No results were found for the filter!
Laboratory spatula PA 150 mm double - 7 153 201
Laboratory spatula, PA, Length 150 mm, double version, suitable for food, Pack = 5 pcs
Laboratory spatula PA 180 mm double - 7 153 202
Laboratory spatula, PA, Length 180 mm, double version, suitable for food, Pack = 5 pcs
Laboratory spatula PA 180 mm with spoon - 7 153 203
Laboratory spatula, PA, Length 180 mm, with spoon, suitable for food, Pack = 10 pcs
Laboratory spatula PA 210 mm with spoon - 7 153 204
Laboratory spatula, PA, Length 210 mm, with spoon, suitable for food
Half-Mask for protection against organic vapour inorganic & acid gases and particles - 7 302 062
Half-Mask for protection against organic vapour, inorganic & acid gases and particles, EN 405, FFA2P3DR
Clean bench WLC-V 1350/1700/2020 m²/h with HEPA Filter
Ideal for:
- protection of samples and work processes against dust and particulate contamination
Features:
- class 100 HEPA filter of efficiency up to 99.97% & 0.3 micron size (easy to exchange)
- mesh guard for HEPA filter protection
- vertical air flow-type
- optimized air flow system for uniform air flow/velocity
- 8 steps air velocity control
- UV and fluorescent lamp, external gas connection valve, internal electrical outlet
- silent and vibration-free blower (under 65 dB)
- corrosion resistant 304 stainless steel working table interior, powder-coated body and tempered safety glass sliding door for protection from UV radiation
- 99hr 59min timer
- high-quality backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- UV protection system: UV lamp is only activated when safety glass door is completely closed
Controller:
- microprocessor digital controller
- high performance touch input
Artikelliste
Order number | Model | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Filter | Ideal for | Connections | Illumination | Speed | Air volume |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WLCV1200 | WLC-V1200 230 V | 1200 mm | 660 mm | 610 mm | 1280 mm | 735 mm | 1895 mm | HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal | Protection of samples and work processes against dust and particulate contamination | 1 x air cock, 1 x gas cock, 2 x 230 V outlet | 1 x UV 20 W, 1 x FL 36 W | Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps | 1350 m2/h |
DH.WLCV1500 | WLC-V1500 230 V | 1500 mm | 660 mm | 610 mm | 1580 mm | 735 mm | 1895 mm | HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal | Protection of samples and work processes against dust and particulate contamination | 1 x air cock, 1 x gas cock, 2 x 230 V outlet | 1 UV 30 W, 1 x FL 55 W | Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps | 1700 m2/h |
DH.WLCV1800 | WLC-V1800 230 V | 1800 mm | 660 mm | 610 mm | 1880 mm | 735 mm | 1895 mm | HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal | Protection of samples and work processes against dust and particulate contamination | 1 x air cock, 1 x gas cock, 2 x 230 V outlet | 1 UV 30 W, 1 x FL 55 W | Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps | 2020 m2/h |
Vacuum pump Rocker 300 -680mmHg (106mbar) 25l/min - 00829 167300-22
Ideal for:
- filtration for microbiology test
- air sampling
- suspended solid test
- vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE, CSA and RoHs certified , IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 300 DC -650mmHg (146mbar) 25l/min - 00829 167330-00
Ideal for:
- filtration for microbiology test
- air sampling
- suspended solid test
- vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE and CSA certified
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 400 -680 mmHg (106 mbar) 34 l/min - 00829 167400-22
Ideal for:
- filtration for microbiology test
- air sampling
- suspended solid test
- vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE, CSA and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 410 -735 mmHg (33 mbar) 20 l/min - 00829 167410-22
Ideal for:
- filtration for microbiology test
- air sampling
- suspended solid test
- vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE, CSA and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 801 -670 mmHg (120 mbar) 68 l/min - 00829 167801-22
Ideal for:
- vacuum drying
- vacuum oven
- high volume degas
- high volume vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE certified
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 811 -735 mmHg (33 mbar) 40 l/min - 00829 167811-22
Ideal for:
- vacuum drying
- vacuum oven
- high volume degas
- high volume vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE certified
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Vacuum pump Rocker 430 -630 mmHg (173 mbar) 28 l/min 80 psi - 00829 167430-22
Ideal for:
- filtration for microbiology test
- air sampling
- suspended solid test
- vacuum filtration
Features:
- lubricant and oil free piston
- no air pollution
- maintenance-free
- ProteTM filter prevents liquid from being sucked into the pump and filters particles as well as moisture
- CE and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Compressor Rocker 320 80/100 psi 12 l/min - 00829 167320-22
Ideal for:
- aeration
- pressure filtration
Features:
- no air pollution
- maintenance-free
- quiet operation and low vibration
- direct driven motor
- air outlet filter device for filtering particles, moisture and supply clean air
- CE, CSA and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Compressor Rocker 420 80/100 psi 25 l/min - 00829 167420-22
Ideal for:
- aeration
- pressure filtration
Features:
- no air pollution
- maintenance-free
- quiet operation and low vibration
- direct driven motor
- air outlet filter device for filtering particles, moisture and supply clean air
- CE, CSA and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Air supply system Rocker 440 40-60 psi 25 l/min - 00829 167440-22
Ideal for:
- fermenter
- bioreactor
- gas chromatography
Features:
- no air pollution
- maintenance-free
- quiet operation and low vibration
- direct driven motor
- air outlet filter device for filtering particles, moisture and supply clean air
- CE, CSA and RoHs certified, with IP 30 protection
Controller:
- thermal protection device ensures shutting down the pump when overheated and resumes working when the temperature cooled down
Respirators with cool down valve - 7 302 030
Respirators, with cool down valve, acc. to EN 149 FFP1, solid aerosols Case = 12 pcs.
Respirators 3M EN 149 FFP3 SL - 7 302 033
Respirators 3M, EN 149 FFP3 SL, high poison dust and water - based, aerosols, standard size Pack = 10 pcs.
Vacuum pump pump speed: 100l/min - 2 600 033
Vacuum pump, pump speed: 100l/min, Ultimate Pressure Torr(Pa): 5x10-4 (6,7 x 10-2), Full load power: 0,4 kw, motor speed: 1700 rpm, oil capacity: 500 ml, ambient operation temp. range: 7°C - 40°C, overall dimensions (WxDxH): 150 x 392 x 250 mm, Power source: AC 230V 50/60Hz 2A, weight: 19 kg, CE-certified
Nylon syringe filter 0,45 µm Ø 25 mm - 8 214 100
Nylon syringe filter 0,45 µm Ø 25 mm, Case = 100 pcs.
Nylon syringe filter 0,22 µm Ø 25 mm - 8 214 101
Nylon syringe filter 0,22 µm Ø 25 mm, Case = 100 pcs.
Nylon syringe filter 0,45 µm Ø 25 mm - 8 214 102
Nylon syringe filter 0,45 µm Ø 25 mm, low extractables, Case = 100 pcs.
Nylon syringe filter 0,45 µm - 8 214 104
Nylon syringe filter 0,45 µm, Ø 13 mm, Case = 100 pcs.
Nylon syringe filter 0,20 µm - 8 214 105
Nylon syringe filter 0,20 µm, Ø 13 mm, low extractables, Case = 100 pcs.
Nylon syringe filter 0,45 µm Ø 25 mm - 8 214 111
Nylon syringe filter 0,45 µm Ø 25 mm, with glass prefilter and PP housing Case = 100 pcs.