The following products have been found matching your search "schutzschild": 21

Close filters
  •  
    •  
    •  
    •  
    •  
from to
No results were found for the filter!
Safety shields 630 x 550 mm - 7 302 901
Safety shields 630 x 550 mm
Safety shields, 630 x 550 mm, thickness 8 mm, made of acrylic glass, for safty in the laboratory, good stability and thick wall
Safety shields 450 x 250 x 600 mm - 7 302 916
Safety shields 450 x 250 x 600 mm
Safety shields, 450 x 250 x 600 mm, made of acrylic glass, for safty in the laboratory, good stability and thick wall
Clean bench WLC-V 1350/1700/2020 m²/h with HEPA Filter
Clean bench WLC-V 1350/1700/2020 m²/h with HEPA Filter

Ideal for:

  • protection of samples and work processes against dust and particulate contamination

 

Features:

  • class 100 HEPA filter of efficiency up to 99.97% & 0.3 micron size (easy to exchange)
  • mesh guard for HEPA filter protection
  • vertical air flow-type
  • optimized air flow system for uniform air flow/velocity
  • 8 steps air velocity control
  • UV and fluorescent lamp, external gas connection valve, internal electrical outlet
  • silent and vibration-free blower (under 65 dB)
  • corrosion resistant 304 stainless steel working table interior, powder-coated body and tempered safety glass sliding door for protection from UV radiation
  • 99hr 59min timer
  • high-quality backlight LCD display
  • CE certified and unique serial number for tracing

 

Safety mechanism:

  • UV protection system: UV lamp is only activated when safety glass door is completely closed

 

Controller:

  • microprocessor digital controller
  • high performance touch input

 

Artikelliste

Order number Model Width (inner) Length (inner) Height (inner) Width (Outer) Length (outer) Height (outer) Filter Ideal for Connections Illumination Speed Air volume
DH.WLCV1200 WLC-V1200 230 V 1200 mm 660 mm 610 mm 1280 mm 735 mm 1895 mm HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal Protection of samples and work processes against dust and particulate contamination 1 x air cock, 1 x gas cock, 2 x 230 V outlet 1 x UV 20 W, 1 x FL 36 W Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps 1350 m2/h
DH.WLCV1500 WLC-V1500 230 V 1500 mm 660 mm 610 mm 1580 mm 735 mm 1895 mm HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal Protection of samples and work processes against dust and particulate contamination 1 x air cock, 1 x gas cock, 2 x 230 V outlet 1 UV 30 W, 1 x FL 55 W Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps 1700 m2/h
DH.WLCV1800 WLC-V1800 230 V 1800 mm 660 mm 610 mm 1880 mm 735 mm 1895 mm HEPA filter: class 100, 0.3 μm particle removal 99.97%; pre-filter: 3-30 μm particle removal Protection of samples and work processes against dust and particulate contamination 1 x air cock, 1 x gas cock, 2 x 230 V outlet 1 UV 30 W, 1 x FL 55 W Air flow: 0.3 - 0.6 m/s, air velocity control: 8 steps 2020 m2/h
FREEZE DRYING AMPOULES W.MARKING AREA - 5 553 601
FREEZE DRYING AMPOULES W.MARKING AREA
FREEZE DRYING AMPOULES, W.MARKING AREA 1 ML, 10 X 155 MM
Respirators with cool down valve - 7 302 030
Respirators with cool down valve
Respirators, with cool down valve, acc. to EN 149 FFP1, solid aerosols Case = 12 pcs.
Respirators 3M EN 149 FFP3 SL - 7 302 033
Respirators 3M EN 149 FFP3 SL
Respirators 3M, EN 149 FFP3 SL, high poison dust and water - based, aerosols, standard size Pack = 10 pcs.
Half-Mask for protection against organic vapour inorganic & acid gases and particles - 7 302 062
Half-Mask for protection against organic vapour inorganic & acid gases and particles
Half-Mask for protection against organic vapour, inorganic & acid gases and particles, EN 405, FFA2P3DR
Full faceshield blue transparent PC - 7 302 201
Full faceshield blue transparent PC
Full faceshield, blue transparent PC, protecion 2, EN 166 faceshield 350 x 250 mm
Panoramic goggles frame colourless - 7 302 270
Panoramic goggles frame colourless
Panoramic goggles, frame colourless, lenses colourless PC 2 mm, for use on spectacles, with UV with protection 2-1.2 acc. to EN 166
Reams of filter paper 50 x 50 cm - 8 210 002
Reams of filter paper 50 x 50 cm
Reams of filter paper, 50 x 50 cm, thick paper Case = 500 pcs.
Reams of filter paper 320 x 420 mm - 8 210 010
Reams of filter paper 320 x 420 mm
Reams of filter paper, 320 x 420 mm, medium Case = 500 pcs.
Reams of filter paper 420 x 520 mm - 8 210 011
Reams of filter paper 420 x 520 mm
Reams of filter paper, 420 x 520 mm, medium Case = 500 pcs.
Reams of filter paper 500 x 500 mm - 8 210 012
Reams of filter paper 500 x 500 mm
Reams of filter paper, 500 x 500 mm, medium Case = 500 pcs.
Reams of filter paper 520 x 520 mm - 8 210 013
Reams of filter paper 520 x 520 mm
Reams of filter paper, 520 x 520 mm, medium Case = 500 pcs.
Reams of filter paper 580 x 580 mm - 8 210 014
Reams of filter paper 580 x 580 mm
Reams of filter paper, 580 x 580 mm, medium Case = 500 pcs.
Reams of filter paper 32 x 42 cm - 8 210 020
Reams of filter paper 32 x 42 cm
Reams of filter paper, 32 x 42 cm, fine Case = 500 pcs.
witeg Safety caps GL 45 for HPLC
witeg Safety caps GL 45 for HPLC

