Close filters
  •  
    •  
    •  
from to
1 From 2
No results were found for the filter!
Tangential flow filtration (TFF) system Tanfil 100 -
Tangential flow filtration (TFF) system Tanfil 100

Ideal for:

  • concentration and desalting
  • diafiltration and purification
  • buffer exchange and dialysis

 

Features:

  • enables concentration and diafiltration in one
  • inlet parallel to the membrane
  • Plug & Start device
  • CE certification


Safety mechanism:

  • with motor overload protection
  • with fuse
Vacuum filtration system WaterVac 100 -540mmg with integrated vacuum pump
Vacuum filtration system WaterVac 100 -540mmg with integrated vacuum pump

Ideal for:

  • microbiological filtration technique for analyzing aqueous-based fluids for microbiological contamination
  • suspended solid test for municipal, surface, ground and drinking water
  • general filtration without the need of collecting filtrate

Features:

  • -540 mmHg
  • up to 0,5 l/min (liquid) or 2,2 l/min (air)
  • integrated vacuum pump
  • compact design - ideal for work benches or laminar flow hoods
  • no special suction flask or waste bottle is needed
  • available with spin-lock or stopper design
  • one push-button for easy operation
  • silicone tube (2m) for waste drain included

Artikelliste

Order number Model Version Width (Outer) Length (outer) Height (outer) Diameter (outer) Material Ideal for Connections Vacuum range
00829 190110-02 MultiVac 100 spin-lock with spin-lock 120 mm 170 mm 96 mm Filter: Ø47 mm / 50 mm Housing: SUS 304; valve plate: EPDM; diaphragm: EPDM; inlet / outlet port: SUS 316; O-ring: FKM; tube: silicone Microbiological filtration technique for analysing aqueous-based fluids for microbiological contamination, suspended solid test for municipal, surface, ground and drinking water, general filtration without the need of collection filtrate EU-plug max. -540 mmHg
00829 190120-02 120 mm Filter: ?47 mm / 50 mm EU-Anschluss Max. -540 mmHg
Vacuum filtration system Lafil 400 22/25L/min -720mmHg with integrated vacuum pump
Vacuum filtration system Lafil 400 22/25L/min -720mmHg with integrated vacuum pump

Ideal for:

  • filtration for microbiology tests
  • suspended solid tests
  • general laboratory filtration
  • vacuum filtration
  • cell culture aspiration
  • laboratory waste suction

 

Features:

  • -720 mmHg
  • up to 25 l/min
  • combines vacuum source with filtration accessories
  • compact design
  • different sets available
  • CE certified

 

