The following products have been found matching your search "sc": 417

Close filters
  •  
    •  
    •  
    •  
    •  
    •  
    •  
from to
17 From 17
No results were found for the filter!
Micro Reaction Vials 1,0ml, brown - 9 358 103
Micro Reaction Vials 1,0ml, brown

 

Micro Reaction Vials, with Screw Cap, Amber Glass, Inner Bottom conical, outside Bottom grounded 1,0ml, 44 x 13 mm, Cap Size N-13, Pack = 12 pcs.

 

Micro Reaction Vials 2,0ml, brown - 9 358 104
Micro Reaction Vials 2,0ml, brown

 

Micro Reaction Vials, with Screw Cap, Amber Glass, Inner Bottom conical, outside Bottom grounded 2,0ml, 61 x 17 mm, Cap Size N-15, Pack = 12 pcs.

 

Micro Reaction Vials 3,0ml, brown - 9 358 105
Micro Reaction Vials 3,0ml, brown

 Micro Reaction Vials, with Screw Cap, Amber Glass, Inner Bottom conical, outside Bottom grounded 3,0ml, 55 x 21 mm, Cap Size N-20, Pack = 12 pcs.

 

Micro Reaction Vials 0,1ml, brown - 9 358 106
Micro Reaction Vials 0,1ml, brown

Micro Reaction Vials, with Screw Cap, Amber Glass, Inner Bottom conical, outside Bottom grounded 5,0ml, 64 x 21 mm, Cap Size N-20, Pack = 12 pcs

PP-waste bottle 4000ml, graduated, with overflow protection - 00829 167200-47
PP-waste bottle 4000ml, graduated, with overflow protection

PP-waste bottle 4000ml, graduated, with overflow protection and cover, 1/4 inch (6.5 mm)

Midi magnetic stirrer, 100 - 2,500 rpm, max. 5 l stirring capacity (H2O) - DH.STIM018
Midi magnetic stirrer, 100 - 2,500 rpm, max. 5 l stirring capacity (H2O)

 

Ideal for:

  • mixing of chemical, laboratory and pharmaceutical materials


Features:

  • high performance brushless DC-motor: high efficiency stirring performance and precise speed control (minimize RPM fluctuation), low maintenance costs
  • speed range from 100 – 2,500 rpm
  • max. 5 l stirring capacity (H2O)
  • outstanding chemical resistance due to tempered glass plate (180 x 180 mm) and PP housing
  • dust- and splashproof
  • digital speed LED display
  • suitable silicone pad included, to prevent the sample for moving during use
  • 30 mm stirrer bar included
  • CE certified and unique serial number for tracing


Controller:

  • electronically controlled motor for more capacity
  • digital PID control with Jog-Dial
PP-waste bottle 4000ml, graduated, with overflow protection and drain - 00829 167200-48
PP-waste bottle 4000ml, graduated, with overflow protection and drain

PP-waste bottle 4000ml, graduated, with overflow protection, drain and cover, 1/4 inch (6.5mm)

Mini magnetic stirrer, 100 - 2,500 rpm, max. 2 l stirring capacity (H2O) - DH.STIM012
Mini magnetic stirrer, 100 - 2,500 rpm, max. 2 l stirring capacity (H2O)

Ideal for:

  • mixing of chemical, laboratory and pharmaceutical materials


Features:

  • high performance brushless DC-motor: high efficiency stirring performance and precise speed control (minimize RPM fluctuation), low maintenance costs
  • speed range from 100 – 2,500 rpm
  • max. 2 l stirring capacity (H2O)
  • outstanding chemical resistance due to tempered glass plate (120 x 120 mm) and PP housing
  • dust- and splashproof
  • digital speed LED display
  • suitable silicone pad included, to prevent the sample for moving during use
  • 30 mm stirrer bar included
  • CE certified and unique serial number for tracing


Controller:

