The following products have been found matching your search "fluorimeter": 93

Close filters
  •  
    •  
    •  
    •  
    •  
    •  
from to
3 From 4
No results were found for the filter!
Filter holder SF52 made fo stainless steel Ø47mm
Filter holder SF52 made fo stainless steel Ø47mm

SF52 Ø47mm
Ideal for:

  • filtration requiring the sterilization such as microbiology test or use for purification of corrosive liquid, solvent, etc.

 

Artikelliste

Order number Model Version Diameter (outer) Material Ideal for Connections Capacity Stopper
00829 180100-50 SF52 filtration set, filter holder without receiver flask Filter: Ø47 mm Filter: stainless steel; funnel: stainless steel; support screen: stainless steel; support base: stainless steel; stopper: silicone Filtration requiring the sterilization such as microbiology test or use for purification of corrosive liquid, solvent, etc. Spin-lock connection Funnel: 500 ml No. 18
00829 167200-11 VF11 filtration set, complete with receiver flask Filter: Ø47 mm Filter: stainless steel; funnel: stainless steel; support screen: stainless steel; support base: stainless steel; stopper: silicone; Receiver flask: borosilicate glass Filtration requiring the sterilization such as microbiology test or use for purification of corrosive liquid, solvent, etc. Spin-lock connection Funnel: 500 ml, receiver flask: 2000 ml No. 18
Vacuum filtration system WaterVac 100 -540mmg with integrated vacuum pump
Vacuum filtration system WaterVac 100 -540mmg with integrated vacuum pump

Ideal for:

  • microbiological filtration technique for analyzing aqueous-based fluids for microbiological contamination
  • suspended solid test for municipal, surface, ground and drinking water
  • general filtration without the need of collecting filtrate

Features:

  • -540 mmHg
  • up to 0,5 l/min (liquid) or 2,2 l/min (air)
  • integrated vacuum pump
  • compact design - ideal for work benches or laminar flow hoods
  • no special suction flask or waste bottle is needed
  • available with spin-lock or stopper design
  • one push-button for easy operation
  • silicone tube (2m) for waste drain included

Artikelliste

Order number Model Version Width (Outer) Length (outer) Height (outer) Diameter (outer) Material Ideal for Connections Vacuum range
00829 190110-02 MultiVac 100 spin-lock with spin-lock 120 mm 170 mm 96 mm Filter: Ø47 mm / 50 mm Housing: SUS 304; valve plate: EPDM; diaphragm: EPDM; inlet / outlet port: SUS 316; O-ring: FKM; tube: silicone Microbiological filtration technique for analysing aqueous-based fluids for microbiological contamination, suspended solid test for municipal, surface, ground and drinking water, general filtration without the need of collection filtrate EU-plug max. -540 mmHg
00829 190120-02 120 mm Filter: ?47 mm / 50 mm EU-Anschluss Max. -540 mmHg
Filter holder Sets with vacuum pumps
Filter holder Sets with vacuum pumps

Rocker 300 & LF30

  • general filtration in laboratories
  • suspended solid test
  • microbiological tests


Rocker 300 & MF31

  • general filtration in laboratories
  • suspended solid test
  • microbiological tests


