCR00422 | WCR-22 230 V | 290 mm | 390 mm | 200 mm | 483 mm | 563 mm | 850 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 2000 W | 22 l | 290 x 220 x 200 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -10°C | Display 0.1°C, control 0.1°C | -25°C - +150°C | ±0.1°C | 670 x 615 x 1022 mm | 370 W | 680 W at +20°C, 500 W at 0°C, 300 W at -20°C | Temperature sensor PT100 | 25l/Min. |
DH.WCR00430 | WCR-30 230 V | 330 mm | 460 mm | 200 mm | 494 mm | 633 mm | 906 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 2200 W | 30 l | 330 x 290 x 200 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -10°C | Display 0.1°C, control 0.1°C | -25°C - +150°C | ±0.1°C | 740 x 625 x 1072 mm | 560 W | 850 W at +20°C, 620 W at 0°C, 400 W at -20°C | Temperature sensor PT100 | 25l/Min. |
Ideal for:
- connection with evaporator
Features:
- stainless steel bath, polyurethane insulation of 40 mm thickness and body made of powder-coated steel
- innovated refrigeration system ensures temperature performance, includes intelligent control for preventing compressor overload, CFC-free (R-404A)
- innovated powerful circulation pump ensures temperature uniformity: internal and external circulation and 5 steps circulation speed
- stainless steel flat lid & valve ball included, dome lid optional
- RS232C interface: remote monitoring and controlling with PC
- proper liquid level tag in bath
- user‘s self-compensation function to control difference between real temperature and indicated temperature (±10.0°C)
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- overheat and over-current protection
- sensor error detection and leakage breaker
- low liquid level warning and automatic stop function
- locking mode
Controller:
- digital fuzzy controller with Jog-Dial-switch (turn + push) & capacitive touch button
Artikelliste
Order number | Model | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Ideal for | Connections | Pressure | Heating power | Capacity | Effective space | Pump performance | Temperature variation | Temperature control resolution | Temperature range | Temperature accuracy | Packing size | Refrigerator | Cooling capacity | Sensor | Flow rate |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WCL00408 | WCL-8 230 V | 175 mm | 320 mm | 150 mm | 400 mm | 523 mm | 807 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 1000 W | 8 l | 175 x 153 x 150 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -20°C | Display 0.1°C, control 0.1°C | -35°C - +150°C | ±0.1°C | 630 x 530 x 972 mm | 370 W | 500 W at +20°C, 340 W at 0°C, 200 W at -20°C | Temperature sensor PT100 | 25l/Min. |
DH.WCL00412 | WCL-12 230 V | 230 mm | 350 mm | 150 mm | 400 mm | 523 mm | 807 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 1500 W | 12 l | 230 x 181 x 150 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -20°C | Display 0.1°C, control 0.1°C | -35°C - +150°C | ±0.1°C | 630 x 530 x 972 mm | 370 W | 530 W at +20°C, 370 W at 0°C, 210 W at -20°C | Temperature sensor PT100 | 25l/Min. |
DH.WCL00422 | WCL-22 230 V | 290 mm | 390 mm | 200 mm | 483 mm | 563 mm | 850 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 2000 W | 22 l | 290 x 220 x 200 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -20°C | Display 0.1°C, control 0.1°C | -35°C - +150°C | ±0.1°C | 670 x 615 x 1022 mm | 650 W | 860 W at +20°C, 620 W at 0°C, 400 W at -20°C | Temperature sensor PT100 | 25l/Min. |
DH.WCL00430 | WCL-30 230 V | 330 mm | 460 mm | 200 mm | 494 mm | 633 mm | 906 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 2200 W | 30 l | 330 x 290 x 200 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -20°C | Display 0.1°C, control 0.1°C | -35°C - +150°C | ±0.1°C | 740 x 625 x 1072 mm | 750 W | 1030 W at +20°C, 760 W at 0°C, 500 W at -20°C | Temperature sensor PT100 | 25l/Min. |
Ideal for:
- protection of samples and work processes against dust and particulate contamination
Features:
- class 100 HEPA filter of efficiency up to 99.97% & 0.3 micron size (easy to exchange)
- mesh guard for HEPA filter protection
- vertical air flow-type
- optimized air flow system for uniform air flow/velocity
- 8 steps air velocity control
- UV and fluorescent lamp, external gas connection valve, internal electrical outlet
- silent and vibration-free blower (under 65 dB)
- corrosion resistant 304 stainless steel working table interior, powder-coated body and tempered safety glass sliding door for protection from UV radiation
- 99hr 59min timer
- high-quality backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- UV protection system: UV lamp is only activated when safety glass door is completely closed
Controller:
- microprocessor digital controller
- high performance touch input
Artikelliste
Order number | Model | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Filter | Ideal for | Connections | Illumination | Speed | Air volume |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WLCV1200 | WLC-V1200 230 V | 1200 mm | 660 mm | 610 mm | 1280 mm | 735 mm | 1895 mm | HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal | Protection of samples and work processes against dust and particulate contamination | 1 x air cock, 1 x gas cock, 2 x 230 V outlet | 1 x UV 20 W, 1 x FL 36 W | Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps | 1350 m2/h |
