Stem thermometers DIN 16178 opal glass scale - 1 396 022
STEM THERMOMETERS, DIN 16178 OPAL GLASS SCALE, YELLOW ENAMELLED MERCURY FILLING, 0 +400¦ 5°C, L.105 MM
Stem thermometers DIN 16178 opal glass scale - 1 396 025
STEM THERMOMETERS, DIN 16178 OPAL GLASS SCALE, YELLOW ENAMELLED MERCURY FILLING, 0 +400¦ 5°C, L.405 MM
MANOMETER BENNERT - 2 504 000
MANOMETER, BENNERT, WITH ADJUSTABLE MIRROR-GLASS-SCALE, MOUNTED ON HARD WOOD BASE, COMPLETE, WITHOUT MERCURY
Precision adjusting thermometers acc. to Beckmann - 2 510 006
Precision adjusting thermometers acc. to Beckmann, (for boiling point method), NS 19/26, adjusting scale: -20+160°C, range 6 °C in 0.01 °C, capillary: transparent round, mercury filled, immersion length: 170 mm, total length: 630 mm, suitable for calbration
Drying oven SWOV Vacuum oven SmartLab 19/30/70 Liter, 200°C, 10-750 mmHg
Ideal for:
- drying, baking, conditioning, curing, out-glassing solids and liquids, vacuum embedding, moisture testing, plating and aging test
Features:
- very easy and convenient for vacuuming and venting, easy to read vacuum gauge
- high quality door sealing: high temperature grade silicone molded gasket
- superior uniformity and stability
- safety window: tempered safety glass 12T & polycarbonate 5T
- compact new body design
- stainless steel interior, powder-coated steel body and glass wool insulation
- 2x aluminium shelves included
- CE & UL/CUL certified and unique serial number for tracing
Safety mechanism:
- push alarm service to your smartphone
- overheat and over-current protection
- sensor error detection and leakage breaker
Controller:
- Smart-Lab™ controller with 4? full touch screen TFT LCD:
- WiRe™ app service, remote control system
- variable program settings
- self-diagnostic function
- automatic data recording
- data transfer to PC by USB memory
- Internet connectivity with WiFi
Recommended vacuum pump for 18.6l- and 30l-oven: Rocker 810
Recommended vacuum pump for 70l-oven: Rocker 800/Rocker 811
Artikelliste
Order number | Model | Version | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Ideal for | Heating time | Shelves | Heating power | Capacity | Power consumption | Temperature variation | Temperature control resolution | Temperature range | Temperature fluctuation | Vacuum range | Packing size | Sensor |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.SWOV03020 | SWOV-20 230 V | with Smart-LabTM controller, with vacuum inlet valve size outer Ø10 mm | 265 mm | 290 mm | 265 mm | 480 mm | 475 mm | 552 mm | Drying, baking, conditioning, curing, out-glassing solids and liquids, vacuum embedding, moisture testing, plating and aging test | 60 min. to 100°C, 90 min. to 150°C | 2 aluminium shelves included, height between shelves 87 mm | 2 x 170 W, 2 x 130 W | 18.6 l | 600 W | ±2.0°C at 100°C, ±3.0°C at 150°C | Display 1.0°C, control 1.0°C | Room temperature +5°C - 200°C | ±0.5°C at 100°C & 150°C | 10 - 750 mmHg, 0.63 mbar, 0.39 mbar/h | 585 x 580 x 795 mm | Temperature sensor PT100 |
DH.SWOV03030 | SWOV-30 230 V | with Smart-LabTM controller, with vacuum inlet valve size outer Ø10 mm | 300 mm | 330 mm | 300 mm | 515 mm | 515 mm | 587 mm | Drying, baking, conditioning, curing, out-glassing solids and liquids, vacuum embedding, moisture testing, plating and aging test | 70 min. to 100°C, 100 min. to 150°C | 2 aluminium shelves included, height between shelves 98 mm | 2 x 170 W, 2 x 130 W | 30 l | 600 W | ±2.0°C at 100°C, ±3.0°C at 150°C | Display 1.0°C, control 1.0°C | Room temperature +5°C - 200°C | ±0.5°C at 100°C & 150°C | 10 - 750 mmHg, 0.63 mbar, 0.39 mbar/h | 620 x 620 x 830 mm | Temperature sensor PT100 |
DH.SWOV03070 | SWOV-70 230 V | with Smart-LabTM controller, with vacuum inlet valve size outer Ø10 mm | 400 mm | 435 mm | 400 mm | 618 mm | 620 mm | 687 mm | Drying, baking, conditioning, curing, out-glassing solids and liquids, vacuum embedding, moisture testing, plating and aging test | 80 min. to 100°C, 100 min. to 150°C | 2 aluminium shelves included, height between shelves 133 mm | 2 x 350 W, 2 x 450 W | 70 l | 1600 W | ±2.5°C at 100°C, ±3.5°C at 150°C | Display 1.0°C, control 1.0°C | Room temperature +5°C - 200°C | ±0.5°C at 100°C & 150°C | 10 - 750 mmHg, 0.63 mbar, 0.39 mbar/h | 725 x 720 x 930 mm | Temperature sensor PT100 |
