Ideal for:
- connection with evaporator
Features:
- stainless steel bath, polyurethane insulation of 40 mm thickness and body made of powder-coated steel
- innovated refrigeration system ensures temperature performance, includes intelligent control for preventing compressor overload, CFC-free (R-404A)
- innovated powerful circulation pump ensures temperature uniformity: internal and external circulation and 5 steps circulation speed
- stainless steel flat lid & valve ball included, dome lid optional
- RS232C interface: remote monitoring and controlling with PC
- proper liquid level tag in bath
- user‘s self-compensation function to control difference between real temperature and indicated temperature (±10.0°C)
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- overheat and over-current protection
- sensor error detection and leakage breaker
- low liquid level warning and automatic stop function
- locking mode
Controller:
- digital fuzzy controller with Jog-Dial-switch (turn + push) & capacitive touch button
Artikelliste
Order number | Model | Width (inner) | Length (inner) | Height (inner) | Width (Outer) | Length (outer) | Height (outer) | Ideal for | Connections | Pressure | Heating power | Capacity | Effective space | Pump performance | Temperature variation | Temperature control resolution | Temperature range | Temperature accuracy | Packing size | Refrigerator | Cooling capacity | Sensor | Flow rate |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH.WCL00408 | WCL-8 230 V | 175 mm | 320 mm | 150 mm | 400 mm | 523 mm | 807 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 1000 W | 8 l | 175 x 153 x 150 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -20°C | Display 0.1°C, control 0.1°C | -35°C - +150°C | ±0.1°C | 630 x 530 x 972 mm | 370 W | 500 W at +20°C, 340 W at 0°C, 200 W at -20°C | Temperature sensor PT100 | 25l/Min. |
DH.WCL00412 | WCL-12 230 V | 230 mm | 350 mm | 150 mm | 400 mm | 523 mm | 807 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 1500 W | 12 l | 230 x 181 x 150 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -20°C | Display 0.1°C, control 0.1°C | -35°C - +150°C | ±0.1°C | 630 x 530 x 972 mm | 370 W | 530 W at +20°C, 370 W at 0°C, 210 W at -20°C | Temperature sensor PT100 | 25l/Min. |
DH.WCL00422 | WCL-22 230 V | 290 mm | 390 mm | 200 mm | 483 mm | 563 mm | 850 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 2000 W | 22 l | 290 x 220 x 200 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -20°C | Display 0.1°C, control 0.1°C | -35°C - +150°C | ±0.1°C | 670 x 615 x 1022 mm | 650 W | 860 W at +20°C, 620 W at 0°C, 400 W at -20°C | Temperature sensor PT100 | 25l/Min. |
DH.WCL00430 | WCL-30 230 V | 330 mm | 460 mm | 200 mm | 494 mm | 633 mm | 906 mm | Connection with evaporator | External circulation nozzle: inner: Ø10.5mm, outer Ø12.5mm, for inner circulating: connect directly the in-/outlet nozzles | 7.5 psi | 2200 W | 30 l | 330 x 290 x 200 mm | 25 l/min., max. lift: 4 m | ±0.2°C to -20°C | Display 0.1°C, control 0.1°C | -35°C - +150°C | ±0.1°C | 740 x 625 x 1072 mm | 750 W | 1030 W at +20°C, 760 W at 0°C, 500 W at -20°C | Temperature sensor PT100 | 25l/Min. |
Ideal for:
- multi-use digital precise immersion circulator head
Features:
- user‘s self-compensation function to control difference between real temperature and indicated temperature (±10.0°C)
- digital timer function (99hr 59min): delay time and operation time can be controlled
- powerful circulation pump assures temperature uniformity
- storage function for the set values of temperature and timer
- backlight LCD display
- CE certified and unique serial number for tracing
Safety mechanism:
- locking mode
- over- temperature and over-current protection
- sensor error detection
- low water level warning and automatic stop function
Controller:
- digital fuzzy controller with Jog-Shuttle-switch (turn + push)
Artikelliste
Order number | Model | Width (Outer) | Length (outer) | Height (outer) | Capacity | Pump performance | Power consumption | Temperature range | Temperature accuracy | Packing size | Sensor |
---|---|---|---|---|---|---|---|---|---|---|---|
DH.WCB10011 | WCB-11H 230 V | 130 mm | 165 mm | 320 mm | 11 l | 5 l/min | 1000 W | Room temperature +5°C - 100°C | ±0.1°C | 400 x 280 x 200 mm | Temperature sensor PT100 |
