No results were found for the filter!
Incubators WIM industrial 4 chambers each 125 Liter
Ideal for:
- microorganism culture, animal and plant cell culture, constant temperature, germination, etc.
Features:
- forced-air flow by silent fan motor implements the highest uniformity of temperature in each chamber
- 4x125 liter chambers
- each chamber has an independent fuzzy controller for different temperature and time control
- 8x PE-coated steel wire shelves included
- corrosion resistant stainless steel chamber, powder-coated body
- tempered glass door to observe samples during incubation
- storage function for the set values of temperature and timer
- backlight LCD display
- CE & UL/CUL certified and unique serial number for tracing
Safety mechanism:
- locking mode
- overheat and over-current protection
- sensor error detection
Controller:
- digital fuzzy controller with Jog-Shuttle-switch (turn + push)
Artikelliste
Order number | Model | Version | Width (Outer) | Length (outer) | Height (outer) | Heating time | Illumination | Shelves | Heating power | Capacity | Compressor | Effective space | Power consumption | Temperature variation | Temperature range | Temperature accuracy | Recovery time | Sensor |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WIM04125 | WIM-4 230 V | 4 individual chambers, forced-air convection | 1655 mm | 845 mm | 1710 mm | 15 min. to 37°C, 30 min. to 50°C | 8 PE-coated steel wire shelves included | 4 x 500 W | 4 chambers x 125 l | 500 x 500 x 500 mm (each room) | 2600 W | ±0.3°C at 37°C, ±0.7°C at 50°C | Room temperature +5°C - 70°C | ±0.2°C to 37°C | 8 min. to 37°C, 10 min. to 50°C | Temperature sensor PT100 | ||
DH.WIM14125 | WIM-R4 230 V | 4 individual chambers, forced-air convection, not available in Europe | 1655 mm | 845 mm | 1710 mm | 20 min. to 37°C, 30 min. to 50°C | 8 PE-coated steel wire shelves included | 4 x 650 W | 4 chambers x 125 l | 1/4 HP (4 x chambers) | 500 x 500 x 500 mm (each room) | 4500 W | ±0.5°C at 37°C | 0°C - 60°C (refrigerated) | ±0.2°C to 37°C | 10 min. to 37°C, 12 min. to 50°C | Temperature sensor PT100 | |
DH.WIM24125 | WIM-RL4 230 V | 4 individual chambers, forced-air convection, not available in Europe | 1655 mm | 845 mm | 1710 mm | 20 min. to 37°C, 30 min. to 50°C | 2 x FRL 55 W (x 4 chambers) | 8 PE-coated steel wire shelves included | 4 x 650 W | 4 chambers x 125 l | 1/4 HP (4 x chambers) | 500 x 500 x 500 mm (each room) | 4800 W | ±0.5°C at 37°C | 0°C - 60°C (refrigerated) | ±0.2°C to 37°C | 10 min. to 37°C, 12 min. to 50°C | Temperature sensor PT100 |
DH.WIM16125 | WIM-R4 3 Phase | 4 individual chambers, forced-air convection | 1655 mm | 845 mm | 1710 mm | 20 min. to 37°C, 30 min. to 50°C | 8 PE-coated steel wire shelves included | 4 x 650 W | 4 chambers x 125 l | 1/4 HP (4 x chambers) | 500 x 500 x 500 mm (each room) | 4500 W | ±0.5°C at 37°C | 0°C - 60°C (refrigerated) | ±0.2°C to 37°C | 10 min. to 37°C, 12 min. to 50°C | Temperature sensor PT100 | |
DH.WIM26125 | WIM-RL4 3 Phase | 4 individual chambers, forced-air convection | 1655 mm | 845 mm | 1710 mm | 20 min. to 37°C, 30 min. to 50°C | 2 x FRL 55 W (x 4 chambers) | 8 PE-coated steel wire shelves included | 4 x 650 W | 4 chambers x 125 l | 1/4 HP (4 x chambers) | 500 x 500 x 500 mm (each room) | 4800 W | ±0.5°C at 37°C | 0°C - 60°C (refrigerated) | ±0.2°C to 37°C | 10 min. to 37°C, 12 min. to 50°C | Temperature sensor PT100 |
Thermal cycler Wi-TC1000-G/-S, heating range 4°C - 105°C, standard or gradient
Ideal for:
- molecular biology with applications such as sequening, gene cloning, gene expression, mutagensis
- also in areas such as drug discovery, agriculture, food industry, etc.
Features:
- high performance peltier and independent heating segments improving temperature control
- auxiliary heating mechanism diminishes the “edge effect” and enhance the temperature uniformity
- wide touchdown PCR temperature range (-9.9°C to +9.9°C) and long PCR time range (-9min 59s to +9min 59s)
- gradient temperature setting optimizes temperature easily in the single run (Wi-TC1000-G only)
- 7" LCD-colortouch, 800 x 480, screen with user friendly interface helps to edit programs easliy
- wide options of consumables: common PCR tubes, 8-well PCR strips and 96-well PCR plates can be used
- user defined file system: max. 30 segments with 99 cycles, max. 16 folder and16 files each folder
Safety mechanism:
- with power off protection, automatic program recovery
- hot Iid auto-off function at 30°C - 110°C: lf module temperature is lower than 30°C, the hot Iid function will automatically tum off
Artikelliste
Order number | Model | Version | Width (Outer) | Length (outer) | Height (outer) | Material | Power supply | Cooling time | Heating time | Capacity | Temperature variation | Temperature range | Temperature accuracy |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 000 600 | Wi-TC1000-S | Standard | 280 mm | 370 mm | 250 mm | Adapter block material: aluminum | 100V - 120V/200V - 240V, 50/60Hz | 5°C/sec | 5°C/sec | 96 x 0.2 ml PCR tubes, 8 x 12 PCR plate or 96 well plate | at 55°C <0.3°C | 4°C - 105°C | ±0.1°C, at 55°C ±0.3°C |
6 000 500 | Wi-TC1000-G | gradient, gradient temperature setting range: 30°C - 99°C, Gradient range: 1°C - 42°C | 280 mm | 370 mm | 250 mm | Adapter block material: aluminum | 100V - 120V/200V - 240V, 50/60Hz | 5°C/sec | 5°C/sec | 96 x 0.2 ml PCR tubes, 8 x 12 PCR plate or 96 well plate | at 55°C <0.3°C | 4°C - 105°C | ±0.1°C, at 55°C ±0.3°C |