Artikelliste

Order number Model Width (Outer) Length (outer) Height (outer) Diameter (outer) Filter Material Ideal for Power supply Connections Speed Capacity Vacuum range Accessories Flow rate
00829 197400-22 Lafil 400 230V 23 mm 33.5 mm 45 cm Filtration for microbiology tests, suspended solid tests, general laboratory filtration, vacuum filtration, cell culture aspiration, laboratory waste suction Current 0.4 A 5/16 inch (8 mm) Motor ration: 1450 rpm max. 33 mbar 25 l/Min
00829 197401-22 Lafil 400 230V with LF 30 23 mm 33.5 mm 45 cm Filter: Ø47 mm Filter: 25 mm, 0.2 μm Filter funnel: PES; waste bottle: PC; funnel support base: PP; funnel lid: PP (containing PTFE syringe filter); overflow protection: PP Filtration for microbiology tests, suspended solid tests, general laboratory filtration, vacuum filtration, cell culture aspiration, laboratory waste suction Current 0.4 A 5/16 inch (8 mm) Motor ration: 1450 rpm Funnel: 300 ml, waste bottle: 1200 ml max. -720 mmHg 22 l/Min
00829 197402-22 Lafil 400 230V with SF10 23 mm 33.5 mm 45 cm Filter: Ø47 mm Filter funnel: stainless steel SUS316; waste bottle: PC; funnel support base: stainless steel SUS316; overflow protection: PP Filtration for microbiology tests, suspended solid tests, general laboratory filtration, vacuum filtration, cell culture aspiration, laboratory waste suction Current 0.4 A 5/16 inch (8 mm) Motor ration: 1450 rpm Funnel: 100 ml, waste bottle: 1200 ml max. -720 mmHg 22 l/Min
00829 197404-22 Lafil 400 230V with LF 5a 23 mm 33.5 mm 45 cm Filter: Ø47 mm Filter funnel: PES; tissue bottle: borosilicate glass; funnel support base: PP Filtration for microbiology tests, suspended solid tests, general laboratory filtration, vacuum filtration, cell culture aspiration, laboratory waste suction Current 0.4 A 5/16 inch (8 mm) Motor ration: 1450 rpm Funnel: 500 ml, bottle: 500 ml max. -720 mmHg 22 l/Min
00829 197405-22 Lafil 400 plus 230V Suction bottle: PC; 1-channel tip adaptor with ejector: POM; 8-channel tip adaptor with ejector: POM; 1-channel tip adaptor (150 mm): POM Filtration for microbiology tests, suspended solid tests, general laboratory filtration, vacuum filtration, cell culture aspiration, laboratory waste suction Suction bottle: 1200 ml max. -540 mmHg Handle, 1-channel tip adaptor and 8-channel tip adaptor
VITON-O-Ring for Biogen-cross-flow-micro-filtration-modules - 2 340 005
VITON-O-Ring for Biogen-cross-flow-micro-filtration-modules
VITON-O-RING, FOR BIOGEN-CROSS- FLOW-MICRO-FILTRATION-MODULES
Immersion filters for reverse filtration P0 - 2 376 030
Immersion filters for reverse filtration P0
Immersion filters for reverse filtration, P0, disc diam. 35 mm
Immersion filters for reverse filtration P1 - 2 376 031
Immersion filters for reverse filtration P1
Immersion filters for reverse filtration, P1, disc diam. 35 mm
Immersion filters for reverse filtration P2 - 2 376 032
Immersion filters for reverse filtration P2
Immersion filters for reverse filtration, P2, disc diam. 35 mm
IMMERSION FILTERS FOR REVERSE FILTRATION P3 - 2 376 033
IMMERSION FILTERS FOR REVERSE FILTRATION P3
IMMERSION FILTERS FOR REVERSE FILTRATION, P3, DISC DIAM. 35 MM
Immersion filters for reverse filtration P4 - 2 376 034
Immersion filters for reverse filtration P4
Immersion filters for reverse filtration, P4, disc diam. 35 mm
Micro immersion filters f. reverse filtration P0 - 2 380 060
Micro immersion filters f. reverse filtration P0
Micro immersion filters f. reverse filtration, P0, disc diam. 10 mm
Micro immersion filters f. reverse filtration P1 - 2 380 061
Micro immersion filters f. reverse filtration P1
Micro immersion filters f. reverse filtration, P1, disc diam. 10 mm
MICRO IMMERSION FILTERS F. REVERSE FILTRATION P 2 - 2 380 062
MICRO IMMERSION FILTERS F. REVERSE FILTRATION P 2
MICRO IMMERSION FILTERS F. REVERSE FILTRATION, P 2, DISC DIAM. 10 MM
Micro immersion filters f. reverse filtration P 3 - 2 380 063
Micro immersion filters f. reverse filtration P 3
Micro immersion filters, f. reverse filtration, P 3, disc diam. 10 mm
Micro immersion filters f. reverse filtration P 4 - 2 380 064
Micro immersion filters f. reverse filtration P 4
Micro immersion filters f. reverse filtration, P 4, disc diam. 10 mm
Filter holder VF3 / VF5 / VF6 / VF7 / VF8 / VF16 made of glass Ø25mm / Ø47mm / Ø90mm
Filter holder VF3 / VF5 / VF6 / VF7 / VF8 / VF16 made of glass Ø25mm / Ø47mm / Ø90mm

VF5 & VF8 Ø25mm
Ideal for:

  • small volume vacuum filtration for biological or particulate contamination analysis

 

VF6 & VF7 Ø47mm
Ideal for:

  • solvent purification and general filtration for microbiology, suspended solid analysis etc.