Rocker 300C & VF12

  • purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis


Chemker 300 & VF12

  • purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis

Artikelliste

Order number Model Version Material Ideal for Connections Capacity Pump performance
00829 167305-22 Rocker 300 & LF30 230 V Oil free vacuum pump Rocker 300 230 V, filtration set LF30, silicone tube (1m) Waste bottle: PC; funnel: PES General filtration in laboratories, air sampling, suspended solid test Spin-lock connection Funnel: 300 ml, receiver flask: 1200 ml 20 l/min, 106 mbar
00829 167311-22 Rocker 300 & MF31 230 V Oil free vacuum pump Rocker 300 230 V, filtration set MF31, silicone tube (1m) Receiver flask: PC; funnel: PES General filtration in laboratories, air sampling, suspended solid test magnetic connections Funnel: 300 ml, receiver flask: 1000 ml 20 l/min, 173 mbar
00829 189302-22 Rocker 300 & VF12 230 V Oil free vacuum pump Rocker 300 230 V, filtration set VF12, silicone tube (1m) Receiver flask: glass; funnel: glass Purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis Aluminium clamp connection Funnel: 300 ml, receiver flask: 1000 ml 20 l/min, 173 mbar
00829 169302-22 Chemker 300 & VF12 230 V Chemical-resistant vacuum pump Chemker 300 230 V, filtration set VF12, silicone tube (1m) Receiver flask: glass; funnel: glass Purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis Aluminium clamp connection Funnel: 300 ml, receiver flask: 1000 ml 18 l/min, 120 mbar
Extractor using lighter solvents - 15 107
Extractor using lighter solvents
Extractor, using lighter solvents, ST 29/32 - ST 14/23
Magnetic stirrer with hotplate MSH-500D digital 500°C 1500 rpm
Magnetic stirrer with hotplate MSH-500D digital 500°C 1500 rpm

Ideal for:

  • mixing of chemical, laboratory and pharmaceutical materials
  • heat-sensitive procedures in microbiology and biochemistry
  • sample drying and general lab heating applications where high temperature is needed


Features:

  • up to 500°C
  • digital display with backlight
  • high-quality solid ceramic plate 200x200 mm
  • heat-, chemical- and acid-resistant
  • shade motor for 80-1.500 rpm
  • enormous strength of magnet
  • perfect heat uniformity from the inner to the edge
  • no liquid can get into the body
  • powder-coated aluminium body
  • 30 mm stirrer bar included
  • CE certified and unique serial number for tracing


Safety mechanism:

  • hot top indicator lamp
  • high quality insulation (BTU)
  • timer 99h 59min with timer-end signal
  • error status
  • locking mode
  • operation LEDs


Controller:

  • Jog-Dial controller with touch-button for precise temperature control

Artikelliste

Order number Model Version Width (Outer) Length (outer) Height (outer) Power supply Controller Housing material Speed Heating power Plate size Plate material Temperature control resolution Temperature range Temperature accuracy Packing size
DH.WMH05020 MSH-500D Unit 230 V Unit 205 mm 345 mm 135 mm 230 V, 50/60 Hz Digital powder-coated aluminium 80 - 1.500 rpm 850 W 200 x 200 mm solid ceramic plate 0.1°C display, 0.5°C control max. 500°C ±0,3°C 450 x 280 x 160 mm
DH.WMH04020 MSH-500D Set 230 V Set 205 mm 345 mm 135 mm 230 V, 50/60 Hz Digital pulverbeschichtetes Aluminium 80 - 1.500 U/Min. 850 W 200 x 200 mm solide Keramikplatte Anzeige 0,1°C, Steuerung 0,5°C max. 500°C ±0,3°C 450 x 280 x 160 mm
Hotplate HP-500D digital, 500°C
Heizplatte HP-500D Set

Ideal for:

  • sample drying and general lab heating applications where high temperature is needed


Features:

  • up to 500°C
  • digital display with backlight
  • high-quality solid ceramic plate 200x200 mm
  • heat-, chemical- and acid-resistant
  • perfect heat uniformity from the inner to the edge
  • no liquid can get into the body
  • powder-coated aluminium body
  • CE certified and unique serial number for tracing


Safety mechanism:

  • hot top indicator lamp
  • high quality insulation (BTU)
  • timer 99h 59min with timer-end signal
  • error status
  • locking mode
  • operation LEDs


Controller:

  • Jog-Dial controller with touch-button for precise temperature control

Artikelliste

Order number Model Version Width (Outer) Length (outer) Height (outer) Version with filter Controller Housing material Heating power Plate size Plate material Temperature control resolution Temperature range Temperature accuracy
DH.WHP05020 HP-500D Unit 230V Unit 205 mm 345 mm 135 mm rectangular Digital powder-coated aluminium 850 W 200 x 200 mm solid ceramic plate 0.1°C display, 0.5°C control max. 500°C ±0.3°C
DH.WHP04020 HP-500D Set 230V Set 205 mm 345 mm 135 mm rectangular Digital powder-coated aluminium 850 W 200 x 200 mm solid ceramic plate 0.1°C display, 0.5°C control max. 500°C ±0.3°C
Chromatography sprayer complete with rubber bulb - 2 147 000 C
Chromatography sprayer complete with rubber bulb
Chromatography sprayer, complete with rubber bulb
VISCOMETERS CANNON FENSKE - 8 587 007
VISCOMETERS CANNON FENSKE
VISCOMETERS, CANNON FENSKE, L. 295 MM CAPILLARY NO.300, RANGE CST 50-200 MM2/S 0,25 K. TRANSPARENT LIQUIDS NON CALIBRATED
VISCOMETERS CANNON FENSKE - 8 587 009
VISCOMETERS CANNON FENSKE
VISCOMETERS, CANNON FENSKE, ROTUINE, L. 295 MM CAPILLARY NO.400, RANGE CST 240-12 000 1,2 K. TRANSPARENT LIQUIDS NON CALIBRATED
VISCOMETERS CANNON FENSKE - 8 587 010
VISCOMETERS CANNON FENSKE
VISCOMETERS, CANNON FENSKE, L. 295 MM CAPILLARY NO.450, RANGE CST 500-2500 2,5 K. TRANSPARENT LIQUIDS NON CALIBRATED
VISCOMETERS L. 283 MM - 8 589 001
VISCOMETERS L. 283 MM
VISCOMETERS,L. 283 MM, F. TRANSP. LIQUIDS, CAPILLARY: 0, RANGE cST 0,3-1 MMS/S K: 0,001, NON-CALIBRATED; THREE TUBES
VISCOMETERS L. 283 MM - 8 589 002
VISCOMETERS L. 283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY:0C, RANGE cST 0,6-3 MMS/S K: 0,003 NON-CALIBRATED, THREE TUBES
VISCOMETERS L. 283 MM - 8 589 003
VISCOMETERS L. 283 MM
VISCOMETERS,L.283 MM F.TRANSP.LIQUIDS CAPILLARY:0B, RANGE cST 1 - 5 MMS/S K: 0,005 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 006
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY:1B, RANGE cST 10 - 50 MMS/S K: 0,05 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 007
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY: 2, RANGE cST 20 - 100 MMS/S K: 0,1 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 008
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY: 2C, RANGE cST 60 - 300 MMS/S K: 0,3 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 009
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY:2B, RANGE cST 100-500 MMS/S K: 0,5 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 010
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY: 3, RANGE cST 200 - 1000 MMS/S K: 1,0 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 011
VISCOMETERS L.283 MM
VISCOMETERS,283 MM, F.TRANSP.LIQUIDS,CAP.3C, 600-3000 MM2/S,CONSTANT K 3,0 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 012
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY:3B, RANGE cST 1000 - 5000 MMS/S K: 5,0 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 013
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY: 4 RANGE cST 2000 -10000 MMS/S K: 10,0 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 014
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY: 4C,RANGE cST 6000-30000 MMS/S K:30,0 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 015
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY:4B, RANGE cST 10000-50000 MMS/S K: 50,0 NON-CALIBRATED, THREE TUBES
VISCOMETERS L.283 MM - 8 589 016
VISCOMETERS L.283 MM
VISCOMETERS,L.283 MM, F.TRANSP.LIQUIDS CAPILLARY:5, RANGE cST 20000-100000 MMS/S K:100,0 NON-CALIBRATED, THREE TUBES
VISCOMETERS ASTM D445 AND D446 ISO 3104 - 8 589 101
VISCOMETERS ASTM D445 AND D446 ISO 3104
VISCOMETERS ASTM D445 AND D446, ISO 3104, 3105. LENGTH APPROX. 283 MM FOR USE WITH TRANSPARENT LIQUIDS. NR.: 0, K. 0,001, RANGE cST : 0,3-1 MM2/S CALIBRATED, THREE TUBES
3 From 4