Stirring thermometers, solid stem, Di- Fico grad. filled with organic liquids -35 + 50¦C, DIA. 6-7 mm, L. 260 mm
Precision laboratory thermometer, not enamelled, for officially testing 0 +51 °C : 0,1, O. D. 9 mm, length: 400 mm, with organic filling
Precision laboratory thermometer, not enamelled, opal glass scale for officially testing, +47+101°C:0,1, Ø 9 mm, length: 400 mm, with organic filling
ASTM-Thermometer (solid stem), with Celsius -scale range, white enamelled, ASTM Type: Solidification point, ASTM-No. 91°C, +20 + 50:0,1°C, organic filling
Ideal for:
- growth of organisms and plants, stability and endurance testing of materials, environmental simulations
- stability product self-life QC testing
Features:
- stability product self-life QC testing
- 3-sided light bank system: intensity of light is controlled by 8 levels and displayed on LCD
- inner tempered glass door with silicone packing offers easy observation without door opening
- PE-coated wire shelves included (4 or 8 acc. to model)
- 3-sided magnetic doors with light banks
- stainless steel interior and powder-coated body
- CE certified and unique serial number for tracing
Safety mechanism:
- push alarm service to your smartphone
- overheat and over-current protection
- sensor error detection and leakage breaker
Controller:
- Smart-Lab™ controller with 7? full touch screen TFT LCD:
- WiRe™ app service, remote control system
- variable program settings
- self-diagnostic function and interactive temperature graph
- automatic data recording and password protection
- data transfer to PC by USB memory
- digital calibration (offset function)
- min-/max-temperature memory & program function
Artikelliste
Order number | Model | Version | Width (inner) | Length (inner) | Bore | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Thread | Ideal for | Cooling time | Heating time | Humidifier | Illumination | Shelves | Moisture range | Heating power | Capacity | Compressor | Refrigerant | Power consumption | Temperature range | Temperature fluctuation | Temperature accuracy | Packing size | Recovery time | Angle | Accessories | Humidity accuracy | Humidity stability | Sensor |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.SWGC00450 | SWGC-450 230 V | 1 door, not available in Europe | 650 mm | 700 mm | 14 x FPL 55 W, 0 bis 12.000 Lux " | 1050 mm | 850 mm | 1090 mm | 1965 mm | 435 kg | Growth of organisms and plants, stability and endurance testing of materials, environmental simulations, stability product self-life QC testing | 13 min. (0% illumination) / 15 min. (100% illumination) | 11 min. (0% illumination) / 9 min. (100% illumination) | Evaporation by fan with heater | 3 x light banks: left, right, front; 14 x FPL 55 W, 0 to 12000 Lux | 4 PE-coated steel wire shelves (16 kg/shelf) | ±1% | 1500 W | 432 l | 370 W | R-404A (CFC-free refrigerant) | 4800 W | 10°C - +60°C | ±0.5°C at 10°C, ±0.5°C at 25°C (0% illumination) / ±1°C at 10°C, ±1°C at 25°C (100% illumination) | ±1°C at 20°C | 1400 x 1220 x 2210 mm | 3 min. to 10°C, 1 min. to 37°C (0% illumination); 5 min. to 10°C, 1 min. to 37°C (100% illumination) | "3 Min. bei 10°C, 1 Min. bei 37°C (0% Beleuchtung) | 5 Min. bei 10°C, 1 Min. bei 37°C (100% Beleuchtung)" | ±1% | ±3% at 60°C | Temperature sensor PT100 |
