The following products have been found matching your search "luftstromsystem": 15
Or did you mean:
luft
|
luftkuehlungssystem
|
luftzufuhrsysteme
|
luftprobenahme
|
luftstrom
|
luftzufuhrsystem
|
luftmantel
No results were found for the filter!
Air condensers cone ST 14/23 - 1 780 050
Air condensers, cone ST 14/23, tube length: 500 mm
Air condensers cone ST 19/26 - 1 782 050
Air condensers, cone ST 19/26, tube length: 500 mm
AIR CONDENSERS CONE ST 19/26 - 1 782 100
AIR CONDENSERS, CONE ST 19/26, TUBE LENGTH: 1 000 MM
Air condensers cone ST 24/29 - 1 784 050
Air condensers, cone ST 24/29, tube length: 500 mm
Air condensers cone ST 24/29 - 1 784 100
Air condensers, cone ST 24/29, tube length: 1000 mm
Air condensers cone ST 29/32 - 1 786 050
Air condensers, cone ST 29/32, tube length: 500 mm
Air condensers cone ST 29/32 - 1 786 100
Air condensers, cone ST 29/32, tube length: 1 000 mm
Clean bench WLC-V 1350/1700/2020 m²/h with HEPA Filter
Ideal for:
- protection of samples and work processes against dust and particulate contamination
Features:
- class 100 HEPA filter of efficiency up to 99.97% & 0.3 micron size (easy to exchange)
- mesh guard for HEPA filter protection
- vertical air flow-type
- optimized air flow system for uniform air flow/velocity
- 8 steps air velocity control
- UV and fluorescent lamp, external gas connection valve, internal electrical outlet
- silent and vibration-free blower (under 65 dB)
- corrosion resistant 304 stainless steel working table interior, powder-coated body and tempered safety glass sliding door for protection from UV radiation
- 99hr 59min timer
- high-quality backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- UV protection system: UV lamp is only activated when safety glass door is completely closed
Controller:
- microprocessor digital controller
- high performance touch input
Artikelliste
Order number | Model | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Filter | Ideal for | Connections | Illumination | Speed | Air volume |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WLCV1200 | WLC-V1200 230 V | 1200 mm | 660 mm | 610 mm | 1280 mm | 735 mm | 1895 mm | HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal | Protection of samples and work processes against dust and particulate contamination | 1 x air cock, 1 x gas cock, 2 x 230 V outlet | 1 x UV 20 W, 1 x FL 36 W | Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps | 1350 m2/h |
DH.WLCV1500 | WLC-V1500 230 V | 1500 mm | 660 mm | 610 mm | 1580 mm | 735 mm | 1895 mm | HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal | Protection of samples and work processes against dust and particulate contamination | 1 x air cock, 1 x gas cock, 2 x 230 V outlet | 1 UV 30 W, 1 x FL 55 W | Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps | 1700 m2/h |
DH.WLCV1800 | WLC-V1800 230 V | 1800 mm | 660 mm | 610 mm | 1880 mm | 735 mm | 1895 mm | HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal | Protection of samples and work processes against dust and particulate contamination | 1 x air cock, 1 x gas cock, 2 x 230 V outlet | 1 UV 30 W, 1 x FL 55 W | Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps | 2020 m2/h |
Air supply system Rocker 440 40-60 psi 25 l/min - 00829 167440-22
Ideal for:
- fermenter
- bioreactor
- gas chromatography
Features:
- no air pollution
- maintenance-free
- quiet operation and low vibration
- direct driven motor
- air outlet filter device for filtering particles, moisture and supply clean air
- CE, CSA and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum filtration system WaterVac 100 -540mmg with integrated vacuum pump
Ideal for:
- microbiological filtration technique for analyzing aqueous-based fluids for microbiological contamination
- suspended solid test for municipal, surface, ground and drinking water
- general filtration without the need of collecting filtrate
Features:
- -540 mmHg
- up to 0,5 l/min (liquid) or 2,2 l/min (air)
- integrated vacuum pump
- compact design - ideal for work benches or laminar flow hoods
- no special suction flask or waste bottle is needed
- available with spin-lock or stopper design
- one push-button for easy operation
- silicone tube (2m) for waste drain included
Artikelliste
Order number | Model | Version | Width (Outer) | Length (outer) | Height (outer) | Diameter (outer) | Material | Ideal for | Connections | Vacuum range |
---|---|---|---|---|---|---|---|---|---|---|
00829 190110-02 | MultiVac 100 spin-lock | with spin-lock | 120 mm | 170 mm | 96 mm | Filter: Ø47 mm / 50 mm | Housing: SUS 304; valve plate: EPDM; diaphragm: EPDM; inlet / outlet port: SUS 316; O-ring: FKM; tube: silicone | Microbiological filtration technique for analysing aqueous-based fluids for microbiological contamination, suspended solid test for municipal, surface, ground and drinking water, general filtration without the need of collection filtrate | EU-plug | max. -540 mmHg |
00829 190120-02 | 120 mm | Filter: ?47 mm / 50 mm | EU-Anschluss | Max. -540 mmHg |
Compressor Rocker 320 80/100 psi 12 l/min - 00829 167320-22
Ideal for:
- aeration
- pressure filtration
Features:
- no air pollution
- maintenance-free
- quiet operation and low vibration
- direct driven motor
- air outlet filter device for filtering particles, moisture and supply clean air
- CE, CSA and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Compressor Rocker 420 80/100 psi 25 l/min - 00829 167420-22
Ideal for:
- aeration
- pressure filtration
Features:
- no air pollution
- maintenance-free
- quiet operation and low vibration
- direct driven motor
- air outlet filter device for filtering particles, moisture and supply clean air
- CE, CSA and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Diaphragm Vacuum pump for Air Gases and Vapors - 2 600 034
Diaphragm Vacuum pump for Air, Gases and Vapors, pump speed: 20l/min, Ultimate Vaccum: 7 mbar abs, Operating pressure: 1 bar g, connectors for tube: outter-Ø 10 mm, permissible gas and ambient temperature: +5 - +40 °C, overall dimensions: 270 x 180 x 220 mm, Power source: AC 230V 50/60Hz, 1,2A, weight: 9,3 kg
Air jacket for apparatuses for determination of molecular weights - 2 510 001
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR BOILING METHOD) -AIR JACKET
Air jacket for apparatuses for determination of molecular weights - 2 512 004
Spare parts for apparatuses for determination of molecular weights, acc. to Beckmann: (for freezing point method) -air jacket with ST 45/40