The following products have been found matching your search "hydrometers": 16

Close filters
  •  
    •  
    •  
    •  
from to
No results were found for the filter!
SET OF 14 HYDROMETERS FROM 0.600 - 1.300 G/CM3 - 8 556 100
SET OF 14 HYDROMETERS FROM 0.600 - 1.300 G/CM3
SET OF 14 HYDROMETERS FROM, 0.600 - 1.300 G/CM3
SET OF 14 HYDROMETERS FROM 1.300 - 2.000 G/CM3 - 8 556 200
SET OF 14 HYDROMETERS FROM 1.300 - 2.000 G/CM3
SET OF 14 HYDROMETERS FROM, 1.300 - 2.000 G/CM3
HYDROMETERS ACC.TO BEAUME - 8 558 202
HYDROMETERS ACC.TO BEAUME
HYDROMETERS, ACC.TO BEAUME WITHOUT THER- MOMETER, RANGE: 0-2 : 0,1 % VOL., L. 260 MM
HYDROMETERS ACC.TO BEAUME - 8 558 203
HYDROMETERS ACC.TO BEAUME
HYDROMETERS, ACC.TO BEAUME WITHOUT THER- MOMETER, RANGE: 0-3 : 0,1 % VOL.,L.260MM
SET COMPLETE OF 14 HYDROMETERS - 8 559 100
SET COMPLETE OF 14 HYDROMETERS
SET, COMPLETE OF 14 HYDROMETERS
DENSITY-HYDROMETERS 0.060¦ RANGE - 8 561 001
DENSITY-HYDROMETERS 0.060¦ RANGE
DENSITY-HYDROMETERS, 0.060¦ RANGE, RANGE 0.600-0.660 : 0.001 G/CM3
Hydrometer cylinders 500 ml - 7 005 001
Hydrometer cylinders 500 ml

Hydrometer cylinders, 500 ml:5 ml, PP, translucent, with reservoir beaker and pouring lip, moulded graduations, height 351 mm, o.Ø 73 mm

Biogen-crossflow-microfiltration-modules - 2 340 101
Biogen-crossflow-microfiltration-modules
Biogen-crossflow-microfiltration-modules type WG2PO6, housing borosilicate glass 3.3, 400 qcm, material PP hydrophobic, no. of capill. 85, cap.-i.dia.: 0.6 mm, o.dia.: 1.0 mm
Vacuum aspiration system Vacmax, integrated vacuum pump with vacuum control - 5 429 600
Vacuum aspiration system Vacmax, integrated vacuum pump with vacuum control

Ideal for:

  • designed for laboratory waste recovery and separation of liquid and solid
  • can be widely used in cell culture, DNA extraction, micro plate waste removal, and any other liquid separation or recovery


Features:

  • vacuum power can be set to different levels to achieve 1 ml/S to 15 ml/S aspiration speed (liquid 1 – 17 ml/S)
  • sensitive level sensor to prevent liquid overflow during operation
  • fully autoclavable waste collection bottle, tubing and handle.
  • lid, tubing and handle are easy to disassemble, clean and autoclave
  • wide range of adapters to fit tube, micro plate and disk plate for various tasks
  • interchangeable hand operator – tip adapters make it suitable for various tasks from single channel to 8-channel based on the applications in tube, micro plate, disk plate, etc.
  • including a hydrophobic filter 0.45 μm, Ø6 mm
  • pump noise less than 65 dB (A)
  • CE certified and unique serial number for tracing
Areometer for hydrogen peroxide H2O2 0-30% - 8 577 308
Areometer for hydrogen peroxide H2O2 0-30%

Areometer for hydrogen peroxide, H2O2, 0-30%, without thermometer

Areometer for hydrochloric acid HCI 0,40:0,5% - 8 577 306
Areometer for hydrochloric acid HCI 0,40:0,5%

Areometer for hydrochloric acid, HCI, 0-40:0.5%, with dual density scale, without thermometer

Baths WSB Shaking water bath 18/30/45 Liter 100°C ±0,1°C
Baths WSB Shaking water bath 18/30/45 Liter 100°C ±0,1°C

