Close filters
  •  
    •  
    •  
    •  
from to
No results were found for the filter!
Air jacket for apparatuses for determination of molecular weights - 2 510 001
Air jacket for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR BOILING METHOD) -AIR JACKET
Boiling tube for apparatuses for determination of molecular weights - 2 510 002
Boiling tube for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS ACC. TO BECKMANN: (FOR BOILING METHOD) -BOILING TUBE WITH 2 ST 19/26, 2 ST 14/23 AND 1 ST 10/19
Condenser for apparatuses for determination of molecular weights - 2 510 003
Condenser for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR BOILING METHOD) -CONDENSER WITH ST 19/26
Drying tube for apparatuses for determination of molecular weights - 2 510 004
Drying tube for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR BOILING METHOD) -DRYING TUBE WITH ST 10/19
Hollow stopper for apparatuses for determination of molecular weights - 2 510 005
Hollow stopper for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR BOILING METHOD) -HOLLOW STOPPER ST 14/23
Vessel for freezing mixture for apparatuses for determination of molecular weights - 2 512 001
Vessel for freezing mixture for apparatuses for determination of molecular weights
Spare parts for apparatuses for determination of molecular weights, acc. to Beckmann: (for freezing point method) -vessel for freezing mixture with cover
Base for apparatuses for determination of molecular weights - 2 512 002
Base for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR FREEZING POINT METHOD) -BASE
Freezing tube for apparatuses for determination of molecular weights - 2 512 003
Freezing tube for apparatuses for determination of molecular weights
Spare parts for apparatuses for determination of molecular weights, acc. to Beckmann: (for freezing point method) -freezing tube with 2 ST 45/40 and ST 14/23
Air jacket for apparatuses for determination of molecular weights - 2 512 004
Air jacket for apparatuses for determination of molecular weights
Spare parts for apparatuses for determination of molecular weights, acc. to Beckmann: (for freezing point method) -air jacket with ST 45/40
Connection tube for apparatuses for determination of molecular weights - 2 512 005
Connection tube for apparatuses for determination of molecular weights
Spare parts for apparatuses for determination of molecular weights, acc. to Beckmann: (for freezing point method) -connection tubes with ST 45/40, ST 19/26 and ST 7/16
Drying tube for apparatuses for determination of molecular weights - 2 512 006
Drying tube for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR FREEZING POINT METHOD) -DRYING TUBE WITH ST 7/16
Thermometer for apparatuses for determination of molecular weights - 2 512 007
Thermometer for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR FREEZING POINT METHOD) -THERMOMETER,BECKMANN, 5-6 °C:O,O1 °C, WITH ST 19/26
Filling tube for apparatuses for determination of molecular weights - 2 512 008
Filling tube for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR FREEZING POINT METHOD) -FILLING TUBE
Tube and pin for apparatuses for determination of molecular weights - 2 512 009
Tube and pin for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR FREEZING POINT METHOD) -TUBE AND PIN
Metal stirrer for apparatuses for determination of molecular weights - 2 512 010
Metal stirrer for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR FREEZING POINT METHOD) -STIRRER METAL
Syphon for apparatuses for determination of molecular weights - 2 512 011
Syphon for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR FREEZING POINT METHOD) -SYPHON
Thermometer for apparatuses for determination of molecular weights - 2 512 012
Thermometer for apparatuses for determination of molecular weights
SPARE PARTS FOR APPARATUSES FOR DETERMINATION OF MOLECULAR WEIGHTS, ACC. TO BECKMANN: (FOR FREEZING METHOD) -THERMOMETER - 35 °C TO +50 °C
Glass stirrer for apparatuses for determination of molecular weights - 2 512 013
Glass stirrer for apparatuses for determination of molecular weights
Spare parts for apparatuses for determination of molecular weights, acc. to Beckmann: (for freezing point method) -stirrer made of glass
Baths WSB Shaking water bath 18/30/45 Liter 100°C ±0,1°C
Baths WSB Shaking water bath 18/30/45 Liter 100°C ±0,1°C

Ideal for:

  • direct immersion of samples for shaking in the field of biotechnology and laboratories, hybridization applications, cell cultures, cell aeration, increasing solubility rates, molecular biology assays and bacterial vultures

 

Features:

  • stainless steel interior and bath, powder-coated steel body, double painted & baked body, 20 mm polyurethane-insulation
  • high-performance shaking engine ensures best smoothly shaking motion, minimum noise and vibration
  • universal stainless steel spring rack included: for various kind of flasks and tubes (up to 2l), easy to disassemble
  • user‘s self-compensation function to control difference between real temperature and indicated temperature (±10.0°C)
  • drain valve mounted
  • backlight LCD display
  • CE certified and unique serial number for tracing

 

Safety mechanism:

  • overheat and over-current protection
  • sensor error detection

 

Controller:

  • Jog-Dial controller (turn + push)
  • digital feedback controller for precise speed control
  • digital fuzzy controller for precise temperature control

 