 

VF3 & VF16 Ø47mm / Ø90mm
Ideal for:

  • purification of organic, corrosive liquid such as solvent, mobile phase for HPLC, GC and AA analysis

 

Artikelliste

Order number Model Version Diameter (outer) Material Ideal for Capacity Stopper
00829 167200-05 VF5 filtration set, complete with receiver flask Filter: Ø25 mm Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass Small volume vacuum filtration for biological or particulate contamination analysts Funnel: 15 ml, receiver flask: 125 ml No. 5
00829 167120-32 VF5 filtration set, filter holder without receiver flask Filter: Ø25 mm Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone Small volume vacuum filtration for biological or particulate contamination analysts Funnel: 15 ml No. 5
00829 167200-08 VF8 filtration set, complete with receiver flask Filter: Ø25 mm Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass Small volume vacuum filtration for biological or particulate contamination analysts Funnel: 15 ml, receiver flask: 125 ml No. 5
00829 167120-34 VF8 filtration set, filter holder without receiver flask Filter: Ø25 mm Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone Small volume vacuum filtration for biological or particulate contamination analysts Funnel: 15 ml No. 5
00829 167200-06 VF6 filtration set, complete with receiver flask Filter: Ø47 mm Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass; fixing sucker: silicone Solvent purification and general filtration for microbiology, suspended solid analysis etc. Funnel: 300 ml, receiver flask: 1000 ml No. 8
00829 167120-31 VF6 filtration set, filter holder without receiver flask and fixing sucker Filter: Ø47 mm Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone Solvent purification and general filtration for microbiology, suspended solid analysis etc. Funnel: 300 ml No. 8
00829 167200-07 VF7 filtration set, complete with receiver flask and fixing sucker Filter: Ø47 mm Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass; fixing sucker: silicone Solvent purification and general filtration for microbiology, suspended solid analysis etc. Funnel: 300 ml, receiver flask: 1000 ml No. 8
00829 167120-33 VF7 filtration set , filter holder without receiver flask and fixing sucker Filter: Ø47 mm Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone Solvent purification and general filtration for microbiology, suspended solid analysis etc. Funnel: 300 ml No. 8
00829 167200-03 VF3 filtration set, complete with receiver flask and fixing sucker Filter: Ø47 mm Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, suction cap: borosilicate glass; receiver flask: borosilicate glass; fixing sucker: silicone Purification of organic, corrosive liquid such as solvent (mobile phase) for HPLC analysis Funnel: 300 ml, receiver flask: 1000 ml
00829 167120-30 VF3 filtration set, filter holder without receiver flask and fixing sucker Filter: Ø47 mm Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, suction cap: borosilicate glass Purification of organic, corrosive liquid such as solvent (mobile phase) for HPLC analysis Funnel: 300 ml
00829 167200-16 VF16 filtration set, complete with receiver flask Filter: Ø90 mm Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: PTFE coated; gasket: PTFE; suction cap: borosilicate glass; receiver flask: borosilicate glass Purification of organic, corrosive liquid such as solvent, mobile phase for HPLC, GC and AA analysis Funnel: 1000 ml, receiver flask: 5000 ml
Filter holder LF30 / LF31 / LF3 / LF5 /LF3a / LF5a / MF3 / MF3a / MF5 / MF5a made of PES Ø47mm
Filter holder LF30 / LF31 / LF3 / LF5 /LF3a / LF5a / MF3 / MF3a / MF5 / MF5a made of PES Ø47mm

LF30 & LF31 Ø47mm
Features:

  • spin-lock connection facilitates fast and stable installation without clamp
  • excellent smash and high temperature resistance
  • autoclavable
  • built-in overflow protection to keep the filtrate from overflowing when waste bottle is full
  • funnel graduated in 50ml, receiver in 100ml increments for easy measurement

 

LF 3 / 5 & LF 3a / 5a Ø47mm
Features:

  • spin-lock connection facilitates fast and stable installation without clamp
  • PES structure offers excellent smash and high temperature resistance (up to 180°C)
  • autoclavable
  • reusable
  • funnel graduated in 50ml increments for easy measurement

 

MF 3 / 5 & MF 3a / 5a Ø47mm
Features:

  • magnetic connection facilitates fast and stable installation without clamp
  • strong magnetic seal allows one-handed operation, prevents possible twisting and tearing of the membrane
  • membrane guide on the base helps positioning membrane easily
  • PES structure offers excellent smash and high temperature resistance (up to 180°C)
  • funnel graduated in 50ml increments for easy measurement
  • autoclavable
  • reusable

 