Ideal for:

  • direct immersion of samples for shaking in the field of biotechnology and laboratories, hybridization applications, cell cultures, cell aeration, increasing solubility rates, molecular biology assays and bacterial vultures

 

Features:

  • stainless steel interior and bath, powder-coated steel body, double painted & baked body, 20 mm polyurethane-insulation
  • high-performance shaking engine ensures best smoothly shaking motion, minimum noise and vibration
  • universal stainless steel spring rack included: for various kind of flasks and tubes (up to 2l), easy to disassemble
  • user‘s self-compensation function to control difference between real temperature and indicated temperature (±10.0°C)
  • drain valve mounted
  • backlight LCD display
  • CE certified and unique serial number for tracing

 

Safety mechanism:

  • overheat and over-current protection
  • sensor error detection

 

Controller:

  • Jog-Dial controller (turn + push)
  • digital feedback controller for precise speed control
  • digital fuzzy controller for precise temperature control

 

Artikelliste

Order number Model Version Width (inner) Length (inner) Height (inner) Width (Outer) Length (outer) Height (outer) Capacity Shaking speed Shaking stroke Power consumption Temperature range Temperature fluctuation Temperature accuracy Packing size Sensor
DH.WSB03018 WSB-18 230 V max. quantity of Erlenmeyer flasks: 6 x 250 ml, 4 x 500 ml, 1 x 1000 ml 300 mm 300 mm 200 mm 563 mm 353 mm 340 mm 18 l 20 - 250 rpm, 1 rpm-display, 1 rpm-control 20 mm (other strokes on request) 1400 W Room temperature +5°C - 100°C ±0.5°C at -20°C ±0.1°C 620 x 420 x 450 mm Temperature sensor PT100
DH.WSB03030 WSB-30 230 V max. quantity of Erlenmeyer flasks: 10 x 250 ml, 8 x 500 ml, 3 x 1000 ml 500 mm 300 mm 200 mm 763 mm 353 mm 340 mm 30 l 20 - 250 rpm, 1 rpm-display, 1 rpm-control 20 mm (other strokes on request) 1800 W Room temperature +5°C - 100°C ±0.5°C at -20°C ±0.1°C 820 x 420 x 450 mm Temperature sensor PT100
DH.WSB03045 WSB-45 230 V max. quantity of Erlenmeyer flasks: 18 x 250 ml, 15 x 500 ml, 8 x 1000 ml 600 mm 380 mm 200 mm 863 mm 433 mm 340 mm 45 l 20 - 250 rpm, 1 rpm-display, 1 rpm-control 20 mm (other strokes on request) 2400 W Room temperature +5°C - 100°C ±0.5°C at -20°C ±0.1°C 920 x 500 x 450 mm Temperature sensor PT100
Rocker RK 5-50rpm angel 6°/9°
Rocker RK 5-50rpm angel 6°/9°

Ideal for:

  • gel staining, destaining, blotting, cell culture, hybridization and washing

 

Features:

  • 5 - 50 rpm
  • 290x200 mm or 300x300 mm
  • tilt angle can be set to ±6° and ±9°
  • digital LCD display
  • smooth start and change of rocking speed while operation
  • timer for 0-99 hours
  • stainless steel platform with non-slip rubber pad included
  • optional stackable second platform available
  • 14W geared DC motor
  • CE certified and unique serial number for tracing

 

Safety mechanism:

  • timer 99h 59min with timer-end signal
  • operation LEDs
  • overload protection
  • locking mode

 

Controller:

  • programmable Jog-Shuttle controller with touch-button

 