Artikelliste

Order number Model Version Width (inner) Length (inner) Height (inner) Width (Outer) Length (outer) Height (outer) Capacity Shaking speed Shaking stroke Power consumption Temperature range Temperature fluctuation Temperature accuracy Packing size Sensor
DH.WSB03018 WSB-18 230 V max. quantity of Erlenmeyer flasks: 6 x 250 ml, 4 x 500 ml, 1 x 1000 ml 300 mm 300 mm 200 mm 563 mm 353 mm 340 mm 18 l 20 - 250 rpm, 1 rpm-display, 1 rpm-control 20 mm (other strokes on request) 1400 W Room temperature +5°C - 100°C ±0.5°C at -20°C ±0.1°C 620 x 420 x 450 mm Temperature sensor PT100
DH.WSB03030 WSB-30 230 V max. quantity of Erlenmeyer flasks: 10 x 250 ml, 8 x 500 ml, 3 x 1000 ml 500 mm 300 mm 200 mm 763 mm 353 mm 340 mm 30 l 20 - 250 rpm, 1 rpm-display, 1 rpm-control 20 mm (other strokes on request) 1800 W Room temperature +5°C - 100°C ±0.5°C at -20°C ±0.1°C 820 x 420 x 450 mm Temperature sensor PT100
DH.WSB03045 WSB-45 230 V max. quantity of Erlenmeyer flasks: 18 x 250 ml, 15 x 500 ml, 8 x 1000 ml 600 mm 380 mm 200 mm 863 mm 433 mm 340 mm 45 l 20 - 250 rpm, 1 rpm-display, 1 rpm-control 20 mm (other strokes on request) 2400 W Room temperature +5°C - 100°C ±0.5°C at -20°C ±0.1°C 920 x 500 x 450 mm Temperature sensor PT100
Gel documentation system WGD20 portable with camera and software
Gel documentation system WGD20 portable with camera and software

Ideal for:

  • DNA, RNA gel imaging capture and analysis

Features:

  • the most cost-effective system
  • high precise and large caliber optical lens with zoom, focus and iris control
  • digital CCD camera (resolution 1360x1024, 1.5 m pixel) with portable darkroom10-bit CCD, available for 8-bit grey level image capturing
  • very compact portable darkroom system for highest flexibility
  • existing transilluminator can be used
  • USB 2.0 interface for real-time images and data transfer
  • power supply via USB
  • WiseCapture II™ software: easy and fast view, capture and save gel images (included)
  • TotalLab™ Quant software (WGD-20S): fully automatic, single button press complete image analysis in interesting area
  • CE certified and unique serial number for tracing

Artikelliste

Order number Model Width (Outer) Length (outer) Height (outer) Ideal for Connections Temperature range Packing size Sensor
DH.WGD00020 WGD-20 260 mm 260 mm 430 mm DNA, RNA gel imaging capture and analysis USB 2.0 Operation temperature -10°C to +50°C 400 x 350 x 510 mm 1/2“ CCD
DH.WGD00024 WGD-20S 260 mm 260 mm 430 mm DNA, RNA gel imaging capture and analysis USB 2.0 Operation temperature -10°C to +50°C 400 x 350 x 510 mm 1/2“ CCD
Thermal cycler Wi-TC1000-G/-S, heating range 4°C - 105°C, standard or gradient
Thermal cycler Wi-TC1000-G/-S, heating range 4°C - 105°C, standard or gradient

 Ideal for:

  • molecular biology with applications such as sequening, gene cloning, gene expression, mutagensis
  • also in areas such as drug discovery, agriculture, food industry, etc.


Features:

  • high performance peltier and independent heating segments improving temperature control
  • auxiliary heating mechanism diminishes the “edge effect” and enhance the temperature uniformity
  • wide touchdown PCR temperature range (-9.9°C to +9.9°C) and long PCR time range (-9min 59s to +9min 59s)
  • gradient temperature setting optimizes temperature easily in the single run (Wi-TC1000-G only)
  • 7" LCD-colortouch, 800 x 480, screen with user friendly interface helps to edit programs easliy
  • wide options of consumables: common PCR tubes, 8-well PCR strips and 96-well PCR plates can be used
  • user defined file system: max. 30 segments with 99 cycles, max. 16 folder and16 files each folder

 

Safety mechanism:

  • with power off protection, automatic program recovery
  • hot Iid auto-off function at 30°C - 110°C: lf module temperature is lower than 30°C, the hot Iid function will automatically tum off

Artikelliste

Order number Model Version Width (Outer) Length (outer) Height (outer) Material Power supply Cooling time Heating time Capacity Temperature variation Temperature range Temperature accuracy
6 000 600 Wi-TC1000-S Standard 280 mm 370 mm 250 mm Adapter block material: aluminum 100V - 120V/200V - 240V, 50/60Hz 5°C/sec 5°C/sec 96 x 0.2 ml PCR tubes, 8 x 12 PCR plate or 96 well plate at 55°C <0.3°C 4°C - 105°C ±0.1°C, at 55°C ±0.3°C
6 000 500 Wi-TC1000-G gradient, gradient temperature setting range: 30°C - 99°C, Gradient range: 1°C - 42°C 280 mm 370 mm 250 mm Adapter block material: aluminum 100V - 120V/200V - 240V, 50/60Hz 5°C/sec 5°C/sec 96 x 0.2 ml PCR tubes, 8 x 12 PCR plate or 96 well plate at 55°C <0.3°C 4°C - 105°C ±0.1°C, at 55°C ±0.3°C