The following products have been found matching your search "trennungen": 48
Ideal for:
- plasmid, DNA and RNA work, protein work, and miniprep kit, cell culture, cell harvesting, sub-cellular separations, and many other applications
Features:
- direct driven brushless DC motor, quiet operation (? 57 dB)
- air cooling system
- digital feedback speed control
- useful exclusive spin down function
- rotor lid for running and reducing noise
- realize extremely compact design with small footprint
- acceleration & braking times lower than 15 sec (max. speed)
- storage function for the set values: RPM & time
- simple operation for repetitive use of spin down function
- body made of ABS, rotor made of PE, lid made of PC
- backlight LCD display
- CE/GMP certified and unique serial number for tracing
Safety mechanism:
- safety system for motor error
- safety electronic lid lock system during running
Controller:
- digital feedback control with Jog-Shuttle-switch (turn + push)
Ideal for:
- DNA purification
- RNA purification
- gel purification
- PCR clean-up
Features:
- designed to replace traditional centrifuges with vacuum source to simplify purification process of:
- plasmid DNA
- single-stranded phage DNA, RNA
- genomic DNA
- viral nucleic acids from PCR
- other enzymatic reactions
- rapid continuous sample purification without centrifugation
- multi-use due to different adapter boards
- compatible with various kinds of centrifuge tubes and 96 well micro filter plates
Artikelliste
Order number | Model | Version | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Material | Ideal for | Connections | Pump performance |
---|---|---|---|---|---|---|---|---|---|---|---|---|
00829 195200-00 | WelVac 200 | unit only | 8.6 cm | 12.8 cm | 7.3 cm | 12.4 cm | 23.3 cm | 10.2 cm | Vacuum manifold: anodized aluminium; gasket: rubber; O-ring: rubber; column adaptor: PC; Luer connector: silicone; Luer stopper: silicone | DNA purification, RNA purification, gel purification, PCR clean-up | 5/16 inch (8 mm) | 23 l/min, -680 mmHg |
00829 195210-22 | Rocker 300 & WelVac 200 230 V | Rocker 300 230V, WelVac 200, disc filter, silicone tube (30 cm) | DNA purification, RNA purification, gel purification, PCR clean-up | 20 l/min, -680 mmHg |
Ideal for:
- designed for laboratory waste recovery and separation of liquid and solid
- can be widely used in cell culture, DNA extraction, micro plate waste removal, and any other liquid separation or recovery
Features:
- vacuum power can be set to different levels to achieve 1 ml/S to 15 ml/S aspiration speed (liquid 1 – 17 ml/S)
- sensitive level sensor to prevent liquid overflow during operation
- fully autoclavable waste collection bottle, tubing and handle.
- lid, tubing and handle are easy to disassemble, clean and autoclave
- wide range of adapters to fit tube, micro plate and disk plate for various tasks
- interchangeable hand operator – tip adapters make it suitable for various tasks from single channel to 8-channel based on the applications in tube, micro plate, disk plate, etc.
- including a hydrophobic filter 0.45 μm, Ø6 mm
- pump noise less than 65 dB (A)
- CE certified and unique serial number for tracing
Ideal for:
- centrifugation of temperature sensitive samples, such as live cells, animals or proteins
- can be used in multiple applications including:
- pelleting of DNA and RNA samples
- pelleting of PCR amplified nucleic acids
- separation of antibody and protein precipitates
- performing enzymatic tests
- removing cell debris from cell homogenates
- achieving bacterial and yeast cell fractionation
Features:
- electromagnetic door locking system; easy closing
- precooling: compressor automatically starts cooling if the set temperature is lower than the ambient temperature
- sound indicator at the end of running
- temperature range -20°C to +40°C
- short pre-cooling time: only 7 min. from room temperature to 4°C
- storage capacity for up to 9 programs
- 3-layer sealed rotors ensure safe centrifugation
- high-strength aluminum alloy rotor, fully autoclavable at 121°C
- acceleration/deceleration in 9 steps; gentle braking at low speed for better separation
- five rotors with 0.2 ml, 0.5 ml, 1.5 ml, 2 ml and 5 ml centrifuge tubes/ PCR tubes capacity
- external condensation tank prevents water accumulation within centrifuge chamber
- brushless DC motor
- rotation speed/RCF switchover