Artikelliste

Order number Model Width (Outer) Length (outer) Height (outer) Ideal for Controller Speed Motor rating Plate size Shaking motion Packing size Angle Max. load
DH.WRK01010 RK-1D 230 V 290 mm 240 mm 150 mm Gel staining, destaining, blotting, cell culture, hybridization and washing Digital 5-50 rpm 14 W geared DC motor 290 x 200 mm (included) Rocker motion 450 x 350 x h250 mm +6° or +9° (factory default +9°) 8 kg
DH.WRK01020 RK-2D 230 V 300 mm 360 mm 155 mm Gel staining, destaining, blotting, cell culture, hybridization and washing Digital 5-50 rpm 14 W geared DC motor 300 x 300 mm (included) Rocker motion 450 x 350 x h250 mm +6° or +9° (factory default +9°) 10 kg
Rotator RT-10, 5 - 60 rpm, angle 0° - 90° - DH.WRT00010
Rotator RT-10, 5 - 60 rpm, angle 0° - 90°

Ideal for:

  • general mixing, diffusing, dialyzing, hybridization and aerating culture
  • keeping biological samples in suspension

 

Features:

  • 5 - 60 rpm
  • 0-90° angle adjustable
  • digital LCD display
  • smooth start and change of rocking speed while operation
  • timer for 0-99 hours
  • 5 different disks available
  • durable construction for long life time
  • CE certified and unique serial number for tracing

 

Safety mechanism:

  • timer 99h 59min with timer-end signal
  • operation LEDs
  • overload protection
  • locking mode

 

Controller:

  • programmable Jog-Shuttle controller with touch-button

 

Shaker SHO, orbital motion, 10-300 rpm, 230x230/350x350 mm
Shaker SHO, orbital motion, 10-300 rpm, 230x230/350x350 mm

Ideal for:

  • culturing cells to hybridization, staining and destaining gels, and combinatorial chemistry
  • hybridization, washing blots, culturing microbes

 

Features:

  • 10 - 300 rpm
  • 230x230 mm or 350x350 mm
  • digital LCD display
  • smooth start and change of shaking speed while operation
  • minimum noise
  • timer for 0-99 hours
  • multiple platforms and flask holder available
  • brushless DC motor
  • CE certified and unique serial number for tracing

 

Safety mechanism:

  • timer 99h 59min with timer-end signal
  • operation LEDs
  • overload protection
  • locking mode

 

Controller:

  • programmable Jog-Shuttle controller with touch-button

 

Artikelliste

Order number Model Version Width (Outer) Length (outer) Height (outer) Ideal for Controller Moisture range Speed Plate size Shaking motion Temperature range Packing size Max. load
DH.WSO04010 SHO-1D 230 V Amplitude: 10 mm 250 mm 330 mm 150 mm Culturing cells to hybridization, staining and destaining gels, and combinatorial chemistry, hybridization, washing blots, culturing microbes Digital, 6 programs, 10 steps 85% RH 10-300 rpm 230 x 230 mm Orbital motion at ambient temperature: +5 - 50°C 450 x 350 x h250 mm 8 kg
DH.WSO04012 SHO-2D 230 V Amplitude: 20 mm 400 mm 480 mm 160 mm Culturing cells to hybridization, staining and destaining gels, and combinatorial chemistry, hybridization, washing blots, culturing microbes Digital, 6 programs, 10 steps 85% RH 10-300 rpm 350 x 350 mm Orbital motion at ambient temperature: +5 - 50°C 580 x 500 x h250 mm 10 kg
Shaker SHR, reciprocating motion, 10 - 300 rpm, 230x230/350x350 mm - DH.WSR04022
Shaker SHR, reciprocating motion, 10 - 300 rpm, 230x230/350x350 mm

Ideal for:

  • culturing cells to hybridization, staining and destaining gels, and combinatorial chemistry
  • hybridization, washing blots, culturing microbes

 

Features:

  • 10 - 300 rpm
  • 230x230 mm or 350x350 mm
  • digital LCD display
  • smooth start and change of shaking speed while operation
  • minimum noise
  • timer for 0-99 hours
  • multiple platforms and flask holder available
  • brushless DC motor
  • CE certified and unique serial number for tracing

 

Safety mechanism:

  • timer 99h 59min with timer-end signal
  • operation LEDs
  • overload protection
  • locking mode

 

Controller:

  • programmable Jog-Shuttle controller with touch-button