The following products have been found matching your search "gef": 77

Close filters
  •  
    •  
    •  
    •  
    •  
from to
4 From 4
No results were found for the filter!
ERLENMEYER-CAP stopper for flasks Ø 37/39 mm - 5 570 012
ERLENMEYER-CAP stopper for flasks Ø 37/39 mm

ERLENMEYER-CAP stopper, for flasks Ø 37/39 mm, sterilisable, Aluminium, anodised colour: blue, chrome- nickel steel clips clamp onto the outer walls of the vial Pack = 10 pcs.

Thermal cycler Wi-TC1000-G/-S, heating range 4°C - 105°C, standard or gradient
Thermal cycler Wi-TC1000-G/-S, heating range 4°C - 105°C, standard or gradient

 Ideal for:

  • molecular biology with applications such as sequening, gene cloning, gene expression, mutagensis
  • also in areas such as drug discovery, agriculture, food industry, etc.


Features:

  • high performance peltier and independent heating segments improving temperature control
  • auxiliary heating mechanism diminishes the “edge effect” and enhance the temperature uniformity
  • wide touchdown PCR temperature range (-9.9°C to +9.9°C) and long PCR time range (-9min 59s to +9min 59s)
  • gradient temperature setting optimizes temperature easily in the single run (Wi-TC1000-G only)
  • 7" LCD-colortouch, 800 x 480, screen with user friendly interface helps to edit programs easliy
  • wide options of consumables: common PCR tubes, 8-well PCR strips and 96-well PCR plates can be used
  • user defined file system: max. 30 segments with 99 cycles, max. 16 folder and16 files each folder

 

Safety mechanism:

  • with power off protection, automatic program recovery
  • hot Iid auto-off function at 30°C - 110°C: lf module temperature is lower than 30°C, the hot Iid function will automatically tum off

Artikelliste

Order number Model Version Width (Outer) Length (outer) Height (outer) Material Power supply Cooling time Heating time Capacity Temperature variation Temperature range Temperature accuracy
6 000 600 Wi-TC1000-S Standard 280 mm 370 mm 250 mm Adapter block material: aluminum 100V - 120V/200V - 240V, 50/60Hz 5°C/sec 5°C/sec 96 x 0.2 ml PCR tubes, 8 x 12 PCR plate or 96 well plate at 55°C <0.3°C 4°C - 105°C ±0.1°C, at 55°C ±0.3°C
6 000 500 Wi-TC1000-G gradient, gradient temperature setting range: 30°C - 99°C, Gradient range: 1°C - 42°C 280 mm 370 mm 250 mm Adapter block material: aluminum 100V - 120V/200V - 240V, 50/60Hz 5°C/sec 5°C/sec 96 x 0.2 ml PCR tubes, 8 x 12 PCR plate or 96 well plate at 55°C <0.3°C 4°C - 105°C ±0.1°C, at 55°C ±0.3°C
4 From 4