High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.

The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.

witeg offers a cost-effective solution for this: the complete safety system suitable for all GL 45 laboratory bottles and more.

Artikelliste

Order number Model Ideal for Connections Accessories
8 257 201 blue OØ 1/8 inch tubing 2 ports -
8 257 202 blue OØ 1/8 inch tubing 3 ports -
8 257 203 red OØ 1/8 inch tubing 3 ports -
8 257 204 yellow OØ 1/8 inch tubing 4 ports -
8 257 205 blue OØ 1/16 inch tubing 2 ports -
8 257 206 red OØ 1/16 inch tubing 3 ports -
8 257 207 yellow OØ 1/16 inch tubing 4 ports -
8 257 217 black OØ 1/8 inch tubing 2 ports 1x air valve and 1 x 1/4’’-28 fitting
8 257 218 black OØ 1/8 inch tubing 3 ports 1x air valve and 2 x 1/4’’-28 fitting
8 257 219 black OØ 1/8 inch tubing 4 ports 1x air valve and 3 x 1/4’’-28 fitting
witeg Safety caps GLS 60 for HPLC, black - 8 257 220
witeg Safety caps GLS 60 for HPLC, black

High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.

The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.

witeg offers a cost-effective solution for this: the complete safety system suitable for all laboratory bottles and more.

Fittings for witeg Safety caps for HPLC
Fittings for witeg Safety caps for HPLC

High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.

The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.

witeg offers a cost-effective solution for this: the complete safety system suitable for all GL 45 laboratory bottles and more.

Artikelliste

Order number Model Thread Material Ideal for
8 257 208 natural 10-32unf OØ 1/16 inch tubing
8 257 209 natural 1/4-28 PEEK OØ 1/8 inch tubing
8 257 210 orange 1/4-28 PEEK OØ 1/8 inch tubing
8 257 211 dark blue 1/4-28 PP OØ 1/16 inch tubing
8 257 212 red 1/4-28 PP OØ 1/8 inch tubing
8 257 213 dark blue 1/4-28 PP OØ 1/8 inch tubing
8 257 214 natural 10-32unf PEEK blind plug
8 257 215 black 1/4-28 PP blind plug
Air valve with lifetime display for witeg Safety caps for HPLC - 8 257 216
Air valve with lifetime display for witeg Safety caps for HPLC
  • for optimal protection against contamination
  • with 1/4" thread
  • with automatic lifetime indicator
  • 6 months usable from start
witeg Safety caps GLS 80 for HPLC, blue - 8 257 280
witeg Safety caps GLS 80 for HPLC, blue

High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.

The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.

witeg offers a cost-effective solution for this: the complete safety system suitable for all laboratory bottles and more.