The following products have been found matching your search "kohleelektrode": 8
- 6 fix-volumina from 5?l to 100?l
- compact size with an overall length of 130mm
- maximum accuracy
- feeling of a regular pipette
- two-stage plunger to ensure correct pipetting volumes
- smart tip cone design allows perfect fit for 200 ?l as well as 20 ?l tips
- fully autoclavable
- colour-code for better determination
- with quality certificate per batch (individual certificate on request)
Artikelliste
Order number | Model | Version | Autoclavable | Channels | Systematic errors witeg | Random errors witeg | Volume |
---|---|---|---|---|---|---|---|
5 405 005 | Witopet mini 5 µl | Fixed | at 121°C | 1 | ±4 % | ≤2.5 % | 5 µl |
5 405 010 | Witopet mini 10 µl | Fixed | at 121°C | 1 | ±3.2 % | ≤1.4 % | 10 µl |
5 405 020 | Witopet mini 20 µl | Fixed | at 121°C | 1 | ±3 % | ≤0.5 % | 20 µl |
5 405 025 | Witopet mini 25 µl | Fixed | at 121°C | 1 | ±1.5 % | ≤1.1 % | 25 µl |
5 405 050 | Witopet mini 50 µl | Fixed | at 121°C | 1 | ±1.5 % | ≤0.4 % | 50 µl |
5 405 090 | Witopet mini 100 µl | Fixed | at 121°C | 1 | ±1.5 % | ≤0.3 % | 100 µl |
Ideal for:
- cleaning to remove dirt, grease, waxes and oil from al laboratory instruments by ultrasonic frequency
Features:
- remote generator: power control and timer function with LCD display
- BTL sonicator installed: robust and stable running
- sweep function can realize complete cleaning by the dispersion of ultrasound
- auto optimization of frequency as various water level and temperature
- foot switch control
- temperature range from ambient to 105°C
- full set with lid, foot switch and generator
- drain mounted in the bottom
- HF frequency 40 kHz
- maximum 99 minutes cleaning time
- CE certified and unique serial number for tracing
Controller:
- digital remote controller for timer, temperature and output control
Artikelliste
Order number | Model | Ideal for | Vessel diameter | Heating power | Capacity | Power consumption | Temperature range | Ultrasound | Packing size |
---|---|---|---|---|---|---|---|---|---|
DH.WUC.N30H | WUC-N30H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | Outer: 480 x 380 x 400 mm, Inner: 400 x 300 x 250 mm | 990 W | 30 l | 4694 W, generator 600 W | Ambient to 105°C | HF-peak-out: 704 W | 620 x 520 x 640 mm |
DH.WUC.N47H | WUC-N47H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | Outer: 530 x 430 x 450 mm, Inner: 450 x 350 x 300 mm | 990 W | 47 l | 1980 W, generator 900 W | Ambient to 105°C | HF-peak-out: 990 W | 670 x 570 x 710 mm |
DH.WUC.N60H | WUC-N60H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | Outer: 530 x 430 x 450 mm, Inner: 500 x 400 x 300 mm | 990 W | 60 l | 2200 W, generator 1200 W | Ambient to 105°C | HF-peak-out: 1210 W | 720 x 620 x 710 mm |
DH.WUC.N74H | WUC-N74H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | Outer: 580 x 480 x 450 mm, Inner: 550 x 450 x 300 mm | 990 W | 74 l | 2420 W, generator 1500 W | Ambient to 105°C | HF-peak-out: 1430 W | 770 x 670 x 710 mm |
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all GL 45 laboratory bottles and more.
Artikelliste
Order number | Model | Ideal for | Connections | Accessories |
---|---|---|---|---|
8 257 201 | blue | OØ 1/8 inch tubing | 2 ports | - |
8 257 202 | blue | OØ 1/8 inch tubing | 3 ports | - |
8 257 203 | red | OØ 1/8 inch tubing | 3 ports | - |
8 257 204 | yellow | OØ 1/8 inch tubing | 4 ports | - |
8 257 205 | blue | OØ 1/16 inch tubing | 2 ports | - |
8 257 206 | red | OØ 1/16 inch tubing | 3 ports | - |
8 257 207 | yellow | OØ 1/16 inch tubing | 4 ports | - |
8 257 217 | black | OØ 1/8 inch tubing | 2 ports | 1x air valve and 1 x 1/4’’-28 fitting |
8 257 218 | black | OØ 1/8 inch tubing | 3 ports | 1x air valve and 2 x 1/4’’-28 fitting |
8 257 219 | black | OØ 1/8 inch tubing | 4 ports | 1x air valve and 3 x 1/4’’-28 fitting |
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all laboratory bottles and more.
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all GL 45 laboratory bottles and more.
Artikelliste
Order number | Model | Thread | Material | Ideal for |
---|---|---|---|---|
8 257 208 | natural | 10-32unf | OØ 1/16 inch tubing | |
8 257 209 | natural | 1/4-28 | PEEK | OØ 1/8 inch tubing |
8 257 210 | orange | 1/4-28 | PEEK | OØ 1/8 inch tubing |
8 257 211 | dark blue | 1/4-28 | PP | OØ 1/16 inch tubing |
8 257 212 | red | 1/4-28 | PP | OØ 1/8 inch tubing |
8 257 213 | dark blue | 1/4-28 | PP | OØ 1/8 inch tubing |
8 257 214 | natural | 10-32unf | PEEK | blind plug |
8 257 215 | black | 1/4-28 | PP | blind plug |
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all laboratory bottles and more.