DH.SWGC01000 | SWGC-1000 230 V | 2 doors, not available in Europe | 1200 mm | 790 mm | 28 x FPL 55 W, 0 bis 15.000 Lux " | 1050 mm | 1200 mm | 1150 mm | 1965 mm | 585 kg | Growth of organisms and plants, stability and endurance testing of materials, environmental simulations, stability product self-life QC testing | 13 min. (0% illumination) / 15 min. (100% illumination) | 11 min. (0% illumination) / 9 min. (100% illumination) | Evaporation by fan with heater | 3 x light banks: left, right, front; 28 x FPL 55 W, 0 to 15000 Lux | 8 PE-coated steel wire shelves (16 kg/shelf) | ±1% | 3000 W | 864 l | 750 W | R-404A (CFC-free refrigerant) | 6500 W | 10°C - +60°C | ±0.5°C at 10°C, ±0.5°C at 25°C (0% illumination) / ±1°C at 10°C, ±1°C at 25°C (100% illumination) | ±1°C at 20°C | 1600 x 1500 x 2200 mm | 3 min. to 10°C, 1 min. to 37°C (0% illumination); 5 min. to 10°C, 1 min. to 37°C (100% illumination) | "3 Min. bei 10°C, 1 Min. bei 37°C (0% Beleuchtung) | 5 Min. bei 10°C, 1 Min. bei 37°C (100% Beleuchtung)" | ±1% | ±3% at 60°C | Temperature sensor PT100 |
DH.SWGC60450 | SWGC-450 3 Phase | 1 door | 650 mm | 700 mm | 14 x FPL 55 W, 0 bis 12.000 Lux " | 1050 mm | 850 mm | 1090 mm | 1965 mm | 435 kg | Growth of organisms and plants, stability and endurance testing of materials, environmental simulations, stability product self-life QC testing | 13 min. (0% illumination) / 15 min. (100% illumination) | 11 min. (0% illumination) / 9 min. (100% illumination) | Evaporation by fan with heater | 3 x light banks: left, right, front; 14 x FPL 55 W, 0 to 12000 Lux | 4 PE-coated steel wire shelves (16 kg/shelf) | ±1% | 1500 W | 432 l | 370 W | R-404A (CFC-free refrigerant) | 4800 W | 10°C - +60°C | ±0.5°C at 10°C, ±0.5°C at 25°C (0% illumination) / ±1°C at 10°C, ±1°C at 25°C (100% illumination) | ±1°C at 20°C | 1400 x 1220 x 2210 mm | 3 min. to 10°C, 1 min. to 37°C (0% illumination); 5 min. to 10°C, 1 min. to 37°C (100% illumination) | "3 Min. bei 10°C, 1 Min. bei 37°C (0% Beleuchtung) | 5 Min. bei 10°C, 1 Min. bei 37°C (100% Beleuchtung)" | ±1% | ±3% at 60°C | Temperature sensor PT100 |
DH.SWGC61000 | SWGC-1000 3 Phase | 2 doors | 1200 mm | 790 mm | 28 x FPL 55 W, 0 bis 15.000 Lux " | 1050 mm | 1200 mm | 1150 mm | 1965 mm | 585 kg | Growth of organisms and plants, stability and endurance testing of materials, environmental simulations, stability product self-life QC testing | 13 min. (0% illumination) / 15 min. (100% illumination) | 11 min. (0% illumination) / 9 min. (100% illumination) | Evaporation by fan with heater | 3 x light banks: left, right, front; 28 x FPL 55 W, 0 to 15000 Lux | 8 PE-coated steel wire shelves (16 kg/shelf) | ±1% | 3000 W | 864 l | 750 W | R-404A (CFC-free refrigerant) | 6500 W | 10°C - +60°C | ±0.5°C at 10°C, ±0.5°C at 25°C (0% illumination) / ±1°C at 10°C, ±1°C at 25°C (100% illumination) | ±1°C at 20°C | 1600 x 1500 x 2200 mm | 3 min. to 10°C, 1 min. to 37°C (0% illumination); 5 min. to 10°C, 1 min. to 37°C (100% illumination) | "3 Min. bei 10°C, 1 Min. bei 37°C (0% Beleuchtung) | 5 Min. bei 10°C, 1 Min. bei 37°C (100% Beleuchtung)" | ±1% | ±3% at 60°C | Temperature sensor PT100 |
VF5 & VF8 Ø25mm
Ideal for:
- small volume vacuum filtration for biological or particulate contamination analysis
VF6 & VF7 Ø47mm
Ideal for:
- solvent purification and general filtration for microbiology, suspended solid analysis etc.