Artikelliste

Order number Model Version Diameter (outer) Filter Thread Material Ideal for Connections Capacity Stopper
00829 197000-01 LF 30 PES filtration set, filter holder without PC waste bottle with cover Filter: Ø47 mm 25 mm, 0.2 μm Filter holder: PES; filter: PTFE; lid kit: PP, funnel: PES; support screen: PP; support base: PC; stopper: silicone Spin-lock connection Funnel: 300 ml No. 16
00829 197000-03 LF 5 PES filter holder, complete without lid kit Filter: Ø47 mm 25 mm, 0.2 μm Filter: PTFE; funnel: PES; support screen: PP; support base: PC; stopper: silicone Spin-lock connection Funnel: 500 ml No. 16
00829 197000-02 LF 3a PES filter holder, complete with lid kit Filter: Ø47 mm 25 mm, 0.2 μm Bottle adapter: GL45 Filter: PTFE; lid kit: PP, silicone; funnel: PES; support screen: PP Spin-lock connection Funnel: 300 ml
00829 197000-04 LF 5a PES filter holder, complete without lid kit Filter: Ø47 mm 25 mm, 0.2 μm Bottle adapter: GL45 Filter: PTFE; funnel: PES; support screen: PP Spin-lock connection Funnel: 500 ml
00829 200300-01 MF3 Filter holder with long stem Filter: Ø47 mm Lid kit: PP, funnel: PES; support base: PES, stopper: silicone Can be used for WaterVac100 with stopper design Funnel: 300 ml No. 8
00829 200500-01 MF5 Filter holder with long stem Filter: Ø47 mm Lid kit: PP, funnel: PES; support base: PES, stopper: silicone Can be used for WaterVac100 with stopper design Funnel: 500 ml No. 8
00829 200310-01 MF 3a Filter holder with short stem Filter: Ø47 mm Lid kit: PP, funnel: PES; support base: PP Funnel: 300 ml
00829 200510-01 MF 5a Filter holder with short stem Filter: Ø47 mm Lid kit: PP, funnel: PES; support base: PP Funnel: 500 ml
00829 197010-30 LF 30 PES filtration set, complete with PC waste bottle with cover Filter: Ø47 mm 25 mm, 0.2 μm Filter holder: PES; filter: PTFE; lid kit: PP, funnel: PES; support screen: PP; support base: PC; stopper: silicone; cap: PP; cover: PC; waste bottle: PC Spin-lock connection Funnel: 300 ml, receiver flask: 1200 ml No. 16
00829 197010-31 LF 31 PES filtration set, complete with receiver flask and fixing sucker Filter: Ø47 mm 25 mm, 0.2 μm Filter holder: PES; filter: PTFE; lid kit: PP, funnel: PES; support screen: PP; support base: PC; stopper: silicone;receiver flask: borosilicate glass; fixing sucker: silicone Spin-lock connection Funnel: 300 ml, receiver flask: 1000 ml No. 16
Filter holder SF10 / SF30 / filter holder made from stainless steel Ø47mm
Filter holder SF10 / SF30 / filter holder made from stainless steel Ø47mm

SF10 & SF30 Ø47mm
Ideal for:

  • spin-lock connection facilitates fast and stable installation without clamp
  • stainless steel funnel offers excellent chemical resistance and can be sterilized
  • built-in overflow protection to keep the filtrate from overflowing when waste bottle is full

 

Artikelliste

Order number Model Version Diameter (outer) Material Ideal for Connections Capacity Stopper
00829 197010-32 SF10 filtration set, complete with PC waste bottle with cover Filter: Ø47 mm Filter: stainless steel; funnel: stainless steel; support screen: stainless steel; support base: stainless steel; stopper: silicone; cap: PP; cover PC; waste bottle: PC SF-Spin-lock connection Funnel: 100 ml, receiver flask: 1200 ml No. 16
00829 197010-33 SF30 filtration set, complete with PC waste bottle with cover Filter: Ø47 mm Filter: stainless steel; funnel: stainless steel; support screen: stainless steel; support base: stainless steel; stopper: silicone; cap: PP; cover PC; waste bottle: PC SF-Spin-lock connection Funnel: 300 ml, receiver flask: 1200 ml No. 16
00829 180100-11 Stainless steel lids 100ml filter holder
00829 180100-13 Stainless steel lids 300 ml and 500 ml filter holder
Manifold MultiVac X10-MS, with 3 or 6 places, aluminium with stopper connections
Manifold MultiVac X10-MS, with 3 or 6 places, aluminium with stopper connections

Ideal for:

  • filtration for microbiology tests
  • chemistry experiments
  • general laboratory filtration

 

Features:

  • MultiVac 310-MS is made of anodized aluminium
  • includes 3x silicone stopper No. 8 to fit various types of filter holder
  • each branch permits individual control
  • quick-fit hose barb can be connected to both sides

 

Artikelliste

Order number Model Version Width (Outer) Length (outer) Height (outer) Material Ideal for Connections Stopper
00829 180610-01 MultiVac 610-MS 6 branches 85 cm 13 cm 16 cm Body, control valve, handle, hose barb: anodized aluminium; stopper: silicone Filtration for microbiology tests, chemistry experiments, general laboratory filtration 5/16 inch (8 mm) No. 8
00829 180310-01 MultiVac 310-MS 3 branches 48 cm 13 cm 16 cm Body, control valve, handle, hose barb: anodized aluminium; stopper: silicone Filtration for microbiology tests, chemistry experiments, general laboratory filtration 5/16 inch (8 mm) No. 8
Manifold MultiVac 300-MS/600-MS 3/6 places stainless steel with stopper connections
Manifold MultiVac 300-MS/600-MS 3/6 places stainless steel with stopper connections

Ideal for:

  • filtration for microbiology tests
  • chemistry experiments
  • general laboratory filtration

 

Features:

  • MultiVac MS is made of anodized aluminium and stainless steel
  • includes silicone stopper No. 8 to fit various types of filter holder
  • each branch permits individual control
  • adjustable vent valve design helps to drain residual liquid off the tube
  • innovative vent valve design prevents from water hammer phenomenon
  • quick-fit hose barb can be connected to both sides

 

Artikelliste

Order number Model Version Width (Outer) Length (outer) Height (outer) Diameter (outer) Material Ideal for Connections Capacity Stopper
00829 180300-01 MultiVac 300-MS 3 branches 48 cm 13 cm 11 cm Filter: Ø47 mm / 50 mm Body, control valve, filter funnel, funnel support base: stainless steel SUS316; control valve, handle: anodized aluminium; stopper: silicone Filtration for microbiology tests, chemistry experiments, general laboratory filtration 5/16 inch (8 mm) possible funnel capacity: 100ml / 300 ml / 500 ml No. 8
00829 180600-01 MultiVac 600-MS 6 branches 85 cm 13 cm 11 cm Filter: Ø47 mm / 50 mm Body, control valve, filter funnel, funnel support base: stainless steel SUS316; control valve, handle: anodized aluminium; stopper: silicone Filtration for microbiology tests, chemistry experiments, general laboratory filtration 5/16 inch (8 mm) possible funnel capacity: 100ml / 300 ml / 500 ml No. 8
Manifold MultiVac 300-MB/600-MB 3/6 places stainless steel with spin-lock for stainless steel funnels
Manifold MultiVac 300-MB/600-MB 3/6 places stainless steel with spin-lock for stainless steel funnels

Ideal for:

  • filtration for microbiology tests
  • chemistry experiments
  • general laboratory filtration

 

Features:

  • MultiVac MB is made of anodized aluminium and stainless steel
  • compatible with different sizes of funnels
  • each branch permits individual control
  • adjustable vent valve design helps to drain residual liquid off the tube
  • innovative vent valve design prevents from water hammer phenomenon
  • quick-fit hose barb can be connected to both sides

 

Artikelliste

Order number Model Version Width (Outer) Length (outer) Height (outer) Diameter (outer) Material Ideal for Connections Capacity Stopper
00829 180300-02 MultiVac 300-MB 3 branches 48 cm 13 cm 11 cm Filter: Ø47 mm / 50 mm Body, control valve, filter funnel, funnel support base: stainless steel SS316; control valve, handle: anodized aluminium; stopper: silicone Filtration for microbiology tests, chemistry experiments, general laboratory filtration 5/16 inch (8 mm), Spin-lock connection possible funnel capacity: 100ml / 300 ml / 500 ml No. 8
00829 180600-02 MultiVac 600-MB 6 branches 85 cm 13 cm 11 cm Filter: Ø47 mm / 50 mm Body, control valve, filter funnel, funnel support base: stainless steel SS316; control valve, handle: anodized aluminium; stopper: silicone Filtration for microbiology tests, chemistry experiments, general laboratory filtration 5/16 inch (8 mm), Spin-lock connection SF type possible funnel capacity: 100ml / 300 ml / 500 ml No. 8
Manifold Sets with vacuum pumps and waste bottles
MultiVac 310-MS-T

