Spare screw caps, made of PP
- suitable for both narrow neck bottles and wide neck bottles
- made from polypropylene
- autoclavable
- thread according to DIN 168
- with small holes at the cap for safety tags to avoid sample contamination during transport
- with inner cone for leak-proof closure
Artikelliste
Order number | Model | Color | Thread | Temperature range |
---|---|---|---|---|
7 172 318 | Screw cap | white | GL 18 | -40°C to +140°C |
7 172 325 | Screw cap | white | GL 25 | -40°C to +140°C |
7 172 332 | Screw cap | white | GL 32 | -40°C to +140°C |
7 172 345 | Screw cap | white | GL 45 | -40°C to +140°C |
7 172 363 | Screw cap | white | GL 63 | -40°C to +140°C |
Bottle-top dispenser LABMAX eco
Dispensing with LABMAX eco is both economic and environmental friendly. This standard-dispenser is usable for nearly all applications of dispensing liquids in the lab and is especially ECOnomically priced. Use the “recycling mode” for an ECOlogical air-purging and draining without any loss of reagent!
Your advantage at a glance:
- high quality precision instrument, made in Germany
- all-purpose dispenser, universal chemical compatibility
- highest accuracy and precision, our error ranges are better than the DIN EN ISO 8655-5 requirements
- most affordable price in its class
- direct displacement piston system, ideal for crystalline solutions
- robust and stable, made of high quality materials e.g. platinum springs
- 0% loss of reagent by pumping in a closed circuit
- 100% drip-free due to our unique anti-drip system
- 360° rotatable valve block for added safety
- one handed operation
- flexible by using different bottle adapters
- easy to clean, completely autoclavable at 121°C
- 250ml dispenser available
- individual certificate and serial number
- DE-M marked according to the German calibration law
Artikelliste
Order number | Model | Thread | Systematic errors ISO | Numeric division | Random errors ISO | Volume | Volume adjustment |
---|---|---|---|---|---|---|---|
5 370 001 | LABMAX eco 0.25 - 2.5 ml | GL32 | ±0.012 ml | 0.05 ml | ≤0.002 ml | 0.25 - 2.5 ml | Adjustment knob |
5 370 002 | LABMAX eco 0.5 - 5 ml | GL32 | ±0.03 ml | 0.1 ml | ≤0.005 ml | 0.5 - 5.0 ml | Adjustment knob |
5 370 003 | LABMAX eco 1 - 10 ml | GL32 | ±0.06 ml | 0.2 ml | ≤0.01 ml | 1.0 - 10.0 ml | Adjustment knob |
5 370 004 | LABMAX eco 2.5 - 25 ml | GL45 | ±0.15 ml | 0.5 ml | ≤0.025 ml | 2.5 - 25.0 ml | Adjustment knob |
5 370 005 | LABMAX eco 5 - 50 ml | GL45 | ±0.3 ml | 1 ml | ≤0.05 ml | 5.0 - 50.0 ml | Adjustment knob |
5 370 006 | LABMAX eco 10 - 100 ml | GL45 | ±0.5 ml | 2 ml | ≤0.1 ml | 10.0 - 100.0 ml | Adjustment screw |
5 370 007 OE | LABMAX eco 25 - 250 ml | GL45 | ±1.2 ml | 5 ml | ≤0.25 ml | 25.0 - 250.0 ml | Adjustment screw |
Thermal cycler Wi-TC1000-G/-S, heating range 4°C - 105°C, standard or gradient
Ideal for:
- molecular biology with applications such as sequening, gene cloning, gene expression, mutagensis
- also in areas such as drug discovery, agriculture, food industry, etc.
Features:
- high performance peltier and independent heating segments improving temperature control
- auxiliary heating mechanism diminishes the “edge effect” and enhance the temperature uniformity
- wide touchdown PCR temperature range (-9.9°C to +9.9°C) and long PCR time range (-9min 59s to +9min 59s)
- gradient temperature setting optimizes temperature easily in the single run (Wi-TC1000-G only)
- 7" LCD-colortouch, 800 x 480, screen with user friendly interface helps to edit programs easliy
- wide options of consumables: common PCR tubes, 8-well PCR strips and 96-well PCR plates can be used
- user defined file system: max. 30 segments with 99 cycles, max. 16 folder and16 files each folder
Safety mechanism:
- with power off protection, automatic program recovery
- hot Iid auto-off function at 30°C - 110°C: lf module temperature is lower than 30°C, the hot Iid function will automatically tum off
Artikelliste
Order number | Model | Version | Width (Outer) | Length (outer) | Height (outer) | Material | Power supply | Cooling time | Heating time | Capacity | Temperature variation | Temperature range | Temperature accuracy |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 000 600 | Wi-TC1000-S | Standard | 280 mm | 370 mm | 250 mm | Adapter block material: aluminum | 100V - 120V/200V - 240V, 50/60Hz | 5°C/sec | 5°C/sec | 96 x 0.2 ml PCR tubes, 8 x 12 PCR plate or 96 well plate | at 55°C <0.3°C | 4°C - 105°C | ±0.1°C, at 55°C ±0.3°C |
6 000 500 | Wi-TC1000-G | gradient, gradient temperature setting range: 30°C - 99°C, Gradient range: 1°C - 42°C | 280 mm | 370 mm | 250 mm | Adapter block material: aluminum | 100V - 120V/200V - 240V, 50/60Hz | 5°C/sec | 5°C/sec | 96 x 0.2 ml PCR tubes, 8 x 12 PCR plate or 96 well plate | at 55°C <0.3°C | 4°C - 105°C | ±0.1°C, at 55°C ±0.3°C |