DH.WCB10022 | WCB-22H 230 V | 130 mm | 165 mm | 320 mm | 22 l | 5 l/Min | 2000 W | Raumtemperatur +5°C - 100°C | ±0,1°C | 400 x 280 x 200 mm | Temperatursensor PT100 |
Ideal for:
- cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency
Features:
- made of stainless steel, finished surface
- convenient preset function of heating and timer
- HF frequency 40 kHz
- bottom-mounted drain valve (WUC-A10H and WUC-A22H)
- maximum 30 minutes cleaning time
- CE certified and unique serial number for tracing
Controller:
- analog controller for timer, temperature and output control
Artikelliste
Order number | Model | Version | Ideal for | Drain valve | Vessel diameter | Heating power | Capacity | Power consumption | Temperature range | Ultrasound | Packing size |
---|---|---|---|---|---|---|---|---|---|---|---|
DH.WUC.A01H | WUC-A01H 230 V | with flip switch | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 150 x 135 x 60 mm | 86 W | 1.2 l | 158 W | ambient or 65°C fix | HF-peak-out: 72 W | 200 x 200 x 190 mm | |
DH.WUC.A02H | WUC-A02H 230 V | with flip switch | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 150 x 135 x 100 mm | 86 W | 1.8 l | 161 W | ambient or 65°C fix | HF-peak-out: 75 W | 200 x 200 x 240 mm | |
DH.WUC.A03H | WUC-A03H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 240 x 140 x 100 mm | 172 W | 3.3 l | 296 W | Ambient to 85°C | HF-peak-out: 124 W | 320 x 200 x 290 mm | ||
DH.WUC.A06H | WUC-A06H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 290 x 150 x 150 mm | 172 W | 6 l | 340 W | Ambient to 85°C | HF-peak-out: 168 W | 370 x 220 x 350 mm | ||
DH.WUC.A10H | WUC-A10H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 1/2“ NPT | 290 x 240 x 150 mm | 258 W | 10 l | 523 W | Ambient to 85°C | HF-peak-out: 265 W | 434 x 320 x 360 mm | |
DH.WUC.A22H | WUC-A22H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 1/2“ NPT | 500 x 300 x 150 mm | 275 W | 22 l | 654 W | Ambient to 85°C | HF-peak-out: 379 W | 640 x 380 x 370 mm |
Ideal for:
- cleaning to remove dirt, grease, waxes and oil from all laboratory instruments by ultrasonic frequency
Features:
- convenient preset function of heating and timer
- HF frequency 40 kHz
- temperature range from ambient to 80°C
- bottom-mounted drain valve (WUC-D10H and WUC-D22H)
- maximum 60 minutes cleaning time
- microprocessor control: timer, temperature and output control
- FND display
- CE certified and unique serial number for tracing
- WUC-D03H model includes degassing function for very strong cleansing
Controller:
- digital controller for timer, temperature and output control
Artikelliste
Order number | Model | Ideal for | Drain valve | Vessel diameter | Heating power | Capacity | Power consumption | Temperature range | Ultrasound | Packing size |
---|---|---|---|---|---|---|---|---|---|---|
DH.WUC.D03H | WUC-D03H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 240 x 140 x 100 mm | 172 W | 3.3 l | 290 W | Ambient to 80°C | HF-peak-out: 100 W | 320 x 200 x 290 mm | |
DH.WUC.D06H | WUC-D06H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 290 x 150 x 150 mm | 172 W | 6 l | 425 W | Ambient to 80°C | HF-peak-out: 253 W | 360 x 220 x 350 mm | |
DH.WUC.D10H | WUC-D10H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 1/2“ NPT | 290 x 240 x 150 mm | 258 W | 10 l | 665 W | Ambient to 80°C | HF-peak-out: 407 W | 440 x 320 x 360 mm |
DH.WUC.D22H | WUC-D22H 230 V | Cleaning to remove dirt, grease, waxes and oil from all lab instruments by ultrasonic frequency | 1/2“ NPT | 500 x 300 x 150 mm | 344 W | 22 l | 872 W | Ambient to 80°C | HF-peak-out: 528 W | 640 x 380 x 370 mm |
Pipette rack for "Witopet EP" with 5 places
Rolled neck bottles 25 ml, neck Ø 22 mm, O.Ø. 30 mm, height 50 mm, clear glass Case = 200 pcs.
Rolled neck bottles 35 ml, neck Ø 22 mm, O.Ø. 30 mm, height 65 mm, clear glass Case = 200 pcs.
Rolled neck bottles 40 ml, neck Ø 22 mm, O.Ø. 30 mm, height 80 mm, clear glass Case = 200 pcs.
Rolled neck bottles 50 ml, neck Ø 22 mm, O.Ø. 30 mm, height 100 mm, clear glass Case = 200 pcs.
Rolled neck bottles 100 ml, neck Ø 22 mm, O.Ø. 34 mm, height 145 mm, clear glass Case = 100 pcs.
Haemacytometer-cover glasses, 22 x 22 mm, thickn. 0,4 mm, not tested (only exportation), opt. plane ground surface, polished, Pack = 10 pcs.