  • electronically controlled motor for more capacity
  • digital PID control with Jog-Dial
Spare screw caps, made of PP
Spare screw caps, made of PP
  • suitable for both narrow neck bottles and wide neck bottles
  • made from polypropylene
  • autoclavable
  • thread according to DIN 168
  • with small holes at the cap for safety tags to avoid sample contamination during transport
  • with inner cone for leak-proof closure

Artikelliste

Order number Model Color Thread Temperature range
7 172 318 Screw cap white GL 18 -40°C to +140°C
7 172 325 Screw cap white GL 25 -40°C to +140°C
7 172 332 Screw cap white GL 32 -40°C to +140°C
7 172 345 Screw cap white GL 45 -40°C to +140°C
7 172 363 Screw cap white GL 63 -40°C to +140°C
Thermal shaker WI1500-Pro - 6 000 400
Thermal shaker WI1500-Pro

Ideal for:

  • precise and efficient heating/cooling and mixing
  • many applications such as gene synthesis, gene purification, gene and protein denaturation, enzymatic reaction, bacterial growth and others

 

Features:

  • compact, programmable and with overheating protection for safe sample handling
  • precise temperature control for heating and cooling from  -5°C to +110°C for all major lab applications
  • interchangeable blocks for various applications, e.g. for reagent warming/cooling, DNA extractions, enzymatic reactions and reactions that need to processed at or near room temperature
  • fully programmable
  • precise temperature control for heating and cooling
  • real-time display of speed, temperature and time
  • excellent mixing (200-1500 rpm)
  • incl. 1 block for 96 well plates with lid
  • quick Interchange of blocks without tools and automatic block recognition
  • compatible with most popular tubes
  • block equipped with a lid for heat preservation
  • temperature self-calibration

 
Safety mechanism:

  • overheating protection at 150°C
Glass filtration set VF16 complete, 90mm, 1000ml - 00829 167200-10
Glass filtration set VF16 complete, 90mm, 1000ml

Glass filtration set VF16, 90 mm complete:
1000ml glass funnel,
anodized aluminium clamp, sintered glass support base with
silicone stopper No. 8, filtration adapter GL45,
5000ml glass bottle with thread GL45

Digital burette / bottle-top burette TITREX
Digital burette / bottle-top burette TITREX

The digital burette TITREX is ideal for a fast and sensitive titration “drop by drop”. One instrument simulates all volumes up to 99.99 ml. Moreover, titration is possible without any loss of reagent! From air-purging, necessary for a precise titration, to disassembly of the burette in the end of the titration – the reagent, that is not needed for the titration flows back into the bottle! TITREX‘s accuracy and precision are of highest quality. Our error ranges are better than those required by ISO 8655-3. The memory function allows saving of up to 1000 values, which can be transferred to a PC and read using the included software.

Your advantage at a glance:

  • high quality precision instrument, made in Germany
  • highest accuracy and precision, our error ranges are better than the DIN EN ISO 8655-3 requirements
  • resistant against most acids and alkalis
  • exclusive instrument with 0% loss of reagent - air-purging and draining within a closed circuit
  • 360° rotatable valve block for your added safety
  • two-in- one instrument: dosing & titration
  • covers the complete volume range up to 50 ml when used as a dispenser and up to 99.99 ml when used as a burette
  • easy and precise volume setting
  • vertical valves: no sedimentation, no contamination
  • 100 % drip-free by turning the cannula at 180°
  • no transcriptions errors due to automatic value storage and the possibility of
  • transferring values to a PC via RS232 interface (USB adapter optional available)
  • calibration: standard with water of 20°C
  • software enables saving the next calibration date
  • recalibration for liquids of different viscosities possible e.g. determination of acid content in milk
  • easy to dismantle and to clean, valve block autoclavable at 121°C
  • automatic power-cut-off after three minutes
  • including NiMH 1,2V 2100mAh battery
  • individual certificate, CE label and serial number
  • DE-M marked according to the German calibration law