Vacuum pump Rocker 300 -680mmHg (106mbar) 25l/min - 00829 167300-22
Ideal for:
- filtration for microbiology test
- air sampling
- suspended solid test
- vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE, CSA and RoHs certified , IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 300 DC -650mmHg (146mbar) 25l/min - 00829 167330-00
Ideal for:
- filtration for microbiology test
- air sampling
- suspended solid test
- vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE and CSA certified
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 400 -680 mmHg (106 mbar) 34 l/min - 00829 167400-22
Ideal for:
- filtration for microbiology test
- air sampling
- suspended solid test
- vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE, CSA and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 410 -735 mmHg (33 mbar) 20 l/min - 00829 167410-22
Ideal for:
- filtration for microbiology test
- air sampling
- suspended solid test
- vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE, CSA and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 810 -735 mmHg (33 mbar) 50 l/min - 00829 167810-22
Ideal for:
- vacuum drying
- vacuum oven
- high volume degas
- high volume vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- CE certified
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 801 -670 mmHg (120 mbar) 68 l/min - 00829 167801-22
Ideal for:
- vacuum drying
- vacuum oven
- high volume degas
- high volume vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE certified
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 811 -735 mmHg (33 mbar) 40 l/min - 00829 167811-22
Ideal for:
- vacuum drying
- vacuum oven
- high volume degas
- high volume vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE certified
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 430 -630 mmHg (173 mbar) 28 l/min 80 psi - 00829 167430-22
Ideal for:
- filtration for microbiology test
- air sampling
- suspended solid test
- vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Chemker 300 -670 mmHg (120 mbar) 18 l/min chemical resistant (PTFE) - 00829 169300-22
Ideal for:
- vacuum filtration
- gel electrophoresis
- solid phase extraction (SPE)
- solvent purification
Features:
- high chemical resistant due to PTFE materials
- no air pollution
- maintenance-free
- quiet operation and low vibration
- direct driven motor
- CE certified
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Chemker 400 -670 mmHg (120 mbar) 33 l/min chemical resistant (PTFE) - 00829 169400-22
Ideal for:
- vacuum filtration
- gel electrophoresis
- solid phase extraction (SPE)
- solvent purification
Features:
- high chemical resistant due to PTFE materials
- no air pollution
- maintenance-free
- quiet operation and low vibration
- direct driven motor
- CE certified
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Chemker 410 -750 mmHg (13 mbar) 18 l/min chemical resistant (PTFE) - 00829 169410-22
Ideal for:
- vacuum filtration
- gel electrophoresis
- solid phase extraction (SPE)
- solvent purification
- rotary evaporator
Features:
- high chemical resistant due to PTFE materials
- no air pollution
- maintenance-free
- quiet operation and low vibration
- direct driven motor
- CE certified
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Chemker 411 -750 mmHg (13 mbar) 18 l/min with vapor trap chemical resistant (PTFE) - 00829 169411-22
Ideal for:
- vacuum filtration
- gel electrophoresis
- solid phase extraction (SPE)
- solvent purification
- rotary evaporator
Features:
- high chemical resistant due to PTFE materials
- no air pollution
- maintenance-free
- quiet operation and low vibration
- direct driven motor
- CE certified
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down