VF3 & VF16 Ø47mm / Ø90mm
Ideal for:
- purification of organic, corrosive liquid such as solvent, mobile phase for HPLC, GC and AA analysis
Artikelliste
Order number | Model | Version | Diameter (outer) | Material | Ideal for | Capacity | Stopper |
---|---|---|---|---|---|---|---|
00829 167200-05 | VF5 filtration set, complete | with receiver flask | Filter: Ø25 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass | Small volume vacuum filtration for biological or particulate contamination analysts | Funnel: 15 ml, receiver flask: 125 ml | No. 5 |
00829 167120-32 | VF5 filtration set, filter holder | without receiver flask | Filter: Ø25 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone | Small volume vacuum filtration for biological or particulate contamination analysts | Funnel: 15 ml | No. 5 |
00829 167200-08 | VF8 filtration set, complete | with receiver flask | Filter: Ø25 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass | Small volume vacuum filtration for biological or particulate contamination analysts | Funnel: 15 ml, receiver flask: 125 ml | No. 5 |
00829 167120-34 | VF8 filtration set, filter holder | without receiver flask | Filter: Ø25 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone | Small volume vacuum filtration for biological or particulate contamination analysts | Funnel: 15 ml | No. 5 |
00829 167200-06 | VF6 filtration set, complete | with receiver flask | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass; fixing sucker: silicone | Solvent purification and general filtration for microbiology, suspended solid analysis etc. | Funnel: 300 ml, receiver flask: 1000 ml | No. 8 |
00829 167120-31 | VF6 filtration set, filter holder | without receiver flask and fixing sucker | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support base: borosilicate glass; stopper: silicone | Solvent purification and general filtration for microbiology, suspended solid analysis etc. | Funnel: 300 ml | No. 8 |
00829 167200-07 | VF7 filtration set, complete | with receiver flask and fixing sucker | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone; receiver flask: borosilicate glass; fixing sucker: silicone | Solvent purification and general filtration for microbiology, suspended solid analysis etc. | Funnel: 300 ml, receiver flask: 1000 ml | No. 8 |
00829 167120-33 | VF7 filtration set , filter holder | without receiver flask and fixing sucker | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: stainless steel, gasket: PTFE; support base: borosilicate glass; stopper: silicone | Solvent purification and general filtration for microbiology, suspended solid analysis etc. | Funnel: 300 ml | No. 8 |
00829 167200-03 | VF3 filtration set, complete | with receiver flask and fixing sucker | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, suction cap: borosilicate glass; receiver flask: borosilicate glass; fixing sucker: silicone | Purification of organic, corrosive liquid such as solvent (mobile phase) for HPLC analysis | Funnel: 300 ml, receiver flask: 1000 ml | |
00829 167120-30 | VF3 filtration set, filter holder | without receiver flask and fixing sucker | Filter: Ø47 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, suction cap: borosilicate glass | Purification of organic, corrosive liquid such as solvent (mobile phase) for HPLC analysis | Funnel: 300 ml | |
00829 167200-16 | VF16 filtration set, complete | with receiver flask | Filter: Ø90 mm | Filter: borosilicate glass; funnel: borosilicate glass; clamp: anodized aluminium, support screen: PTFE coated; gasket: PTFE; suction cap: borosilicate glass; receiver flask: borosilicate glass | Purification of organic, corrosive liquid such as solvent, mobile phase for HPLC, GC and AA analysis | Funnel: 1000 ml, receiver flask: 5000 ml |
Rocker 300 & LF30
- general filtration in laboratories
- suspended solid test
- microbiological tests
Rocker 300 & MF31
- general filtration in laboratories
- suspended solid test
- microbiological tests
Rocker 300C & VF12
- purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis
Chemker 300 & VF12
- purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis
Artikelliste
Order number | Model | Version | Material | Ideal for | Connections | Capacity | Pump performance |
---|---|---|---|---|---|---|---|
00829 167305-22 | Rocker 300 & LF30 230 V | Oil free vacuum pump Rocker 300 230 V, filtration set LF30, silicone tube (1m) | Waste bottle: PC; funnel: PES | General filtration in laboratories, air sampling, suspended solid test | Spin-lock connection | Funnel: 300 ml, receiver flask: 1200 ml | 20 l/min, 106 mbar |
00829 167311-22 | Rocker 300 & MF31 230 V | Oil free vacuum pump Rocker 300 230 V, filtration set MF31, silicone tube (1m) | Receiver flask: PC; funnel: PES | General filtration in laboratories, air sampling, suspended solid test | magnetic connections | Funnel: 300 ml, receiver flask: 1000 ml | 20 l/min, 173 mbar |
00829 189302-22 | Rocker 300 & VF12 230 V | Oil free vacuum pump Rocker 300 230 V, filtration set VF12, silicone tube (1m) | Receiver flask: glass; funnel: glass | Purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis | Aluminium clamp connection | Funnel: 300 ml, receiver flask: 1000 ml | 20 l/min, 173 mbar |
00829 169302-22 | Chemker 300 & VF12 230 V | Chemical-resistant vacuum pump Chemker 300 230 V, filtration set VF12, silicone tube (1m) | Receiver flask: glass; funnel: glass | Purification of organic, corrosive liquids such as solvent (mobile phase) for HPLC analysis | Aluminium clamp connection | Funnel: 300 ml, receiver flask: 1000 ml | 18 l/min, 120 mbar |