MultiVac 310-MS-T
Ideal for

  • filtration for suspended solid test
  • filtration for microbiology test
  • general laboratory filtration

 

MultiVac 301-MB-T
Ideal for

  • filtration for microbiology test
  • chemical experiments
  • general laboratory filtration

 

MultiVac 601-MB-T
Ideal for

  • filtration for microbiology test
  • chemical experiments
  • general laboratory filtration

 

Artikelliste

Order number Model Version Material Ideal for Connections Capacity Pump performance
00829 180311-22-T MultiVac 310-MS-T 230 V Oil free vacuum pump Rocker 400 230 V, anodized aluminium maifold MultiVac 310-MS, 3 places with stopper, 3 x magnetic PES filter holder 300 ml, waste bottle PP 4000 ml, silicone tube (2m) Waste bottle: PP, tube: silicone, filter holder: PES, manifold: anodized aluminium Filtration for suspended solid test, filtration for microbiology test, general laboratory filtration Funnel with magnetic connections Filter holder: 300 ml; waste bottle: 4000 ml 37 l/min, -670 mmHg
00829 180300-22-T MultiVac 301-MB-T 230 V Oil free vacuum pump Rocker 400 230 V, manifold MultiVac 301-MB, 3 places spin-lock, 3 x stainless steel filter funnel 100 ml, waste bottel PP 4000 ml, torch burner, MCE membrane, 47 mm, 0.45 μm, 200 pcs./PK, silicone tube (2 m) Waste bottle: PP, tube: silicone, filter holder: stainless steel Filtration for microbiology tests, chemical experiments, general laboratory filtration Funnel with spin-lock connections Filter holder: 100 ml; waste bottle: 4000 ml 34 l/min, -680 mmHg
00829 180600-22-T MultiVac 600-MB-T 230 V Oil free vacuum pump Rocker 400 230 V, manifold MultiVac 601-MB, 6 places spin-lock, 6 x stainless steel filter funnel 100 ml, waste bottle PP 4000 ml, torch burner, MCE membrane, 47 mm, 0.45 μm, 200 pcs./PK, silicone tube (2 m) Waste bottle: PP, tube: silicone, filter holder: stainless steel Filtration for microbiology tests, chemical experiments, general laboratory filtration Funnel with spin-lock connections Filter holder: 100 ml; waste bottle: 4000 ml 34 l/min, -680 mmHg
Vacuum pump Rocker 300 -680mmHg (106mbar) 25l/min - 00829 167300-22
Vacuum pump Rocker 300 -680mmHg (106mbar) 25l/min

Ideal for:

  • filtration for microbiology test
  • air sampling
  • suspended solid test
  • vacuum filtration

 

Features:

  • lubricant and oil free piston
  • no air pollution
  • maintenance-free
  • ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
  • CE, CSA and RoHs certified , IP 30 protection

 

Controller:

  • thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down

 

Vacuum pump Rocker 300 DC -650mmHg (146mbar) 25l/min - 00829 167330-00
Vacuum pump Rocker 300 DC -650mmHg (146mbar) 25l/min

Ideal for:

  • filtration for microbiology test
  • air sampling
  • suspended solid test
  • vacuum filtration

 

Features:

  • lubricant and oil free piston
  • no air pollution
  • maintenance-free
  • ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
  • CE and CSA certified

 

Controller:

  • thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down

 

Vacuum pump Rocker 400 -680 mmHg (106 mbar) 34 l/min - 00829 167400-22
Vacuum pump Rocker 400 -680 mmHg (106 mbar) 34 l/min

Ideal for:

  • filtration for microbiology test
  • air sampling
  • suspended solid test
  • vacuum filtration

 

Features:

  • lubricant and oil free piston
  • no air pollution
  • maintenance-free
  • ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
  • CE, CSA and RoHs certified, with IP 30 protection

 

Controller:

  • thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down

 

Vacuum pump Rocker 410 -735 mmHg (33 mbar) 20 l/min - 00829 167410-22
Vacuum pump Rocker 410 -735 mmHg (33 mbar) 20 l/min

Ideal for:

  • filtration for microbiology test
  • air sampling
  • suspended solid test
  • vacuum filtration

 

Features:

  • lubricant and oil free piston
  • no air pollution
  • maintenance-free
  • ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
  • CE, CSA and RoHs certified, with IP 30 protection

 

Controller:

  • thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down

 

1 From 2