The following products have been found matching your search "mobile phase": 6
VF5 & VF8 Ø25mm
Ideal for:
- small volume vacuum filtration for biological or particulate contamination analysis
VF6 & VF7 Ø47mm
Ideal for:
- solvent purification and general filtration for microbiology, suspended solid analysis etc.
VF3 & VF16 Ø47mm / Ø90mm
Ideal for:
- purification of organic, corrosive liquid such as solvent, mobile phase for HPLC, GC and AA analysis
Artikelliste
Order number | Model | Version | Diameter (outer) | Material | Ideal for | Capacity | Stopper |
---|---|---|---|---|---|---|---|
00829 167200-05 | VF5 filtration set, complete | with receiver flask | Filter: Ø25 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass | Small volume vacuum filtration for biological or particulate contamination analysts | Funnel: 15 ml, receiver flask: 125 ml | No. 5 |
00829 167120-32 | VF5 filtration set, filter holder | without receiver flask | Filter: Ø25 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone | Small volume vacuum filtration for biological or particulate contamination analysts | Funnel: 15 ml | No. 5 |
00829 167200-08 | VF8 filtration set, complete | with receiver flask | Filter: Ø25 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass | Small volume vacuum filtration for biological or particulate contamination analysts | Funnel: 15 ml, receiver flask: 125 ml | No. 5 |
00829 167120-34 | VF8 filtration set, filter holder | without receiver flask | Filter: Ø25 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone | Small volume vacuum filtration for biological or particulate contamination analysts | Funnel: 15 ml | No. 5 |
00829 167200-06 | VF6 filtration set, complete | with receiver flask | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass; fixing sucker: silicone | Solvent purification and general filtration for microbiology, suspended solid analysis etc. | Funnel: 300 ml, receiver flask: 1000 ml | No. 8 |
00829 167120-31 | VF6 filtration set, filter holder | without receiver flask and fixing sucker | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone | Solvent purification and general filtration for microbiology, suspended solid analysis etc. | Funnel: 300 ml | No. 8 |
00829 167200-07 | VF7 filtration set, complete | with receiver flask and fixing sucker | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass; fixing sucker: silicone | Solvent purification and general filtration for microbiology, suspended solid analysis etc. | Funnel: 300 ml, receiver flask: 1000 ml | No. 8 |
00829 167120-33 | VF7 filtration set , filter holder | without receiver flask and fixing sucker | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone | Solvent purification and general filtration for microbiology, suspended solid analysis etc. | Funnel: 300 ml | No. 8 |
00829 167200-03 | VF3 filtration set, complete | with receiver flask and fixing sucker | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, suction cap: borosilicate glass; receiver flask: borosilicate glass; fixing sucker: silicone | Purification of organic, corrosive liquid such as solvent (mobile phase) for HPLC analysis | Funnel: 300 ml, receiver flask: 1000 ml | |
00829 167120-30 | VF3 filtration set, filter holder | without receiver flask and fixing sucker | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, suction cap: borosilicate glass | Purification of organic, corrosive liquid such as solvent (mobile phase) for HPLC analysis | Funnel: 300 ml | |
00829 167200-16 | VF16 filtration set, complete | with receiver flask | Filter: Ø90 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: PTFE coated; gasket: PTFE; suction cap: borosilicate glass; receiver flask: borosilicate glass | Purification of organic, corrosive liquid such as solvent, mobile phase for HPLC, GC and AA analysis | Funnel: 1000 ml, receiver flask: 5000 ml |
Rocker 300 & LF30
- general filtration in laboratories
- suspended solid test
- microbiological tests
Rocker 300 & MF31
- general filtration in laboratories
- suspended solid test
- microbiological tests
Rocker 300C & VF12
- purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis
Chemker 300 & VF12
- purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis
Artikelliste
Order number | Model | Version | Material | Ideal for | Connections | Capacity | Pump performance |
---|---|---|---|---|---|---|---|
00829 167305-22 | Rocker 300 & LF30 230 V | Oil free vacuum pump Rocker 300 230 V, filtration set LF30, silicone tube (1m) | Waste bottle: PC; funnel: PES | General filtration in laboratories, air sampling, suspended solid test | Spin-lock connection | Funnel: 300 ml, receiver flask: 1200 ml | 20 l/min, 106 mbar |
00829 167311-22 | Rocker 300 & MF31 230 V | Oil free vacuum pump Rocker 300 230 V, filtration set MF31, silicone tube (1m) | Receiver flask: PC; funnel: PES | General filtration in laboratories, air sampling, suspended solid test | magnetic connections | Funnel: 300 ml, receiver flask: 1000 ml | 20 l/min, 173 mbar |
00829 189302-22 | Rocker 300 & VF12 230 V | Oil free vacuum pump Rocker 300 230 V, filtration set VF12, silicone tube (1m) | Receiver flask: glass; funnel: glass | Purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis | Aluminium clamp connection | Funnel: 300 ml, receiver flask: 1000 ml | 20 l/min, 173 mbar |
00829 169302-22 | Chemker 300 & VF12 230 V | Chemical-resistant vacuum pump Chemker 300 230 V, filtration set VF12, silicone tube (1m) | Receiver flask: glass; funnel: glass | Purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis | Aluminium clamp connection | Funnel: 300 ml, receiver flask: 1000 ml | 18 l/min, 120 mbar |
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all GL 45 laboratory bottles and more.
Artikelliste
Order number | Model | Ideal for | Connections | Accessories |
---|---|---|---|---|
8 257 201 | blue | OØ 1/8 inch tubing | 2 ports | - |
8 257 202 | blue | OØ 1/8 inch tubing | 3 ports | - |
8 257 203 | red | OØ 1/8 inch tubing | 3 ports | - |
8 257 204 | yellow | OØ 1/8 inch tubing | 4 ports | - |
8 257 205 | blue | OØ 1/16 inch tubing | 2 ports | - |
8 257 206 | red | OØ 1/16 inch tubing | 3 ports | - |
8 257 207 | yellow | OØ 1/16 inch tubing | 4 ports | - |
8 257 217 | black | OØ 1/8 inch tubing | 2 ports | 1x air valve and 1 x 1/4’’-28 fitting |
8 257 218 | black | OØ 1/8 inch tubing | 3 ports | 1x air valve and 2 x 1/4’’-28 fitting |
8 257 219 | black | OØ 1/8 inch tubing | 4 ports | 1x air valve and 3 x 1/4’’-28 fitting |
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all laboratory bottles and more.
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all GL 45 laboratory bottles and more.
Artikelliste
Order number | Model | Thread | Material | Ideal for |
---|---|---|---|---|
8 257 208 | natural | 10-32unf | OØ 1/16 inch tubing | |
8 257 209 | natural | 1/4-28 | PEEK | OØ 1/8 inch tubing |
8 257 210 | orange | 1/4-28 | PEEK | OØ 1/8 inch tubing |
8 257 211 | dark blue | 1/4-28 | PP | OØ 1/16 inch tubing |
8 257 212 | red | 1/4-28 | PP | OØ 1/8 inch tubing |
8 257 213 | dark blue | 1/4-28 | PP | OØ 1/8 inch tubing |
8 257 214 | natural | 10-32unf | PEEK | blind plug |
8 257 215 | black | 1/4-28 | PP | blind plug |
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all laboratory bottles and more.