Artikelliste

Order number Model Version Autoclavable Thread Systematic errors ISO Systematic errors witeg Random errors ISO Random errors witeg Volume Volume adjustment Accessories
5 497 050 TITREX premium premium Valve block at 121°C GL45 ±0.1 ml ±0.03 ml ≤0.05 ml ≤0.01 ml 0 - 50 ml Handwheels (left and right) incl. TITREXSOFT and RS232 interface cord
5 497 050 E TITREX eco eco Valve block at 121°C GL45 ±0.1 ml ±0.1 ml ≤0.05 ml ≤0.05 ml 0 - 50 ml Handwheels (left and right) TITREXSOFT and RS232 interface cord not included in the scope of supply
5 497 150 TITREX fine adjustment finely adjustable Valve block at 121°C GL45 ±0.1 ml ±0.03 ml ≤0.05 ml ≤0.01 ml 0 - 50 ml Handwheels (left and right) incl. TITREXSOFT and RS232 interface cord
witeg Safety caps GL 45 for HPLC
witeg Safety caps GL 45 for HPLC

High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.

The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.

witeg offers a cost-effective solution for this: the complete safety system suitable for all GL 45 laboratory bottles and more.

Artikelliste

Order number Model Ideal for Connections Accessories
8 257 201 blue OØ 1/8 inch tubing 2 ports -
8 257 202 blue OØ 1/8 inch tubing 3 ports -
8 257 203 red OØ 1/8 inch tubing 3 ports -
8 257 204 yellow OØ 1/8 inch tubing 4 ports -
8 257 205 blue OØ 1/16 inch tubing 2 ports -
8 257 206 red OØ 1/16 inch tubing 3 ports -
8 257 207 yellow OØ 1/16 inch tubing 4 ports -
8 257 217 black OØ 1/8 inch tubing 2 ports 1x air valve and 1 x 1/4’’-28 fitting
8 257 218 black OØ 1/8 inch tubing 3 ports 1x air valve and 2 x 1/4’’-28 fitting
8 257 219 black OØ 1/8 inch tubing 4 ports 1x air valve and 3 x 1/4’’-28 fitting
witeg Safety caps GLS 60 for HPLC, black - 8 257 220
witeg Safety caps GLS 60 for HPLC, black

High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.

The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.

witeg offers a cost-effective solution for this: the complete safety system suitable for all laboratory bottles and more.

Fittings for witeg Safety caps for HPLC
Fittings for witeg Safety caps for HPLC

High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.

The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.

witeg offers a cost-effective solution for this: the complete safety system suitable for all GL 45 laboratory bottles and more.

Artikelliste

Order number Model Thread Material Ideal for
8 257 208 natural 10-32unf OØ 1/16 inch tubing
8 257 209 natural 1/4-28 PEEK OØ 1/8 inch tubing
8 257 210 orange 1/4-28 PEEK OØ 1/8 inch tubing
8 257 211 dark blue 1/4-28 PP OØ 1/16 inch tubing
8 257 212 red 1/4-28 PP OØ 1/8 inch tubing
8 257 213 dark blue 1/4-28 PP OØ 1/8 inch tubing
8 257 214 natural 10-32unf PEEK blind plug
8 257 215 black 1/4-28 PP blind plug
witeg Safety caps GLS 80 for HPLC, blue - 8 257 280
witeg Safety caps GLS 80 for HPLC, blue

High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.

The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.

witeg offers a cost-effective solution for this: the complete safety system suitable for all laboratory bottles and more.

Winkler bottles for B.O.D. determination with glass stopper made of clear glass
Winkler bottles for B.O.D. determination with glass stopper made of clear glass
  • accurately adjusted
  • with glass stopper and label
  • made of clear glass

Artikelliste

Order number Model Diameter (outer) Color Material Capacity Diameter Height(outer)
2 911 100 Winkler bottles for B.O.D. determination 53 mm clear glass Glass 100 - 150 ml 53 mm 103 mm
2 911 250 Winkler bottles for B.O.D. determination 70 mm clear glass Glass 250 - 300 ml 70 mm 130 mm
2 911 500 Winkler bottles for B.O.D. determination 87 mm clear glass Glass 500 - 600 ml 87 mm 170 mm
17 From 17