DH.WLCV1500 | WLC-V1500 230 V | 1500 mm | 660 mm | 610 mm | 1580 mm | 735 mm | 1895 mm | HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal | Protection of samples and work processes against dust and particulate contamination | 1 x air cock, 1 x gas cock, 2 x 230 V outlet | 1 UV 30 W, 1 x FL 55 W | Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps | 1700 m2/h |
DH.WLCV1800 | WLC-V1800 230 V | 1800 mm | 660 mm | 610 mm | 1880 mm | 735 mm | 1895 mm | HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal | Protection of samples and work processes against dust and particulate contamination | 1 x air cock, 1 x gas cock, 2 x 230 V outlet | 1 UV 30 W, 1 x FL 55 W | Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps | 2020 m2/h |
Laboratory 1000 ml, ST 29/32, one stopper size, Ø 101 mm, height 230 mm, autoclavable, heat resistant, with graduation, laboratory bottle inclusve with hollow-hexagonal glass stopper, BORO. 3.3, amber stained, pack = 10 pieces
Laboratory bottle 2000 ml, ST 29/32, one stopper size, Ø 136 mm, height 265 mm, autoclavable, heat resistant, with graduation, laboratory bottle inclusive with hollow-hexagonal glass stopper, BORO.3.3, amber stained, pack = 10 pieces
Laboratory bottle 100 ml, ST 29/32, one stopper size, Ø 56 mm, height 105 mm, autoclavable, heat resistant, with graduation, laboratory bottle inclusive hollow-hexagonal glass stopper, BORO. 3.3, amber stained, pack = 10 pcs
Laboratory bottle 250 ml, ST 29/32, one stopper size, Ø 70 mm, height 143 mm, autoclavable, heat resistant, with graduation, laboratory bottle inclusive with hollow-hexagonal glass stopper, BORO. 3.3, amber stained, pack = 10 pieces
Laboratory bottle 500 ml, ST 29/32, one stopper size, Ø 86 mm, height 181 mm, autoclavable, heat resistant, with graduation, laboratory bottle inclusive with hollow-hexagonal glass stopper, BORO. 3.3, amber stained, pack = 10 pieces
Ideal for:
- enzyme reactions, inactivation of sera, incubation and other laboratory procedures
- multifunctional dry block heater
Features:
- user‘s self-compensation function to offset between real temperature and indicated temperature (±10.0°C)
- unit made of stainless steel and powder-coated steel, block made of anodized aluminium
- digital timer function
- internal PPS bath ensures best insulation, block made of anodized aluminium
- precise temperature control
- block extraction tongs “BLE101” & block cover are included
- storage function for the set values of temperature and timer
- alarm function: error status and timer end
- various kinds of blocks are offered (optional)
- dual block and 2 molded heater (300W)
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- locking mode
- overheat and over-current protection
- sensor error detection
Controller:
- dual digital fuzzy controller with Jog-Shuttle-switch
Artikelliste
Order number | Model | Version | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Heating time | Power consumption | Temperature range | Temperature accuracy | Packing size | Sensor |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WHB00198 | HB-96D unit 230 V | 90 mm | 120 mm | 60 mm | 250 mm | 285 mm | 155 mm | approx. 5°C/min | 600 W | Room temperature +5°C to 150°C | ±0.1°C at 37°C, ±0.2°C to 90°C, ±0.4°C at 135°C | 400 x 270 x 200 mm | Temperature sensor PT100 | |
DH.WHB00199 | HB-96D set 230 V | incl. 2 standard blocks with 48 holes for 1.5/2 ml centrifuge tubes | 90 mm | 120 mm | 60 mm | 250 mm | 285 mm | 155 mm | approx. 5°C/min | 600 W | Room temperature +5°C to 150°C | ±0.1°C at 37°C, ±0.2°C to 90°C, ±0.4°C at 135°C | 400 x 270 x 200 mm | Temperature sensor PT100 |
Ideal for:
- enzyme reactions, inactivation of sera, incubation and other laboratory procedures
Features:
- user‘s self-compensation function to offset between real temperature and indicated temperature (±10.0°C)
- unit made of stainless steel and powder-coated steel, block made of anodized aluminium
- 2 peltier cooling modules
- unit made of stainless steel and powder-coated steel, block made of anodized aluminium
- block extraction tongs “BLE101” and block cover are included
- molded heater (300W), PT100 sensor
- storage function for the set values of temperature and timer
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- locking mode
- overheat and over-current protection
- sensor error detection
Controller:
- digital PID and fuzzy controller with Jog-Shuttle-switch
Artikelliste
Order number | Model | Version | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Cooling time | Heating time | Power consumption | Temperature range | Temperature accuracy | Packing size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WHB00248 | HB-R48 unit 230 V | 90 mm | 120 mm | 60 mm | 185 mm | 230 mm | 220 mm | 2.3°C/min. between 95°C to 25°C, 0.5°C/min. between 25°C to -5°C | approx. 5°C/min | 450 W | Room temperature -5°C to 95°C | ±0.1°C at 37°C, ±0.2°C to 90°C | 350 x 220 x 310 mm | |
DH.WHB00249 | HB-R48 set 230 V | incl. standard block with 48 holes for 1.5/2 ml centrifuge tubes | 90 mm | 120 mm | 60 mm | 185 mm | 230 mm | 220 mm | 2.3°C/min. between 95°C to 25°C, 0.5°C/min. between 25°C to -5°C | approx. 5°C/min | 450 W | Room temperature -5°C to 95°C | ±0.1°C at 37°C, ±0.2°C to 90°C | 350 x 220 x 310 mm |