- inching operation
- running process indicator
- sound alert
- program storage capacity
- CE cTÜVus FCC certified
Safety mechanism:
- rotor imbalance detection alarm
- dual door lock
- over-speed detection
- over-temperature detection with internal diagnosis system
Ideal for:
- separation of whole blood components such as serum, plasma, buffy coat, red blood cells, as well as other bodily fluids
Features:
- easy operation with intuitive menu and easy-to-read display
- speed can be set in rpm/RCF
- maintenance-free brushless DC motor
- quick spin function with press and hold pulse key
- lid with electric lock and automatic lid-lock release after running
- braking time 2 steps adjustable only for CF6-50P rotor
- high strength plastic rotor gives excellent balance to guarantee stable working
- dual protection housing for particularly safe running
- gentle braking at low speeds with efficient separation
- speed/RCF switch
- short-time run function
- sound-alert function
- CE marked, cTÜVus and passed explosion-proof test
Safety devices:
- door interlock
- over speed detector
- automatic internal diagnosis
Artikelliste
Order number | Model | Version | Width (Outer) | Length (outer) | Height (outer) | Power supply | Speed | Rotor |
---|---|---|---|---|---|---|---|---|
6 000 190 | CF4500 | Max. RCF 2490xg | 354 mm | 304 mm | 215 mm | single-phase,100V-240V, 50Hz/60Hz, 3A70W | 300-4500 rpm, increment: 100 rpm, accuracy ±20 rpm, Acceleration/Braking time: 20s↑ 13s↓ | CF12-10P |
6 000 195 | CF4550 | Max. RCF 2490xg | 354 mm | 304 mm | 215 mm | single-phase,100V-240V, 50Hz/60Hz, 3A70W | 300-4500 rpm, increment: 100 rpm, accuracy ±20 rpm, Acceleration/Braking time: 20s↑ 20 s/190 s ↓ | CF6-50P |
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all GL 45 laboratory bottles and more.
Artikelliste
Order number | Model | Ideal for | Connections | Accessories |
---|---|---|---|---|
8 257 201 | blue | OØ 1/8 inch tubing | 2 ports | - |
8 257 202 | blue | OØ 1/8 inch tubing | 3 ports | - |
8 257 203 | red | OØ 1/8 inch tubing | 3 ports | - |
8 257 204 | yellow | OØ 1/8 inch tubing | 4 ports | - |
8 257 205 | blue | OØ 1/16 inch tubing | 2 ports | - |
8 257 206 | red | OØ 1/16 inch tubing | 3 ports | - |
8 257 207 | yellow | OØ 1/16 inch tubing | 4 ports | - |
8 257 217 | black | OØ 1/8 inch tubing | 2 ports | 1x air valve and 1 x 1/4’’-28 fitting |
8 257 218 | black | OØ 1/8 inch tubing | 3 ports | 1x air valve and 2 x 1/4’’-28 fitting |
8 257 219 | black | OØ 1/8 inch tubing | 4 ports | 1x air valve and 3 x 1/4’’-28 fitting |
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all laboratory bottles and more.
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all GL 45 laboratory bottles and more.
Artikelliste
Order number | Model | Thread | Material | Ideal for |
---|---|---|---|---|
8 257 208 | natural | 10-32unf | OØ 1/16 inch tubing | |
8 257 209 | natural | 1/4-28 | PEEK | OØ 1/8 inch tubing |
8 257 210 | orange | 1/4-28 | PEEK | OØ 1/8 inch tubing |
8 257 211 | dark blue | 1/4-28 | PP | OØ 1/16 inch tubing |
8 257 212 | red | 1/4-28 | PP | OØ 1/8 inch tubing |
8 257 213 | dark blue | 1/4-28 | PP | OØ 1/8 inch tubing |
8 257 214 | natural | 10-32unf | PEEK | blind plug |
8 257 215 | black | 1/4-28 | PP | blind plug |
High performance liquid chromatography (HPLC) is a biochemical analysis method used to separate, identify and quantify substances in a mixture. Compared to simple column chromatography, HPLC separates the mixture of substances under pressure and possibly also under the influence of temperature with the help of two phases, a stationary and a mobile phase, faster and more precisely.
The mobile phase consists of solvents that are withdrawn from storage bottles. For reliable results without contamination from the environment on the one hand and to protect the user from solvent vapors on the other hand, it is necessary for these bottles to be equipped with special safety caps.
witeg offers a cost-effective solution for this: the complete safety system suitable for all laboratory bottles and more.
Simultan separating chamber, for TLC-plates
200 x 200 mm, with ground rim and ground flat glass lid,
with vertical grooves in the transverse wall to hold
5 TLC plates, made of soda glass, complete
Nano separating chambers, ground rim,
for TLC plates up to 100/100mm, with knobbed lid,
made of soda glass